9,542 research outputs found
Natural statistics for spectral samples
Spectral sampling is associated with the group of unitary transformations
acting on matrices in much the same way that simple random sampling is
associated with the symmetric group acting on vectors. This parallel extends to
symmetric functions, k-statistics and polykays. We construct spectral
k-statistics as unbiased estimators of cumulants of trace powers of a suitable
random matrix. Moreover we define normalized spectral polykays in such a way
that when the sampling is from an infinite population they return products of
free cumulants.Comment: Published in at http://dx.doi.org/10.1214/13-AOS1107 the Annals of
Statistics (http://www.imstat.org/aos/) by the Institute of Mathematical
Statistics (http://www.imstat.org
A review on the prevention of inflammatory periimplant diseases
Background: An impressive number of dental implants are inserted worldwide. Evolution in dental implants and simplification of surgical techniques allowed a significant increase in the number of dentists involved in implant surgery. Most of them are general dentists, are not always sufficiently formed and experienced, frequently use low-quality implants, do not adopt the proper patient selective criteria, do not adequately monitor and maintain the inserted implants, and do not report their own statistics to the dental community. Consequently, the incidence of inflammatory periimplant diseases (IPDs) has progressively increased to values significantly higher than those previously indicated by the scientific literature. Materials and Methods: Two main literature searches were undertaken in October 2018 in the PubMed Website database. Only articles written in English and published from 2008 onward were considered; 'Clinical Trial,' 'Meta analysis,' 'Observational study,' 'Review,' and 'Validation study' were selected as article type filters. The following keywords were used in the searches: 'Peri implantitis prevention' and 'Dental implant failure prevention.'Results: Preventive measures are analyzed according to the different factors that can favor the occurrence of an infection. The factors are divided into (i) implant dependent, (ii) patient dependent, and (iii) surgeon dependent. Conclusions: Scientific and clinical data confirm that when materials are selected with care, patients are carefully evaluated for factors of risk and attitude to adhere to the necessary maintenance program, and operative protocols and maintenance programs are respected dental implants can be attractive and effective tools for oral rehabilitation. Nevertheless, dentists and patients should have greater awareness that in many cases the decision to utilize dental implants cannot be taken lightly
Finite Temperature Effective Potential for Gauge Models in de Sitter Space
The one-loop effective potential for gauge models in static de Sitter space
at finite temperatures is computed by means of the --function method. We
found a simple relation which links the effective potentials of gauge and
scalar fields at all temperatures.
In the de Sitter invariant and zero-temperature states the potential for the
scalar electrodynamics is explicitly obtained, and its properties in these two
vacua are compared. In this theory the two states are shown to behave similarly
in the regimes of very large and very small radii a of the background space.
For the gauge symmetry broken in the flat limit () there is a
critical value of a for which the symmetry is restored in both quantum states.
Moreover, the phase transitions which occur at large or at small a are of the
first or of the second order, respectively, regardless the vacuum considered.
The analytical and numerical analysis of the critical parameters of the above
theory is performed. We also established a class of models for which the kind
of phase transition occurring depends on the choice of the vacuum.Comment: 23 pages, LaTeX, 5 figure.ep
Competition between Visual Events Modulates the Influence of Salience during Free-Viewing of Naturalistic Videos
In daily life the brain is exposed to a large amount of external signals that compete for processing resources. The attentional system can select relevant information based on many possible combinations of goal-directed and stimulus-driven control signals. Here, we investigate the behavioral and physiological effects of competition between distinctive visual events during free-viewing of naturalistic videos. Nineteen healthy subjects underwent functional magnetic resonance imaging (fMRI) while viewing short video-clips of everyday life situations, without any explicit goal-directed task. Each video contained either a single semantically-relevant event on the left or right side (Lat-trials), or multiple distinctive events in both hemifields (Multi-trials). For each video, we computed a salience index to quantify the lateralization bias due to stimulus-driven signals, and a gaze index (based on eye-tracking data) to quantify the efficacy of the stimuli in capturing attention to either side. Behaviorally, our results showed that stimulus-driven salience influenced spatial orienting only in presence of multiple competing events (Multi-trials). fMRI results showed that the processing of competing events engaged the ventral attention network, including the right temporoparietal junction (R TPJ) and the right inferior frontal cortex. Salience was found to modulate activity in the visual cortex, but only in the presence of competing events; while the orienting efficacy of Multi-trials affected activity in both the visual cortex and posterior parietal cortex (PPC). We conclude that in presence of multiple competing events, the ventral attention system detects semantically-relevant events, while regions of the dorsal system make use of saliency signals to select relevant locations and guide spatial orienting
Role of the flat-designed surface in improving the cyclic fatigue resistance of endodontic NiTi rotary instruments
The aim of this study was to investigate the role of the flat-designed surface in improving the resistance to cyclic fatigue by comparing heat-treated F-One (Fanta Dental, Shanghai, China) nickel-titanium (NiTi) rotary instruments and similar prototypes, differing only by the absence of the flat side. The null hypothesis was that there were no differences between the two tested instruments in terms of cyclic fatigue lifespan. A total of 40 new NiTi instruments (20 F-One and 20 prototypes) were tested in the present study. The instruments were rotated with the same speed (500 rpm) and torque (2 N) using an endodontic motor (Elements Motor, Kerr, Orange, CA, USA) in the same stainless steel, artificial canal (90° angle of curvature and 5 mm radius). A Wilcoxon-Mann-Whitney test was performed to assess the differences in terms of time to fracture and the length of the fractured segment between the flat- and non-flat-sided instruments. Significance was set at p = 0.05. The differences in terms of time to fracture between non-flat and flat were statistically significant (p < 0.001). In addition, the differences in terms of fractured segment length were statistically significant (p = 0.034). The results of this study highlight the importance of flat-sided design in increasing the cyclic fatigue lifespan of NiTi rotary instruments
In vivo evaluation of operative torque generated by two Nickel-Titanium rotary instruments during root canal preparation
Objectives This in vivo study evaluated the operative torque and preparation time of ProTaper NEXT (Dentsply Maillefer; Ballaigues, Switzerland) and EdgeFile X7 (EdgeEndo; Albuquerque, New Mexico, United States) rotary systems during root canal preparation of maxillary premolars. Materials and Methods Ten double-rooted maxillary premolars with independent canals were selected. Each canal in each tooth was prepared with one of the rotary systems (n = 10), ProTaper NEXT or EdgeFile X7. The instruments were rotated at 300 rpm with maximum torque set at 2 N.cm using an electric motor (KaVo; Biberach, Germany) that automatically recorded torque values at every 1/10th of a second (ds). Statistical Analysis Operative torque (N.cm) and preparation time (s) of the first shaping instrument (size 17/.04) of both rotary systems were recorded and statistically compared using the Mann-Whiney U test with a significance level set at 5%. Results No instrument exhibited flute deformation or underwent intracanal failure. No differences were found between the instruments regarding the maximum (peak) torque values (p > 0.05). EdgeFile X7 17/.04 required significantly less preparation time (3.75 seconds interquartile range [IQR]: 3.2-9.0) than ProTaper NEXT X1 (15.45 seconds IQR: 8.35-21.1) (p < 0.05). The median operative torque values of ProTaper NEXT X1 (0.26 N.cm; IQR: 0.18-0.49) were significantly higher compared with EdgeFile X7 17/.04 (0.09 N.cm; IQR: 0.05-0.17) (p < 0.05). Conclusions Although no difference was found between the median peak torque values of ProTaper NEXT X1 and EdgeFile X7 17/.04 instruments, the operative torque and instrumentation time results were impacted by their different designs and alloys during clinical preparation of root canals
Fatigue resistance of new and used nickel-titanium rotary instruments: a comparative study
Aim of the present study was twofold. First, to evaluate in vitro, the performance of two different NiTi rotary instruments in one molar case; then, to evaluate their resistance to cyclic fatigue, compared to new ones
- …
