9 research outputs found

    Spatial Correction Improves Accuracy of Catheter Positioning During Ablation of Premature Ventricular Contractions: Differences Between Ventricular Outflow Tracts And Other Localizations.

    No full text
    Abstract 1.1. PurposeHybrid activation mapping is a novel tool to correct for spatial displacement of the mapping catheter due to asymmetrical contraction of myocardium during premature ventricular contractions (PVC). The aim of this study is to describe the extent and cause of spatial displacement during PVC mapping and options for correction using hybrid activation mapping. 1.2. Methods and ResultsWe analyzed 5798 hybrid mapping points in 40 acquired hybrid maps of 22 consecutive patients (age 63±16 years, 45% female) treated for premature ventricular contractions (PVCs). Median PVC-coupling interval was 552 ms (IQR 83 ms). Spatial displacement was determined by measuring the dislocation of the catheter tip during PVC compared to the preceding sinus beat. Mean spatial displacement was 3.8±1.5 mm for all maps. The displacement was 1.3±0.4 mm larger for PVCs with non-outflow-tract origin compared to PVCs originating from the ventricular outflow tracts (RVOT/LVOT; p=0.028). Demographic parameters, PVC-coupling-interval and chamber of origin had no significant influence on the extent of spatial displacement. 1.3. ConclusionEctopic activation of the ventricular myocardium during PVCs results in spatial displacement of mapping points that is significantly larger for PVCs with non-outflow-tract origin. The correction for spatial displacement may improve accuracy of radiofrequency current (RFC)-application in catheter ablation of PVCs.</jats:p

    Long-term efficacy and safety of radiofrequency catheter ablation of atrial fibrillation in patients with cardiac implantable electronic devices and transvenous leads

    No full text
    Introduction Long-term efficacy and safety are uncertain in patients with cardiac implantable electronic devices (CIED) and transvenous leads (TVL) undergoing radiofrequency catheter ablation of atrial fibrillation (AF). Thus, we assessed the outcome of AF ablation in those patients during long-term follow-up using continuous atrial rhythm monitoring (CARM). Methods and Results A total of 190 patients (71.3 +/- 10.7 years; 108 (56.8% men) were included in this study. At index procedure 81 (42.6%) patients presented with paroxysmal AF and 109 (57.4%) with persistent AF. The ablation strategy included pulmonary vein isolation in all patients and biatrial ablation of complex fractionated electrograms with additional ablation lines, if appropriate. AF recurrences were assessed by CARM- and CIED-related complications by device follow-up. After a mean follow-up of 55.4 +/- 38.1 months, freedom of AF was found in 86 (61.4%) and clinical success defined as an AF burden less than or equal to 1% in 101 (72.1%) patients. Freedom of AF was reported in 74.6% and 51.9% (P = 0.006) and clinical success in 89.8% and 59.3% (P < 0.001) of patients with paroxysmal and persistent AF, respectively. In 3 of 408 (0.7%) ablation procedures, a TVL malfunction occurred within 90 days after catheter ablation. During long-term follow-up 9 (4.7%) patients showed lead dislodgement, 2 (1.1%) lead fracture, and 2 (1.1%) lead insulation defect not related to the ablation procedure. Conclusion Our findings using CARM demonstrate long-term efficacy and safety of radiofrequency catheter ablation of AF in patients with CIED and TVL

    Analysis of Outcomes in Ischemic vs Nonischemic Cardiomyopathy in Patients With Atrial Fibrillation A Report From the GARFIELD-AF Registry

    No full text
    IMPORTANCE Congestive heart failure (CHF) is commonly associated with nonvalvular atrial fibrillation (AF), and their combination may affect treatment strategies and outcomes
    corecore