150 research outputs found
Validation of the Aura Microwave Limb Sounder HNOmeasurements
We assess the quality of the version 2.2 (v2.2) HNO3 measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System Aura satellite. The MLS HNO3 product has been greatly improved over that in the previous version (v1.5), with smoother profiles, much more realistic behavior at the lowest retrieval levels, and correction of a high bias caused by an error in one of the spectroscopy files used in v1.5 processing. The v2.2 HNO3 data are scientifically useful over the range 215 to 3.2 hPa, with single-profile precision of ∼0.7 ppbv throughout. Vertical resolution is 3–4 km in the upper troposphere and lower stratosphere, degrading to ∼5 km in the middle and upper stratosphere. The impact of various sources of systematic uncertainty has been quantified through a comprehensive set of retrieval simulations. In aggregate, systematic uncertainties are estimated to induce in the v2.2 HNO3 measurements biases that vary with altitude between ±0.5 and ±2 ppbv and multiplicative errors of ±5–15% throughout the stratosphere, rising to ∼±30% at 215 hPa. Consistent with this uncertainty analysis, comparisons with correlative data sets show that relative to HNO3 measurements from ground-based, balloon-borne, and satellite instruments operating in both the infrared and microwave regions of the spectrum, MLS v2.2 HNO3 mixing ratios are uniformly low by 10–30% throughout most of the stratosphere. Comparisons with in situ measurements made from the DC-8 and WB-57 aircraft in the upper troposphere and lowermost stratosphere indicate that the MLS HNO3 values are low in this region as well, but are useful for scientific studies (with appropriate averaging)
Validation of Aura Microwave Limb Sounder O-3 and CO observations in the upper troposphere and lower stratosphere
International audienceGlobal satellite observations of ozone and carbon monoxide from the Microwave Limb Sounder (MLS) on the EOS Aura spacecraft are discussed with emphasis on those observations in the 215–100 hPa region (the upper troposphere and lower stratosphere). The precision, resolution and accuracy of the data produced by the MLS “version 2.2” processing algorithms are discussed and quantified. O3 accuracy is estimated at ~40 ppbv +5% (~20 ppbv +20% at 215 hPa) while the CO accuracy is estimated at ~30 ppbv +30% for pressures of 147 hPa and less. Comparisons with expectations and other observations show good agreements for the O3 product, generally consistent with the systematic errors quoted above. In the case of CO, a persistent factor of ~2 high bias is seen at 215 hPa. However, the morphology is shown to be realistic, consistent with raw MLS radiance data, and useful for scientific study. The MLS CO data at higher altitudes are shown to be consistent with other observations
Validation of Aura Microwave Limb Sounder HCl measurements
The Earth Observing System (EOS) Microwave Limb Sounder (MLS) aboard the Aura satellite has provided daily global HCl profiles since August 2004. We provide a characterization of the resolution, random and systematic uncertainties, and known issues for the version 2.2 MLS HCl data. The MLS sampling allows for comparisons with many (similar to 1500 to more than 3000) closely matched profiles from the Halogen Occultation Experiment (HALOE) and Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS). These data sets provide HCl latitudinal distributions that are, overall, very similar to those from (coincident) MLS profiles, although there are some discrepancies in the upper stratosphere between the MLS and HALOE gradients. As found in previous work, MLS and ACE HCl profiles agree very well (within similar to 5%, on average), but the MLS HCl abundances are generally larger (by 10-20%) than HALOE HCl. The bias versus HALOE is unlikely to arise mostly from MLS, as a similar systematic bias (of order 15%) is not observed between average MLS and balloon-borne measurements of HCl, obtained over Fort Sumner, New Mexico, in 2004 and 2005. At the largest pressure (147 hPa) for MLS HCl, a high bias (similar to 0.2 ppbv) is apparent in analyses of low to midlatitude data versus in situ aircraft chemical ionization mass spectrometry (CIMS) HCl measurements from the Aura Validation Experiment (AVE) campaigns in 2004, 2005, and 2006; this bias is also observed in comparisons of MLS and aircraft HCl/O-3 correlations. Good agreement between MLS and CIMS HCl is obtained at 100 to 68 hPa. The recommended pressure range for MLS HCl is from 100 to 0.15 hPa.</p
Validation of the Aura Microwave Limb Sounder Temperature and Geopotential Height Measurements
This paper describes the retrievals algorithm used to determine temperature and height from radiance measurements by the Microwave Limb Sounder on EOS Aura. MLS is a "limbscanning" instrument, meaning that it views the atmosphere along paths that do not intersect the surface - it actually looks forwards from the Aura satellite. This means that the temperature retrievals are for a "profile" of the atmosphere somewhat ahead of the satellite. Because of the need to view a finite sample of the atmosphere, the sample spans a box about 1.5km deep and several tens of kilometers in width; the optical characteristics of the atmosphere mean that the sample is representative of a tube about 200-300km long in the direction of view. The retrievals use temperature analyses from NASA's Goddard Earth Observing System, Version 5 (GEOS-5) data assimilation system as a priori states. The temperature retrievals are somewhat deperrde~zt on these a priori states, especially in the lower stratosphere. An important part of the validation of any new dataset involves comparison with other, independent datasets. A large part of this study is concerned with such comparisons, using a number of independent space-based measurements obtained using different techniques, and with meteorological analyses. The MLS temperature data are shown to have biases that vary with height, but also depend on the validation dataset. MLS data are apparently biased slightly cold relative to correlative data in the upper troposphere and slightly warm in the middle stratosphere. A warm MLS bias in the upper stratosphere may be due to a cold bias in GEOS-5 temperatures
Validation of the Aura Microwave Limb Sounder Temperature and Geopotential Height Measurements
Global satellite observations of temperature and geopotential height (GPH) from the Microwave Limb Sounder (MLS) on the EOS Aura spacecraft are discussed. The precision, resolution, and accuracy of the data produced by the MLS version 2.2 processing algorithms are quantified, and recommendations for data screening are made. Temperature precision is 1 K or better from 316 hPa to 3.16 hPa, degrading to ∼3 K at 0.001 hPa. The vertical resolution is 3 km at 31.6 hPa, degrading to 6 km at 316 hPa and to ∼13 km at 0.001 hPa. Comparisons with analyses (Goddard Earth Observing System version 5.0.1 (GEOS-5), European Centre for Medium-range Weather Forecasts (ECMWF), Met Office (MetO)) and other observations (CHAllenging Minisatellite Payload (CHAMP), Atmospheric Infrared Sounder/Advanced Microwave Sounder Unit (AIRS/AMSU), Sounding of the Atmosphere using Broadband Radiometry (SABER), Halogen Occultation Experiment (HALOE), Atmospheric Chemistry Experiment (ACE), radiosondes) indicate that MLS temperature has persistent, pressure-dependent biases which are between −2.5 K and +1 K between 316 hPa and 10 hPa. The 100-hPa MLS v2.2 GPH surface has a bias of ∼150 m relative to the GEOS-5 values. These biases are compared to modeled systematic uncertainties. GPH biases relative to correlative measurements generally increase with height owing to an overall cold bias in MLS temperature relative to correlative temperature measurements in the upper stratosphere and mesosphere
Origin and insertion of the medial patellofemoral ligament: a systematic review of anatomy.
PURPOSE: The medial patellofemoral ligament (MPFL) is the major medial soft-tissue stabiliser of the patella, originating from the medial femoral condyle and inserting onto the medial patella. The exact position reported in the literature varies. Understanding the true anatomical origin and insertion of the MPFL is critical to successful reconstruction. The purpose of this systematic review was to determine these locations. METHODS: A systematic search of published (AMED, CINAHL, MEDLINE, EMBASE, PubMed and Cochrane Library) and unpublished literature databases was conducted from their inception to the 3 February 2016. All papers investigating the anatomy of the MPFL were eligible. Methodological quality was assessed using a modified CASP tool. A narrative analysis approach was adopted to synthesise the findings. RESULTS: After screening and review of 2045 papers, a total of 67 studies investigating the relevant anatomy were included. From this, the origin appears to be from an area rather than (as previously reported) a single point on the medial femoral condyle. The weighted average length was 56 mm with an 'hourglass' shape, fanning out at both ligament ends. CONCLUSION: The MPFL is an hourglass-shaped structure running from a triangular space between the adductor tubercle, medial femoral epicondyle and gastrocnemius tubercle and inserts onto the superomedial aspect of the patella. Awareness of anatomy is critical for assessment, anatomical repair and successful surgical patellar stabilisation. LEVEL OF EVIDENCE: Systematic review of anatomical dissections and imaging studies, Level IV
QUEST: A New Frontiers Uranus Orbiter Mission Concept Study
The ice giant planets, Uranus and Neptune, are fundamentally different from the gas giant and terrestrial planets. Though ice giants represent the most common size of exoplanet and possess characteristics that challenge our understanding of the way our solar system formed and evolved, they remain the only class of planetary object without a dedicated spacecraft mission. The inclusion of a Uranus orbiter as the third highest priority Flagship mission in the NASA Planetary Science Decadal Survey “Vision and Voyages for Planetary Science in the Decade 2013–2022” indicates a high level of support for exploration of the ice giants by the planetary science community. However, given the substantial costs associated with a flagship mission, it is critical to explore lower cost options if we intend to visit Uranus within an ideal launch window of 2029 - 2034 when a Jupiter gravity assist becomes available. In this paper, we describe the Quest to Uranus to Explore Solar System Theories (QUEST), a New Frontiers class Uranus orbiter mission concept study performed at the 30th Annual NASA/JPL Planetary Science Summer Seminar. The proposed QUEST platform is a spin-stabilized spacecraft designed to undergo highly elliptical, polar orbits around Uranus during a notional one-year primary science mission. The proposed major science goals of the mission are (1) to use Uranus as a natural laboratory to better understand the dynamos that drive magnetospheres in the solar system and beyond and (2) to identify the energy transport mechanisms in Uranus' magnetic, atmospheric, and interior environments in contrast with the other giant planets. With substantial mass, power, and cost margins, this mission concept demonstrates a compelling, feasible option for a New Frontiers Uranus orbiter mission
Ninety day mortality and its predictors after primary shoulder arthroplasty: an analysis of 4,019 patients from 1976-2008
Validation of the Aura Microwave Limb Sounder HNO3 Measurements
We assess the quality of the version 2.2 (v2.2) HNO3 measurements from the
Microwave Limb Sounder (MLS) on the Earth Observing System Aura satellite. The MLS
HNO3 product has been greatly improved over that in the previous version (v1.5), with
smoother profiles, much more realistic behavior at the lowest retrieval levels, and
correction of a high bias caused by an error in one of the spectroscopy files used in v1.5
processing. The v2.2 HNO3 data are scientifically useful over the range 215 to 3.2 hPa,
with single-profile precision of 0.7 ppbv throughout. Vertical resolution is 3–4 km in the
upper troposphere and lower stratosphere, degrading to 5 km in the middle and
upper stratosphere. The impact of various sources of systematic uncertainty has been
quantified through a comprehensive set of retrieval simulations. In aggregate, systematic
uncertainties are estimated to induce in the v2.2 HNO3 measurements biases that vary with
altitude between ±0.5 and ±2 ppbv and multiplicative errors of ±5–15% throughout the
stratosphere, rising to ±30% at 215 hPa. Consistent with this uncertainty analysis,
comparisons with correlative data sets show that relative to HNO3 measurements from
ground-based, balloon-borne, and satellite instruments operating in both the infrared
and microwave regions of the spectrum, MLS v2.2 HNO3 mixing ratios are uniformly low
by 10–30% throughout most of the stratosphere. Comparisons with in situ measurements
made from the DC-8 and WB-57 aircraft in the upper troposphere and lowermost
stratosphere indicate that the MLS HNO3 values are low in this region as well, but are
useful for scientific studies (with appropriate averaging).PublishedD24S401.7. Osservazioni di alta e media atmosferaJCR Journalreserve
C-Reactive Protein, Erythrocyte Sedimentation Rate and Orthopedic Implant Infection
BACKGROUND: C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) have been shown to be useful for diagnosis of prosthetic hip and knee infection. Little information is available on CRP and ESR in patients undergoing revision or resection of shoulder arthroplasties or spine implants. METHODS/RESULTS: We analyzed preoperative CRP and ESR in 636 subjects who underwent knee (n=297), hip (n=221) or shoulder (n=64) arthroplasty, or spine implant (n=54) removal. A standardized definition of orthopedic implant-associated infection was applied. Receiver operating curve analysis was used to determine ideal cutoff values for differentiating infected from non-infected cases. ESR was significantly different in subjects with aseptic failure infection of knee (median 11 and 53.5 mm/h, respectively, p=<0.0001) and hip (median 11 and 30 mm/h, respectively, p=<0.0001) arthroplasties and spine implants (median 10 and 48.5 mm/h, respectively, p=0.0033), but not shoulder arthroplasties (median 10 and 9 mm/h, respectively, p=0.9883). Optimized ESR cutoffs for knee, hip and shoulder arthroplasties and spine implants were 19, 13, 26, and 45 mm/h, respectively. Using these cutoffs, sensitivity and specificity to detect infection were 89 and 74% for knee, 82 and 60% for hip, and 32 and 93% for shoulder arthroplasties, and 57 and 90% for spine implants. CRP was significantly different in subjects with aseptic failure and infection of knee (median 4 and 51 mg/l, respectively, p<0.0001), hip (median 3 and 18 mg/l, respectively, p<0.0001), and shoulder (median 3 and 10 mg/l, respectively, p=0.01) arthroplasties, and spine implants (median 3 and 20 mg/l, respectively, p=0.0011). Optimized CRP cutoffs for knee, hip, and shoulder arthroplasties, and spine implants were 14.5, 10.3, 7, and 4.6 mg/l, respectively. Using these cutoffs, sensitivity and specificity to detect infection were 79 and 88% for knee, 74 and 79% for hip, and 63 and 73% for shoulder arthroplasties, and 79 and 68% for spine implants. CONCLUSION: CRP and ESR have poor sensitivity for the diagnosis of shoulder implant infection. A CRP of 4.6 mg/l had a sensitivity of 79 and a specificity of 68% to detect infection of spine implants
- …
