19 research outputs found
2018 EHRA expert consensus statement on lead extraction: Recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: Endorsed by APHRS/HRS/LAHRS
N
PRE-EXTRACTION CULTURES IN CARDIAC IMPLANTABLE ELECTRONIC DEVICE (CIED) INFECTION: CLINICAL IMPLICATIONS FOR DEVICE EXTRACTION
PT099 Predicting the severity of cardiac device-related infections – Can the urgency for device extraction be risk stratified based on initial presentation?
PM074 Culture negative implantable electronic cardiac device related infections requiring extraction
PRE-EXTRACTION CULTURES IN CARDIAC IMPLANTABLE ELECTRONIC DEVICE (CIED) INFECTION: CLINICAL IMPLICATIONS FOR DEVICE EXTRACTION
PW001 Cardiac electronic device implantation infection - A comparison of patients with infections in newly implanted devices compared with those post generator change or device upgrade
2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS
Unearthing the Evidence:Post-Mortem Interrogation of Cardiac Implantable Electronic Devices
Clinical practice and implementation of guidelines for the prevention, diagnosis and management of cardiac implantable electronic device infections: results of a worldwide survey under the auspices of the European Heart Rhythm Association
Aims Cardiac implantable electronic device (CIED) infection rates are increasing. Worldwide compliance and disparities to published guidelines for the prevention, diagnosis and management of these conditions are not well elucidated. The purpose of this survey, therefore, was to clarify these issues through an inquiry to arrhythmia-related associations and societies worldwide. Methods and results A questionnaire comprising 15 questions related to CIED infections was distributed among members of seven arrhythmia societies worldwide. A total of 234 centres in 62 countries reported implantation rates of which 159 (68.0%) performed more than 200 device implantations per year and 14 (6.0%) performed fewer than 50 implantations per year. The reported rates of CIED infections for 2017 were Conclusion Clinical practices for prevention and management of CIED do not fully comply with current recommendations and demonstrate considerable regional disparities. Further education and programmes for improved implementation of guidelines are mandatory
