885 research outputs found
Five-year follow-up results of the PROFHER trial comparing operative and non-operative treatment of adults with a displaced fracture of the proximal humerus
AIMS: The PROximal Fracture of the Humerus Evaluation by Randomisation (PROFHER) randomised clinical trial compared the operative and non-operative treatment of adults with a displaced fracture of the proximal humerus involving the surgical neck. The aim of this study was to determine the long-term treatment effects beyond the two-year follow-up. PATIENTS AND METHODS: Of the original 250 trial participants, 176 consented to extended follow-up and were sent postal questionnaires at three, four and five years after recruitment to the trial. The Oxford Shoulder Score (OSS; the primary outcome), EuroQol 5D-3L (EQ-5D-3L), and any recent shoulder operations and fracture data were collected. Statistical and economic analyses, consistent with those of the main trial were applied. RESULTS: OSS data were available for 164, 155 and 149 participants at three, four and five years, respectively. There were no statistically or clinically significant differences between operative and non-operative treatment at each follow-up point. No participant had secondary shoulder surgery for a new complication. Analyses of EQ-5D-3L data showed no significant between-group differences in quality of life over time. CONCLUSION: These results confirm that the main findings of the PROFHER trial over two years are unchanged at five years. Cite this article: Bone Joint J 2017;99-B:383-92
Axillary artery compromise in a minimally displaced proximal humerus fracture: a case report
Minimally displaced fractures of the surgical neck of the humerus are rarely associated with axillary artery injury. The innocuous appearance of the x-rays can be misleading and a missed arterial injury in these fractures could potentially lead to disastrous consequences. We report the case of a patient who sustained a minimally displaced fracture of the proximal humerus with vascular compromise requiring immediate investigation and referral to vascular surgeons. Despite spontaneous resolution of the vascular insult, it is important to remember the association of such fractures with vascular injuries in order to diagnose them early and prevent serious complications including amputation
Subacromial impingement in patients with whiplash injury to the cervical spine
<p>Abstract</p> <p>Background</p> <p>Impingement syndrome and shoulder pain have been reported to occur in a proportion of patients following whiplash injuries to the neck. In this study we aim to examine these findings to establish the association between subacromial impingement and whiplash injuries to the cervical spine.</p> <p>Methods and results</p> <p>We examined 220 patients who had presented to the senior author for a medico-legal report following a whiplash injury to the neck. All patients were assessed for clinical evidence of subacromial impingement. 56/220 patients (26%) had developed shoulder pain following the injury; of these, 11/220 (5%) had clinical evidence of impingement syndrome. Only 3/11 patients (27%) had the diagnosis made prior to evaluation for their medico-legal report. In the majority, other clinicians had overlooked the diagnosis. The seatbelt shoulder was involved in 83% of cases (p < 0.03).</p> <p>Conclusion</p> <p>After a neck injury a significant proportion of patients present with shoulder pain, some of whom have treatable shoulder pathology such as impingement syndrome. The diagnosis is, however, frequently overlooked and shoulder pain is attributed to pain radiating from the neck resulting in long delays before treatment. It is important that this is appreciated and patients are specifically examined for signs of subacromial impingement after whiplash injuries to the neck. Direct seatbelt trauma to the shoulder is one possible explanation for its aetiology.</p
Indications for computed tomography (CT-) diagnostics in proximal humeral fractures: a comparative study of plain radiography and computed tomography
Multi-messenger observations of a binary neutron star merger
On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta
Reconstruction plate versus minimal invasive retrograde titanium elastic nail fixation for displaced midclavicular fractures
Protocol for the ProFHER (PROximal fracture of the humerus:Evaluation by randomisation) trial: A pragmatic multi-centre randomised controlled trial of surgical versus non-surgical treatment for proximal fracture of the humerus in adults
Background: Proximal humeral fractures, which occur mainly in older adults, account for approximately 4 to 5% of all fractures. Approximately 40% of these fractures are displaced fractures involving the surgical neck. Management of this group of fractures is often challenging and the outcome is frequently unsatisfactory. In particular it is not clear whether surgery gives better outcomes than non-surgical management. Currently there is much variation in the use of surgery and a lack of good quality evidence to inform this decision. Methods/Design: We aim to undertake a pragmatic UK-based multi-centre randomised controlled trial evaluating the effectiveness and cost-effectiveness of surgical versus standard non-surgical treatment for adults with an acute closed displaced fracture of the proximal humerus with involvement of the surgical neck. The choice of surgical intervention is left to the surgeon, who must use techniques that they are fully experienced with. This will avoid 'learning curve' problems. We will promote good standards of non-surgical care, similarly insisting on care-provider competence, and emphasize the need for comparable provision of rehabilitation for both groups of patients. We aim to recruit 250 patients from a minimum of 18 NHS trauma centres throughout the UK. These patients will be followed-up for 2 years. The primary outcome is the Oxford Shoulder Score, which will be collected via questionnaires completed by the trial participants at 6, 12 and 24 months. This is a 12-item condition-specific questionnaire providing a total score based on the person's subjective assessment of pain and activities of daily living impairment. We will also collect data for other outcomes, including general health measures and complications, and for an economic evaluation. Additionally, we plan a systematic collection of reasons for non-inclusion of eligible patients who were not recruited into the trial, and their baseline characteristics, treatment preferences and intended treatment. Discussion: This article presents the protocol for a multi-centre randomised controlled trial. It gives extensive details of, and the basis for, the chosen methods, and describes the key measures taken to avoid bias and to ensure validity.</p
Risk factors for revision after shoulder arthroplasty: 1,825 shoulder arthroplasties from the Norwegian Arthroplasty Register
Background and purpose Previous studies on shoulder arthroplasty have usually described small patient populations, and few articles have addressed the survival of shoulder implants. We describe the results of shoulder replacement in the Norwegian population (of 4.7 million) during a 12-year period. Trends in the use of shoulder arthroplasty during the study period were also investigated
Improvements in survival of the uncemented Nottingham Total Shoulder prosthesis: a prospective comparative study
<p>Abstract</p> <p>Background</p> <p>The uncemented Nottingham Total Shoulder Replacement prosthesis system (Nottingham TSR) was developed from the previous BioModular<sup>® </sup>shoulder prosthesis taking into consideration the causes of the initial implant's failure.</p> <p>We investigated the impact of changes in the design of Nottingham TSR prosthesis on its survivorship rate.</p> <p>Methods</p> <p>Survivorship analyses of three types of uncemented total shoulder arthroplasty prostheses (BioModular<sup>®</sup>, initial Nottingham TSR and current Nottingham TSR systems with 11, 8 and 4 year survivorship data respectively) were compared. All these prostheses were implanted for the treatment of disabling pain in the shoulder due to primary and secondary osteoarthritis or rheumatoid arthritis. Each type of the prosthesis studied was implanted in consecutive group of patients – 90 patients with BioModular<sup>® </sup>system, 103 with the initial Nottingham TSR and 34 patients with the current Nottingham TSR system.</p> <p>The comparison of the annual cumulative survivorship values in the compatible time range between the three groups was done according to the paired <it>t </it>test.</p> <p>Results</p> <p>The 8-year and 11-year survivorship rates for the initially used modified BioModular<sup>® </sup>uncemented prosthesis were relatively low (75.6% and 71.7% respectively) comparing to the reported survivorship of the conventional cemented implants. The 8-year survivorship for the uncemented Nottingham TSR prosthesis was significantly higher (81.8%), but still not in the desired range of above 90%, that is found in other cemented designs. Glenoid component loosening was the main factor of prosthesis failure in both prostheses and mainly occurred in the first 4 postoperative years. The 4-year survivorship of the currently re-designed Nottingham TSR prosthesis, with hydroxylapatite coating of the glenoid baseplate, was significantly higher, 93.1% as compared to 85.1% of the previous Nottingham TSR.</p> <p>Conclusion</p> <p>The initial Nottingham shoulder prosthesis showed significantly higher survivorship than the BioModular<sup>® </sup>uncemented prosthesis, but lower than expected. Subsequently re-designed Nottingham TSR system presented a high short term survivorship rate that encourages its ongoing use</p
- …
