2,219 research outputs found
Starspots and spin-orbit alignment for Kepler cool host stars
The angle between the spin axis of the host star and the orbit of its planets
(i.e., the stellar obliquity) is precious information about the formation and
evolution of exoplanetary systems. Measurements of the Rossiter-McLaughlin
effect revealed that many stars that host a hot-Jupiter have high obliquities,
suggesting that hot-Jupiter formation involves excitation of orbital
inclinations. In this contribution we show how the passage of the planet over
starspots can be used to measure the obliquity of exoplanetary systems. This
technique is used to obtain - for the first time - the obliquity of a system
with several planets that lie in a disk, Kepler-30, with the result that the
star has an obliquity smaller than 10 degrees. The implications for the
formation of exoplanetary systems, in particular the hot-Jupiter population,
are also discussed.Comment: To appear in special edition of AN, proceedings of the Cool Stars 17
conference, Barcelona June 201
A number or a person?: perspectives on credit scoring and fair mortgage lending: article four in a five-part series
This fourth article in a five-part series on credit scoring showcases three different perspectives. Up for debate is how lenders can ensure fair treatment to all mortgage applicants and how consumers can be educated about the effect their credit score has on loan pricing.Mortgage loans
A search for rapidly pulsating hot subdwarf stars in the GALEX survey
NASA's Galaxy Evolution Explorer (GALEX) provided near- and far-UV
observations for approximately 77 percent of the sky over a ten-year period;
however, the data reduction pipeline initially only released single NUV and FUV
images to the community. The recently released Python module gPhoton changes
this, allowing calibrated time-series aperture photometry to be extracted
easily from the raw GALEX data set. Here we use gPhoton to generate light
curves for all hot subdwarf B (sdB) stars that were observed by GALEX, with the
intention of identifying short-period, p-mode pulsations. We find that the
spacecraft's short visit durations, uneven gaps between visits, and dither
pattern make the detection of hot subdwarf pulsations difficult. Nonetheless,
we detect UV variations in four previously known pulsating targets and report
their UV pulsation amplitudes and frequencies. Additionally, we find that
several other sdB targets not previously known to vary show promising signals
in their periodograms. Using optical follow-up photometry with the Skynet
Robotic Telescope Network, we confirm p-mode pulsations in one of these
targets, LAMOST J082517.99+113106.3, and report it as the most recent addition
to the sdBVr class of variable stars.Comment: 11 Pages, 8 Figures, Accepted for publication in the Astrophysical
Journa
Weight-Bearing Asymmetry in Individuals Post-Hip Fracture During the Sit to Stand Task
Background: Individuals post hip fracture decrease force on the involved limb during sit to stand tasks, creating an asymmetry in vertical ground reaction force. Joint specific differences that underlie asymmetry of the vertical ground reaction force are unknown. The purpose of this study was to compare differences in vertical ground reaction force variables and joint kinetics at the hip and knee in participants post-hip fracture, who were recently discharged from home care physical therapy to controls.
Methods: Forty-four community-dwelling older adults, 29 who had a hip fracture and 15 elderly control participant’s completed the sit to stand task on an instrumented chair with 3 force plates. T-tests were used to compare clinical tests (Berg Balance Scale, activity balance confidence and gait speed, isokinetic knee strength) and vertical ground reaction force variables. Two-way analyses of variance compared vertical ground reaction force variables and kinetics at the hip and knee between hip fracture and elderly control groups. Pearson correlation coefficients were used to determine correlations between clinical and vertical ground reaction force variables.
Findings: Vertical ground reaction force variables were significantly lower on the involved side for the hip fracture group compared to the uninvolved side and controls. Lower involved side hip and knee moments and power contributed to lower involved side vertical ground reaction force. Vertical ground reaction force variables and strength had moderate to high correlations with clinical measures.
Interpretation: Uninvolved side knee movements and powers were the largest contributors to asymmetrical vertical ground reaction force in participants post-hip fracture. The association of vertical ground reaction force variables and clinical measures of function suggesting reducing vertical ground reaction force asymmetry may contribute to higher levels of function post-hip fracture. Functional and strength training should target the involved knee to reduce vertical ground reaction force asymmetry. Background Individuals post hip fracture decrease force on the involved limb during sit to stand tasks, creating an asymmetry in vertical ground reaction force. Joint specific differences that underlie asymmetry of the vertical ground reaction force are unknown. The purpose of this study was to compare differences in vertical ground reaction force variables and joint kinetics at the hip and knee in participants post-hip fracture, who were recently discharged from homecare physical therapy to controls. Methods Forty-four community-dwelling older adults, 29 who had a hip fracture and 15 elderly control participant’s completed the sit to stand task on an instrumented chair with 3 force plates. T-tests were used to compare clinical tests (Berg Balance Scale, activity balance confidence and gait speed, isokinetic knee strength) and vertical ground reaction force variables. Two-way analyses of variance compared vertical ground reaction force variables and kinetics at the hip and knee between hip fracture and elderly control groups. Pearson correlation coefficients were used to determine correlations between clinical and vertical ground reaction force variables. Findings Vertical ground reaction force variables were significantly lower on the involved side for the hip fracture group compared to the uninvolved side and controls. Lower involved side hip and knee moments and power contributed to lower involved side vertical ground reaction force. Vertical ground reaction force variables and strength had moderate to high correlations with clinical measures. Interpretation Uninvolved side knee moments and powers were the largest contributors to asymmetrical vertical ground reaction force in participants post-hip fracture. The association of vertical ground reaction force variables and clinical measures of function suggesting reducing vertical ground reaction force asymmetry may contribute to higher levels of function post-hip fracture. Functional and strength training should target the involved knee to reduce vertical ground reaction force asymmetry
Recommended from our members
Silicon Carbide Growth Using Laser Chemical Vapor Deposition
Silicon Carbide (SiC) has been grown from methyltrichlorosilane (MTS) and
hydrogen using the Georgia Tech Laser Chemical Vapor Deposition (LCVD) system. A
morphology study of LCVD-SiC fibers and lines was completed. Graphite and single
crystal silicon were used as the substrates. In order to provide guidance to future growth
of SiC, thermodynamic calculations for the C-H-Si-Cl system were performed using the
SOLGASMIX-PV program.Mechanical Engineerin
Fluorescence-Activated Cell Sorting of Live Versus Dead Bacterial Cells and Spores
This innovation is a coupled fluorescence-activated cell sorting (FACS) and fluorescent staining technology for purifying (removing cells from sampling matrices), separating (based on size, density, morphology, and live versus dead), and concentrating cells (spores, prokaryotic, eukaryotic) from an environmental sample
- …
