378 research outputs found

    Handling Package Bees

    Get PDF
    PDF pages: 1

    Chandra Observations of SN 2004et and the X-ray Emission of Type IIp Supernovae

    Full text link
    We report the X-ray detection of the Type II-plateau supernova SN 2004et in the spiral galaxy NGC 6946, using the Chandra X-Ray Observatory. The position of the X-ray source was found to agree with the optical position within ~0.4 arcsec. Chandra also surveyed the region before the 2004 event, finding no X-ray emission at the location of the progenitor. For the post-explosion observations, a total of 202, 151, and 158 photons were detected in three pointings, each ~29 ks in length, on 2004 October 22, November 6, and December 3, respectively. The spectrum of the first observation is best fit by a thermal model with a temperature of kT=1.3 keV and a line-of-sight absorption of N_H=1.0 x 10^{22} cm^{-2}. The inferred unabsorbed luminosity (0.4-8 keV) is ~4x10^{38} erg/s, adopting a distance of 5.5 Mpc. A comparison between hard and soft counts on the first and third epochs indicates a softening over this time, although there is an insufficient number of photons to constrain the variation of temperature and absorption by spectral fitting. We model the emission as arising from the reverse shock region in the interaction between the supernova ejecta and the progenitor wind. For a Type IIP supernova with an extended progenitor, the cool shell formed at the time of shock wave breakout from the star can affect the initial evolution of the interaction shell and the absorption of radiation from the reverse shock. The observed spectral softening might be due to decreasing shell absorption. We find a pre-supernova mass loss rate of (2-2.5)x 10^{-6} M_{\odot} /yr for a wind velocity of 10 kms, which is in line with expectations for a Type IIP supernova.Comment: total 19 pages including 7 figures. ApJ, in press. See http://spider.ipac.caltech.edu/staff/rho/preprint/SN2004etms.ps for the paper including full resolution image

    High Altitude test of RPCs for the ARGO-YBJ experiment

    Get PDF
    A 50 m**2 RPC carpet was operated at the YangBaJing Cosmic Ray Laboratory (Tibet) located 4300 m a.s.l. The performance of RPCs in detecting Extensive Air Showers was studied. Efficiency and time resolution measurements at the pressure and temperature conditions typical of high mountain laboratories, are reported.Comment: 16 pages, 10 figures, submitted to Nucl. Instr. Met

    Observation of TeV gamma-rays from the unidentified source HESS J1841-055 with the ARGO-YBJ experiment

    Get PDF
    We report the observation of a very high energy \gamma-ray source, whose position is coincident with HESS J1841-055. This source has been observed for 4.5 years by the ARGO-YBJ experiment from November 2007 to July 2012. Its emission is detected with a statistical significance of 5.3 standard deviations. Parameterizing the source shape with a two-dimensional Gaussian function we estimate an extension \sigma=(0.40(+0.32,-0.22}) degree, consistent with the HESS measurement. The observed energy spectrum is dN/dE =(9.0-+1.6) x 10^{-13}(E/5 TeV)^{-2.32-+0.23} photons cm^{-2} s^{-1} TeV^{-1}, in the energy range 0.9-50 TeV. The integral \gamma-ray flux above 1 TeV is 1.3-+0.4 Crab units, which is 3.2-+1.0 times the flux derived by HESS. The differences in the flux determination between HESS and ARGO-YBJ, and possible counterparts at other wavelengths are discussed.Comment: 17 pages, 4 figures, have been accepted for publication in Ap

    Equilibrium configurations of two charged masses in General Relativity

    Get PDF
    An asymptotically flat static solution of Einstein-Maxwell equations which describes the field of two non-extreme Reissner - Nordstr\"om sources in equilibrium is presented. It is expressed in terms of physical parameters of the sources (their masses, charges and separating distance). Very simple analytical forms were found for the solution as well as for the equilibrium condition which guarantees the absence of any struts on the symmetry axis. This condition shows that the equilibrium is not possible for two black holes or for two naked singularities. However, in the case when one of the sources is a black hole and another one is a naked singularity, the equilibrium is possible at some distance separating the sources. It is interesting that for appropriately chosen parameters even a Schwarzschild black hole together with a naked singularity can be "suspended" freely in the superposition of their fields.Comment: 4 pages; accepted for publication in Phys. Rev.

    Current Ripple Analysis of New Double-Stator AC Drive Systems

    Get PDF
    This paper presents a current ripple analysis of new double-stator AC drive system. At first, a new double-stator AC drive system is proposed. The aim is to combine the benefits both the multilevel and multiphase system to provide the better performance to drive AC motor. The input and output current ripples of the proposed AC drive system are then analyzed. The current ripples of the proposed AC drive system are then compared to the ones of conventional double-stator AC drive system. Under the same DC input voltage, it is shown that the proposed results in less output current ripple. Under the same output voltage, the proposed AC drive system results in smaller input current and, therefore, fewer losses on the DC power supply. Experimental results are included to show the validity of the proposed concept

    Pharmacogenetics and Forensic Toxicology: A New Step towards a Multidisciplinary Approach

    Get PDF
    Pharmacogenetics analyzes the individual behavior of DNA genes after the administration of a drug. Pharmacogenetic research has been implemented in recent years thanks to the improvement in genome sequencing techniques and molecular genetics. In addition to medical purposes, pharmacogenetics can constitute an important tool for clarifying the interpretation of toxicological data in post-mortem examinations, sometimes crucial for determining the cause and modality of death. The purpose of this systematic literature review is not only to raise awareness among the forensic community concerning pharmacogenetics, but also to provide a workflow for forensic toxicologists to follow in cases of unknown causes of death related to drug use/abuse. The scientific community is called on to work hard in order to supply evidence in forensic practice, demonstrating that this investigation could become an essential tool both in civil and forensic contexts. The following keywords were used for the search engine: (pharmacogenetics) AND (forensic toxicology); (pharmacogenetics) AND (post-mortem); (pharmacogenetics) AND (forensic science); and (pharmacogenetics) AND (autopsy). A total of 125 articles were collected. Of these, 29 articles were included in this systematic review. A total of 75% of the included studies were original articles (n = 21) and 25% were case reports (n = 7). A total of 78% (n = 22) of the studies involved deceased people for whom a complete autopsy was performed, while 22% (n = 6) involved people in good health who were given a drug with a subsequent pharmacogenetic study. The most studied drugs were opioids (codeine, morphine, and methadone), followed by antidepressants (tricyclic antidepressants and venlafaxine). Furthermore, all studies highlighted the importance of a pharmacogenetics study in drug-related deaths, especially in cases of non-overdose of drugs of abuse. This study highlights the importance of forensic pharmacogenetics, a field of toxicology still not fully understood, which is of great help in cases of sudden death, deaths from overdose, deaths after the administration of a drug, and also in cases of complaint of medical malpractice

    New bidirectional step-up DC-DC converter derived from buck- boost DC-DC converter

    Get PDF
    This paper proposes a new bidirectional step-up DC-DC converter, namely modified buck-boost DC-DC converter. The proposed DC-DC converter was derived from the conventional buck-boost DC-DC converter. Output voltage expression of the proposed converter was derived by considering the voltage drops across inductors and switching devices. The results have shown that with the same parameter of input LC filter, proposed DC-DC converter has lower conduction losses. Moreover, the proposed DC-DC converter has lower rated voltage of filter capacitor than the conventional boost DC-DC converter which lead to cost efficiency. Finally, a scaled-down prototype of laboratory experiment was used to verify its theoretical analysis
    corecore