500 research outputs found
Spin tune mapping as a novel tool to probe the spin dynamics in storage rings
Precision experiments, such as the search for electric dipole moments of
charged particles using storage rings, demand for an understanding of the spin
dynamics with unprecedented accuracy. The ultimate aim is to measure the
electric dipole moments with a sensitivity up to 15 orders in magnitude better
than the magnetic dipole moment of the stored particles. This formidable task
requires an understanding of the background to the signal of the electric
dipole from rotations of the spins in the spurious magnetic fields of a storage
ring. One of the observables, especially sensitive to the imperfection magnetic
fields in the ring is the angular orientation of stable spin axis. Up to now,
the stable spin axis has never been determined experimentally, and in addition,
the JEDI collaboration for the first time succeeded to quantify the background
signals that stem from false rotations of the magnetic dipole moments in the
horizontal and longitudinal imperfection magnetic fields of the storage ring.
To this end, we developed a new method based on the spin tune response of a
machine to artificially applied longitudinal magnetic fields. This novel
technique, called \textit{spin tune mapping}, emerges as a very powerful tool
to probe the spin dynamics in storage rings. The technique was experimentally
tested in 2014 at the cooler synchrotron COSY, and for the first time, the
angular orientation of the stable spin axis at two different locations in the
ring has been determined to an unprecedented accuracy of better than
rad.Comment: 32 pages, 15 figures, 7 table
Phase Measurement for Driven Spin Oscillations in a Storage Ring
This paper reports the first simultaneous measurement of the horizontal and
vertical components of the polarization vector in a storage ring under the
influence of a radio frequency (rf) solenoid. The experiments were performed at
the Cooler Synchrotron COSY in J\"ulich using a vector polarized, bunched
deuteron beam. Using the new spin feedback system, we
set the initial phase difference between the solenoid field and the precession
of the polarization vector to a predefined value. The feedback system was then
switched off, allowing the phase difference to change over time, and the
solenoid was switched on to rotate the polarization vector. We observed an
oscillation of the vertical polarization component and the phase difference.
The oscillations can be described using an analytical model. The results of
this experiment also apply to other rf devices with horizontal magnetic fields,
such as Wien filters. The precise manipulation of particle spins in storage
rings is a prerequisite for measuring the electric dipole moment (EDM) of
charged particles
Measurement of the analyzing powers in pd elastic and pn quasi-elastic scattering at small angles
The analyzing powers in proton-deuteron elastic and proton-neutron
quasi-elastic scattering have been measured at small angles using a polarized
proton beam at the COSY storage ring incident on an unpolarized deuterium
target. The data were taken at 796MeV and five higher energies from 1600MeV to
2400MeV. The analyzing power in pd elastic scattering was studied by detecting
the low energy recoil deuteron in telescopes placed symmetrically in the COSY
plane to the left and right of the beam whereas for pn quasi-elastic scattering
a low energy proton was registered in one of the telescopes in coincidence with
a fast scattered proton measured in the ANKE magnetic spectrometer. Though the
experiment explores new domains, the results are consistent with the limited
published information.Comment: 10 pages with 8 figure
Phase locking the spin precession in a storage ring
This letter reports the successful use of feedback from a spin polarization
measurement to the revolution frequency of a 0.97 GeV/ bunched and polarized
deuteron beam in the Cooler Synchrotron (COSY) storage ring in order to control
both the precession rate ( kHz) and the phase of the horizontal
polarization component. Real time synchronization with a radio frequency (rf)
solenoid made possible the rotation of the polarization out of the horizontal
plane, yielding a demonstration of the feedback method to manipulate the
polarization. In particular, the rotation rate shows a sinusoidal function of
the horizontal polarization phase (relative to the rf solenoid), which was
controlled to within a one standard deviation range of rad. The
minimum possible adjustment was 3.7 mHz out of a revolution frequency of 753
kHz, which changes the precession rate by 26 mrad/s. Such a capability meets a
requirement for the use of storage rings to look for an intrinsic electric
dipole moment of charged particles
Toward polarized antiprotons: Machine development for spin-filtering experiments
The paper describes the commissioning of the experimental equipment and the
machine studies required for the first spin-filtering experiment with protons
at a beam kinetic energy of MeV in COSY. The implementation of a
low- insertion made it possible to achieve beam lifetimes of
s in the presence of a dense polarized hydrogen
storage-cell target of areal density . The developed techniques can be directly
applied to antiproton machines and allow for the determination of the
spin-dependent cross sections via spin filtering
Fungemia Associated with Left Ventricular Assist Device Support
Objective: Infections remain an important complication of left ventricular assist device (LVAD) support. While relatively uncommon, fungal infections present a serious concern given a high association with adverse events including death. We sought to further characterize the epidemiology of fungemias during LVAD support. Methods: Retrospective review of 292 patients receiving LVAD support from October 1996 to April 2009 at the University of Michigan Health System was done. Results: Seven cases of LVAD-associated fungemia were observed during the study period (0.1 infections/1000 days of device support). Five patients had infection with Candida species and two with Aspergillus species. The two patients with Aspergillus infection presented with disseminated disease, quickly dying of multiorgan failure, and sepsis. All five patients with Candida infections were successfully treated with systemic antifungal therapy along with transplantation in four of five patients. The fifth patient is receiving mechanical support as destination therapy. He remains on long-term suppression with high-dose fluconazole. Conclusions: Fungal infections appear to be a rare but serious complication of LVAD support. Future studies should aim to improve our understanding of risk factors for fungal infection during mechanical support, especially disseminated Aspergillus . Short-term perioperative antifungal prophylaxis with fluconazole appears to be an effective and reasonable approach to prevention. (J Card Surg 2009;24:763–765)Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/78694/1/j.1540-8191.2009.00919.x.pd
Recommended from our members
Vinyl Carbocations Generated under Basic Conditions and Their Intramolecular C–H Insertion Reactions
Here we report the surprising discovery that high-energy vinyl carbocations can be generated under strongly basic conditions, and that they engage in intramolecular sp³ C–H insertion reactions through the catalysis of weakly coordinating anion salts. This approach relies on the unconventional combination of lithium hexamethyldisilazide base and the commercially available catalyst, triphenylmethylium tetrakis(pentafluorophenyl)borate. These reagents form a catalytically active lithium species that enables the application of vinyl cation C–H insertion reactions to heteroatom-containing substrates
- …
