118 research outputs found
Technical Note: Field experiences using UV/VIS sensors for high-resolution monitoring of nitrate in groundwater
peer-reviewedTwo different in situ spectrophotometers are compared that were used in the field to determine nitrate-nitrogen (NO3-N) concentrations at two distinct spring discharge sites. One sensor was a double wavelength spectrophotometer (DWS) and the other a multiple wavelength spectrophotometer (MWS). The objective of the study was to review the hardware options, determine ease of calibration, accuracy, influence of additional substances and to assess positive and negative aspects of the two sensors as well as troubleshooting and trade-offs. Both sensors are sufficient to monitor highly time-resolved NO3-N concentrations in emergent groundwater. However, the chosen path length of the sensors had a significant influence on the sensitivity and the range of detectable NO3-N. The accuracy of the calculated NO3-N concentrations of the sensors can be affected if the content of additional substances such as turbidity, organic matter, nitrite or hydrogen carbonate significantly varies after the sensors have been calibrated to a particular water matrix. The MWS offers more possibilities for calibration and error detection but requires more expertise compared with the DWS.The authors would like to acknowledge
the Teagasc Walsh Fellowship scheme for funding the study in Ireland, and the German federal Ministry of Education and Research (BMBF) for sponsoring the SMART-project (grant
no. 02WM1079-1086, 02WM1211-1212) for the study in Jordan.Teagasc Walsh Fellowship Programm
On-Chip Contactless Four-Electrode Conductivity Detection for Capillary Electrophoresis Devices
In this contribution, a capillary electrophoresis microdevice with an integrated on-chip contactless fourelectrode conductivity detector is presented. A 6-cm-long, 70-µm-wide, and 20-µm-deep channel was etched in a glass substrate that was bonded to a second glass substrate in order to form a sealed channel. Four contactless electrodes (metal electrodes covered by 30-nm silicon carbide) were deposited and patterned on the second glass substrate for on-chip conductivity detection. Contactless conductivity detection was performed in either a two-or a four-electrode configuration. Experimental results confirmed the improved characteristics of the fourelectrode configuration over the classical two-electrode detection setup. The four-electrode configuration allows for sensitive detection for varying carrier-electrolyte background conductivity without the need for adjustment of the measurement frequency. Reproducible electrophoretic separations of three inorganic cations (K + , Na + , Li + ) and six organic acids are presented. Detection as low as 5 µM for potassium was demonstrated. In the development and optimization of miniaturized analytical systems, a delicate combination of science and technology originating from microelectronic device fabrication, electrical engineering, and analytical chemistry is essential. In this multidisciplinary field, microtechnology experts combine the demands from analytical chemistry and electronic instrumentation in the design and fabrication of novel analytical devices. 1,2 Chemical analysis systems, such as high-performance liquid chromatography (HPLC) or capillary electrophoresis (CE), always consist of the combination of a separation and a detection system. For separation, CE or CE-based separation techniques are highly suitable for implementation on the microchip format. Electrokinetic control of fluid transport eliminates the need for external components such as pumps and valves. The separation efficiency is relatively independent of the separation path length and is, therefore, more compatible with miniaturization than, for instance, chromatographic techniques. As far as detection is concerned, laser-induced fluorescence (LIF) is, at present, the most widely used detection technique in miniaturized analysis systems because of its high sensitivity. The drawbacks of LIF are its limited compatibility with miniaturization and on-chip integration and the requirement for labeling of most (bio) chemically relevant compounds. External devices such as the relatively large laser and the photodetector system strongly prohibit further miniaturization. The development of alternative detection methods compatible with miniaturization and full onchip integration is highly desirable. Since electrode deposition is a well-established process in microfabrication, the implementation of detection techniques utilizing integrated electrodes has become an attractive approach. Successful coupling of conventional CE with potentiometry, 3 amperometry, 4,5 and conductometry 6-10 has been reported in the literature. In addition, both amperometric and potentiometric detection were also implemented in chip-based CE systems. [11][12][13] The primary advantage of amperometric and potentiometric detection over conductivity detection is the high selectivity induced by the electrochemical reactions that take place at the electrode surface. Only electrochemically active compounds * Corresponding author: (tel) +31 (0) 15 278 6518; (fax) +31 (0) 15 278 5755
Impact of primary kidney disease on the effects of empagliflozin in patients with chronic kidney disease: secondary analyses of the EMPA-KIDNEY trial
Background: The EMPA KIDNEY trial showed that empagliflozin reduced the risk of the primary composite outcome of kidney disease progression or cardiovascular death in patients with chronic kidney disease mainly through slowing progression. We aimed to assess how effects of empagliflozin might differ by primary kidney disease across its broad population. Methods: EMPA-KIDNEY, a randomised, controlled, phase 3 trial, was conducted at 241 centres in eight countries (Canada, China, Germany, Italy, Japan, Malaysia, the UK, and the USA). Patients were eligible if their estimated glomerular filtration rate (eGFR) was 20 to less than 45 mL/min per 1·73 m2, or 45 to less than 90 mL/min per 1·73 m2 with a urinary albumin-to-creatinine ratio (uACR) of 200 mg/g or higher at screening. They were randomly assigned (1:1) to 10 mg oral empagliflozin once daily or matching placebo. Effects on kidney disease progression (defined as a sustained ≥40% eGFR decline from randomisation, end-stage kidney disease, a sustained eGFR below 10 mL/min per 1·73 m2, or death from kidney failure) were assessed using prespecified Cox models, and eGFR slope analyses used shared parameter models. Subgroup comparisons were performed by including relevant interaction terms in models. EMPA-KIDNEY is registered with ClinicalTrials.gov, NCT03594110. Findings: Between May 15, 2019, and April 16, 2021, 6609 participants were randomly assigned and followed up for a median of 2·0 years (IQR 1·5–2·4). Prespecified subgroupings by primary kidney disease included 2057 (31·1%) participants with diabetic kidney disease, 1669 (25·3%) with glomerular disease, 1445 (21·9%) with hypertensive or renovascular disease, and 1438 (21·8%) with other or unknown causes. Kidney disease progression occurred in 384 (11·6%) of 3304 patients in the empagliflozin group and 504 (15·2%) of 3305 patients in the placebo group (hazard ratio 0·71 [95% CI 0·62–0·81]), with no evidence that the relative effect size varied significantly by primary kidney disease (pheterogeneity=0·62). The between-group difference in chronic eGFR slopes (ie, from 2 months to final follow-up) was 1·37 mL/min per 1·73 m2 per year (95% CI 1·16–1·59), representing a 50% (42–58) reduction in the rate of chronic eGFR decline. This relative effect of empagliflozin on chronic eGFR slope was similar in analyses by different primary kidney diseases, including in explorations by type of glomerular disease and diabetes (p values for heterogeneity all >0·1). Interpretation: In a broad range of patients with chronic kidney disease at risk of progression, including a wide range of non-diabetic causes of chronic kidney disease, empagliflozin reduced risk of kidney disease progression. Relative effect sizes were broadly similar irrespective of the cause of primary kidney disease, suggesting that SGLT2 inhibitors should be part of a standard of care to minimise risk of kidney failure in chronic kidney disease. Funding: Boehringer Ingelheim, Eli Lilly, and UK Medical Research Council
Calcite formation on steamed concrete surfaces and its potential for sealing cracks
Under accidental conditions, concrete containments of nuclear power plants often remain as final barrier to the environment. To evaluate the contribution of self-healing processes of cracked concrete containments, small scale experiments were conducted for given accident scenarios to examine the mineralogical processes on cement crack surfaces in contact with hot steam-air mixes. The surface analyses with ESEM, µ-RFA and microscope showed a calcite formation, where layer thicknesses increased along the exposure times until reaching a stable level. The potential for crack healing was principally demonstrated through flow measurements, where the outflowing mass decreased during the experiments along with increasing calcite formation
Investigating the self-healing potential of cracked concrete under variable loads in real and laboratory scale
Cracks in concrete containment - comparing the self-healing potential under variable air and steam loads between real scale and laboratory scale
Water quality monitoring for groundwater protection in urban karst aquifers in a semi-arid climate
Cooperativity between antibiotics and antiseptics: testing the bactericidal effect
Objective: Treatment with antibiotics together with local application of antiseptics is common in wound care. We investigated the effectiveness of an antiseptic in two variations: octenidine (Oct) and octenidine+ (Oct+ with isotonic glucose addition). Method: Using the agar diffusion test with cultures of pathogenic Staphylococcus aureus and the non-pathogenic Bordetella petrii, we compared the effectiveness of octenidine to the classical antiseptics beta-isodona (povidone-iodine; PI), chlorhexidine (Chl) and taurolin (Tau) alone, and in combination with various common antibiotics to uncover cooperativity between antiseptics and antibiotics. Results: We detected strong interactions between antibiotics and antiseptics, that either enhanced or reduced the bactericidal efficiency. Effectiveness was dependent on the type of organism tested. Oct applied together with ineffective antibiotics frequently led to effective growth inhibition of Bordetella petrii. With Staphylococcus aureus we did not find such an effect. To this end, we reason that positively charged Oct may associate with antibiotic compounds via electrostatic interactions and guide it more efficiently to the bacterial cell wall. Interaction with antibiotics sometimes led to sequestration and reduced availability of some antiseptic/antibiotic combinations, but never with Oct. Conclusion: These data provide new arguments for decision planning concerning the choice of agent in the treatment of wound infections. </jats:sec
- …
