168 research outputs found

    On the Response of an OST to a Point-like Heat Source

    Full text link
    A new technique of superconducting cavity diagnostics has been introduced by D. Hartrill at Cornell University, Ithaca, USA. Oscillating Superleak Transducers (OST) detect the heat transferred from a cavity's quench point via "Second Sound" through the superfluid He bath, needed to cool the superconducting cavity. The observed response of an OST is a complex, but reproducible pattern of oscillations. A small helium evaporation cryostat was built which allows the investigation of the response of an OST in greater detail. The distance between a point-like electrical heater and the OST can be varied. The OST can be mounted either parallel or perpendicular to the plate, housing the heat source. If the artificial quench-point releases an amount of energy compatible to a real quench spot on a cavity's surface, the OST signal starts with a negative pulse, which is usually strong enough to allow automatic detection. Furthermore, the reflection of the Second Sound on the wall is observed. A reflection coefficient R = 0.39 +- 0.05 of the glass wall is measured. This excludes a strong influence of multiple reflections in the complex OST response. Fourier analyses show three main frequencies, found in all OST spectra. They can be interpreted as modes of an oscillating circular membrane.Comment: 10 pages, 16 figure

    Gefäßmedizin heute: Die Berner Sicht

    Get PDF
    Zusammenfassung: Die moderne Behandlung von Gefäßpatienten stellt eine reizvolle und anspruchsvolle Aufgabe dar, welche aufgrund der Komplexität und der Breite des Spektrums heute in interdisziplinären Gefäßzentren durchgeführt werden sollte. Die enge Zusammenarbeit zwischen Gefäßchirurgen und Angiologen hat an der Universität Bern eine lange Tradition. Der vorliegende Artikel legt die grundlegende Philosophie unserer gefäßchirurgisch-angiologischen Freundschaft und Zusammenarbeit dar und schildert deren Umsetzung im klinischen Allta

    Use of biomarkers or echocardiography in pulmonary embolism: the Swiss Venous Thromboembolism Registry

    Get PDF
    Background: Cardiac biomarkers and echocardiography for assessing right ventricular function are recommended to risk stratify patients with acute non-massive pulmonary embolism (PE), but it remains unclear if these tests are performed systematically in daily practice. Design and methods: Overall, 587 patients with acute non-massive PE from 18 hospitals were enrolled in the Swiss Venous Thromboembolism Registry (SWIVTER): 178 (30%) neither had a biomarker test nor an echocardiographic evaluation, 196 (34%) had a biomarker test only, 47 (8%) had an echocardiogram only and 166 (28%) had both tests. Results: Among the 409 (70%) patients with biomarkers or echocardiography, 210 (51%) had at least one positive test and 67 (16%) had positive biomarkers and right ventricular dysfunction. The ICU admission rates were 5.1% without vs. 5.6% with testing (P = 0.78), and thrombolysis or embolectomy were performed in 2.8% vs. 4.9%, respectively (P = 0.25). In multivariate analysis, syncope [odds ratio (OR): 3.49, 95% confidence interval (CI): 1.20-10.15; P = 0.022], tachycardia (OR: 2.31, 95% CI: 1.37-3.91; P = 0.002) and increasing age (OR: 1.02; 95% CI: 1.01-1.04; P < 0.001) were associated with testing of cardiac risk; outpatient status at the time of PE diagnosis (OR: 2.24, 95% CI: 1.49-3.36; P < 0.001), cancer (OR: 1.81, 95% CI: 1.17-2.79; P = 0.008) and provoked PE (OR: 1.58, 95% CI: 1.05-2.40; P = 0.029) were associated with its absence. Conclusions: Although elderly patients and those with clinically severe PE were more likely to receive a biomarker test or an echocardiogram, these tools were used in only two-thirds of the patients with acute non-massive PE and rarely in combinatio

    Controlling chaos in a Lorenz-like system using feedback

    Get PDF
    We demonstrate that the dynamics of an autonomous chaotic laser can be controlled to a periodic or steady state under self-synchronization. In general, past the chaos threshold the dependence of the laser output on feedback applied to the pump is submerged in the Lorenz-like chaotic pulsation. However there exist specific feedback delays that stabilize the chaos to periodic behavior or even steady state. The range of control depends critically on the feedback delay time and amplitude. Our experimental results are compared with the complex Lorenz equations which show good agreement

    Transforming chaos to periodic oscillations

    Get PDF
    We demonstrate that the dynamics of an autonomous chaotic class C laser can be controlled to a periodic state via external modulation of the pump. In the absence of modulation, above the chaos threshold, the laser exhibits Lorenz-like chaotic pulsations. The average amplitude and frequency of these pulsations depend on the pump power. We find that there exist parameter windows where modulation of the pump power extinguishes the chaos in favor of simpler periodic behavior. Moreover we find a number of locking ratios between the pump and laser output follow the Farey sequence

    Antimicrobial Peptides and Skin: A Paradigm of Translational Medicine

    Get PDF
    Antimicrobial peptides (AMPs) are small, cationic, amphiphilic peptides with broad-spectrum microbicidal activity against both bacteria and fungi. In mammals, AMPs form the first line of host defense against infections and generally play an important role as effector agents of the innate immune system. The AMP era was born more than 6 decades ago when the first cationic cyclic peptide antibiotics, namely polymyxins and tyrothricin, found their way into clinical use. Due to the good clinical experience in the treatment of, for example, infections of mucus membranes as well as the subsequent understanding of mode of action, AMPs are now considered for treatment of inflammatory skin diseases and for improving healing of infected wounds. Based on the preclinical findings, including pathobiochemistry and molecular medicine, targeted therapy strategies are developed and first results indicate that AMPs influence processes of diseased skin. Importantly, in contrast to other antibiotics, AMPs do not seem to propagate the development of antibiotic-resistant micro-organisms. Therefore, AMPs should be tested in clinical trials for their efficacy and tolerability in inflammatory skin diseases and chronic wounds. Apart from possible fields of application, these peptides appear suited as an example of the paradigm of translational medicine for skin diseases which is today seen as a `two-way road' - from bench to bedside and backwards from bedside to bench. Copyright (c) 2012 S. Karger AG, Base

    Field induced phases in UPt2Si2

    Full text link
    The tetragonal compound UPt2Si2 has been characterised as a moderately mass enhanced system with an antiferromagnetic ground state below T_N = 32 K. Here, we present an extensive study of the behavior in high magnetic fields. We have performed pulsed field magnetization and static field resistivity measurements on single crystalline samples UPt2Si2. Along the crystallographic a axis, at low temperatures, we find a metamagnetic-like transition in fields of the order 40 T, possibly indicating a first order transition. Along the crystallographic c axis, in magnetic fields of B>= ~24 T, we find distinct anomalies in both properties. From our analysis of the data we can distinguish new high field phases above the AFM ground state. We discuss the emergence of these new phases in the context of Fermi surface effects and the possible occurrence of a Lifshitz or electronic topological transition, this in contrast to previous modellings of UPt2Si2 based on crystal electric field effects.Comment: 10 pages, submitted to PR

    Electron Counting Capacitance Standard with an improved five-junction R-pump

    Full text link
    The Electron Counting Capacitance Standard currently pursued at PTB aims to close the Quantum Metrological Triangle with a final precision of a few parts in 10^7. This paper reports the considerable progress recently achieved with a new generation of single-electron tunnelling devices. A five-junction R-pump was operated with a relative charge transfer error of five electrons in 10^7, and was used to successfully perform single-electron charging of a cryogenic capacitor. The preliminary result for the single-electron charge quantum has an uncertainty of less than two parts in 10^6 and is consistent with the value of the elementary charge.Comment: 16 pages, 9 figures, 1 tabl

    Associations of occupational standing with musculoskeletal symptoms: A systematic review with meta-analysis

    Get PDF
    Objective Given the high exposure to occupational standing in specific occupations, and recent initiatives to encourage intermittent standing among white-collar workers, a better understanding of the potential health consequences of occupational standing is required. We aimed to review and quantify the epidemiological evidence on associations of occupational standing with musculoskeletal symptoms. Design A systematic review was performed. Data from included articles were extracted and described, and meta-analyses conducted when data were sufficiently homogeneous. Data sources Electronic databases were systematically searched. Eligibility criteria Peer-reviewed articles on occupational standing and musculoskeletal symptoms from epidemiological studies were identified. Results Of the 11 750 articles screened, 50 articles reporting 49 studies were included (45 cross-sectional and 5 longitudinal; n=88 158 participants) describing the associations of occupational standing with musculoskeletal symptoms, including low-back (39 articles), lower extremity (14 articles) and upper extremity (18 articles) symptoms. In the meta-analysis, 'substantial' (&gt;4 hours/workday) occupational standing was associated with the occurrence of low-back symptoms (pooled OR (95% CI) 1.31 (1.10 to 1.56)). Evidence on lower and upper extremity symptoms was too heterogeneous for meta-analyses. The majority of included studies reported statistically significant detrimental associations of occupational standing with lower extremity, but not with upper extremity symptoms. Conclusions The evidence suggests that substantial occupational standing is associated with the occurrence of low-back and (inconclusively) lower extremity symptoms, but there may not be such an association with upper extremity symptoms. However, these conclusions are tentative as only limited evidence was found from high-quality, longitudinal studies with fully adjusted models using objective measures of standing

    Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study

    Get PDF
    Background Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Methods Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). Results A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CVW. Conclusions Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula
    corecore