    Airway compliance measured by anatomic optical coherence tomography

    Get PDF
    Quantification of airway compliance can aid in the diagnosis and treatment of obstructive airway disorders by detecting regions vulnerable to collapse. Here we evaluate the ability of a swept-source anatomic optical coherence tomography (SSaOCT) system to quantify airway cross-sectional compliance (CC) by measuring changes in the luminal cross-sectional area (CSA) under physiologically relevant pressures of 10–40 cmH2O. The accuracy and precision of CC measurements are determined using simulations of non-uniform rotation distortion (NURD) endemic to endoscopic scanning, and experiments performed in a simplified tube phantom and ex vivo porcine tracheas. NURD simulations show that CC measurements are typically more accurate than that of the CSAs from which they are derived. Phantom measurements of CSA versus pressure exhibit high linearity (R2>0.99), validating the dynamic range of the SSaOCT system. Tracheas also exhibited high linearity (R2 = 0.98) suggestive of linear elasticity, while CC measurements were obtained with typically ± 12% standard error

    Automated algorithm for breast tissue differentiation in optical coherence tomography

    Get PDF
    Abstract. An automated algorithm for differentiating breast tissue types based on optical coherence tomography ͑OCT͒ data is presented. Eight parameters are derived from the OCT reflectivity profiles and their means and covariance matrices are calculated for each tissue type from a training set ͑48 samples͒ selected based on histological examination. A quadratic discrimination score is then used to assess the samples from a validation set. The algorithm results for a set of 89 breast tissue samples were correlated with the histological findings, yielding specificity and sensitivity of 0.88. If further perfected to work in real time and yield even higher sensitivity and specificity, this algorithm would be a valuable tool for biopsy guidance and could significantly increase procedure reliability by reducing both the number of nondiagnostic aspirates and the number of false negatives

    Quantitative upper airway endoscopy with swept-source anatomical optical coherence tomography

    Get PDF
    Minimally invasive imaging of upper airway obstructions in children and adults is needed to improve clinical decision-making. Toward this goal, we demonstrate an anatomical optical coherence tomography (aOCT) system delivered via a small-bore, flexible endoscope to quantify the upper airway lumen geometry. Helical scans were obtained from a proximally-scanned fiber-optic catheter of 820 μm outer diameter and >2 mm focal length. Coupled with a long coherence length wavelength-swept light source, the system exhibited an SNR roll-off of < 10 dB over a 10 mm range. Operating at 10 rotations/s, the average accuracy of segmented cross-sectional areas was found to be −1.4 ± 1.0%. To demonstrate the capability of this system, aOCT was performed on a pediatric airway phantom and on ex vivo swine trachea. The ability for quantitative endoscopy afforded by this system can aid in diagnosis, medical and surgical decision making, and predictive modeling of upper airway obstructive disorders

    Imaging flow dynamics in murine coronary arteries with spectral domain optical Doppler tomography

    Get PDF
    Blood flow in murine epicardial and intra-myocardial coronary arteries was measured in vivo with spectral domain optical Doppler tomography (SD-ODT). Videos at frame rates up to 180 fps were collected and processed to extract phase shifts associated with moving erythrocytes in the coronary arteries. Radial averaging centered on the vessel lumen provided spatial smoothing of phase noise in a single cross-sectional frame for instantaneous peak velocity measurement without distortion of the flow profile. Temporal averaging synchronized to the cardiac cycle (i.e., gating) was also performed to reduce phase noise, although resulting in lower flow profiles. The vessel angle with respect to incident imaging beam was measured with three-dimensional raster scans collected from the same region as the high speed cross-sectional scans. The variability in peak phase measurement was 10-15% from cycle to cycle on a single animal but larger for measurements among animals. The inter-subject variability is attributed to factors related to real physiological and anatomical differences, instrumentation variables, and measurement error. The measured peak instantaneous flow velocity in a ~40-µm diameter vessel was 23.5 mm/s (28 kHz Doppler phase shift). In addition to measurement of the flow velocity, we observed several dynamic features of the vessel and surrounding myocardium in the intensity and phase sequences, including asymmetric vessel deformation and rapid flow reversal immediately following maximum flow, in confirmation of known coronary artery flow dynamics. SD-ODT is an optical imaging tool that can provide in vivo measures of structural and functional information on cardiac function in small animals

    Tracking adaptive optics scanning laser ophthalmoscope

    Get PDF
    ABSTRACT Active image stabilization for an adaptive optics scanning laser ophthalmoscope (AOSLO) was developed and tested in human subjects. The tracking device, a high speed, closed-loop optical servo which uses retinal features as tracking target, is separate from AOSLO optical path. The tracking system and AOSLO beams are combined via a dichroic beam splitter in front of the eye. The primary tracking system galvanometer mirrors follow the motion of the eye. The AOSLO raster is stabilized by a secondary set of galvanometer mirrors in the AOSLO optical train which are &quot;slaved&quot; to the primary mirrors with fixed scaling factors to match the angular gains of the optical systems. The AO system (at 830 nm) uses a MEMS-based deformable mirror (Boston Micromachines Inc.) for wave-front correction. The third generation retinal tracking system achieves a bandwidth of greater than 1 kHz allowing acquisition of stabilized AO images with an accuracy of &lt;10 µm. However, such high tracking bandwidth, required for tracking saccades, results in finite tracking position noise which is evident in AOSLO images. By means of filtering algorithms, the AOSLO raster is made to follow the eye accurately with reduced tracking noise artifacts. The system design includes simultaneous presentation of non-AO, wide-field (~40 deg) live reference image captured with a line scanning laser ophthalmoscope (LSLO) typically operating from 900 to 940 nm. High-magnification (1-2 deg) AOSLO retinal scans easily positioned on the retina in a drag-and-drop manner. Normal adult human volunteers were tested to optimize the tracking instrumentation and to characterize AOSLO imaging performance. Automatic blink detection and tracking re-lock, enabling reacquisition without operator intervention, were also tested. The tracking-enhanced AOSLO may become a useful tool for eye research and for early detection and treatment of retinal diseases

    The potential utility of integrated reflectance confocal microscopy-optical coherence tomography for guiding triage and therapy of basal cell carcinomas.

    Get PDF
    The increasing rate of incidence and prevalence of basal cell carcinomas (BCCs) worldwide, combined with the morbidity associated with conventional surgical treatment has led to the development and use of alternative minimally invasive non-surgical treatments. Biopsy and pathology are used to guide BCC diagnosis and assess margins and subtypes, which then guide the decision and choice of surgical or non-surgical treatment. However, alternatively, a noninvasive optical approach based on combined reflectance confocal microscopy (RCM) and optical coherence tomography (OCT) imaging may be used. Optical imaging may be used to guide diagnosis and margin assessment at the bedside, and potentially facilitate non-surgical management, along with long-term monitoring of treatment response. Noninvasive imaging may also complement minimally invasive treatments and help further reduce morbidity. In this paper, we highlight the current state of an integrated RCM/OCT imaging approach for diagnosis and triage of BCCs, as well as for assessing margins, which therefore may be ultimately used for guiding therapy.AMSUNY DownstatePathologyN/

    Angulated small nests and cords: Key diagnostic histopathologic features of infiltrative basal cell carcinoma can be identified using integrated reflectance confocal microscopy-optical coherence tomography.

    Get PDF
    Background: Accurate basal cell carcinoma (BCC) subtyping is requisite for appropriate management, but non-representative sampling occurs in 18% to 25% of biopsies. By enabling non-invasive diagnosis and more comprehensive sampling, integrated reflectance confocal microscopy-optical coherence tomography (RCM-OCT) may improve the accuracy of BCC subtyping and subsequent management. We evaluated RCM-OCT images and histopathology slides for the presence of two key features, angulation and small nests and cords, and calculated (a) sensitivity and specificity of these features, combined and individually, for identifying an infiltrative BCC subtype and (b) agreement across modalities. Methods: Thirty-three RCM-OCT-imaged, histopathologically-proven BCCs (17 superficial and/or nodular; 16 containing an infiltrative component) were evaluated. Results: The presence of angulation or small nests and cords was sufficient to identify infiltrative BCC on RCM-OCT with 100% sensitivity and 82% specificity, similar to histopathology (100% sensitivity, 88% specificity, kappa = 0.82). When both features were present, the sensitivity for identifying infiltrative BCC was 100% using either modality and specificity was 88% on RCM-OCT vs 94% on histopathology, indicating near-perfect agreement between non-invasive and invasive diagnostic modalities (kappa = 0.94). Conclusions: RCM-OCT can non-invasively identify key histopathologic features of infiltrative BCC offering a possible alternative to traditional invasive biopsy.AMSUNY DownstatePathologyN/

    Evaluation of a Combined Reflectance Confocal Microscopy-Optical Coherence Tomography Device for Detection and Depth Assessment of Basal Cell Carcinoma.

    Get PDF
    Importance: The limited tissue sampling of a biopsy can lead to an incomplete assessment of basal cell carcinoma (BCC) subtypes and depth. Reflectance confocal microscopy (RCM) combined with optical coherence tomography (OCT) imaging may enable real-time, noninvasive, comprehensive three-dimensional sampling in vivo, which may improve the diagnostic accuracy and margin assessment of BCCs. Objective: To determine the accuracy of a combined RCM-OCT device for BCC detection and deep margin assessment. Design, setting, and participants: This pilot study was carried out on 85 lesions from 55 patients referred for physician consultation or Mohs surgery at Memorial Sloan Kettering Skin Cancer Center in Hauppauge, New York. These patients were prospectively and consecutively enrolled in the study between January 1, 2017, and December 31, 2017. Patients underwent imaging, with the combined RCM-OCT probe, for previously biopsied, histopathologically confirmed BCCs and lesions clinically or dermoscopically suggestive of BCC. Only patients with available histopathologic examination after imaging were included. Main outcomes and measures: Improvements in sensitivity, specificity, and diagnostic accuracy for BCC using the combined RCM-OCT probe as well as the correlation between OCT-estimated depth and histopathologically measured depth were investigated. Results: In total, 85 lesions from 55 patients (27 [49%] were female and 28 [51%] were male with a median [range] age of 59 [21-90] years) were imaged. Imaging was performed on 25 previously biopsied and histopathologically confirmed BCCs and 60 previously nonbiopsied but clinically or dermoscopically suspicious lesions. Normal skin and BCC features were correlated and validated with histopathologic examination. In previously biopsied lesions, residual tumors were detected in 12 of 25 (48%) lesions with 100% sensitivity (95% CI, 73.5%-100%) and 23.1% specificity (95% CI, 5.0%-53.8%) for combined RCM-OCT probe. In previously nonbiopsied and suspicious lesions, BCCs were diagnosed in 48 of 60 (80%) lesions with 100% sensitivity (95% CI, 92.6%-100%) and 75% specificity (95% CI, 42.8%-94.5%). Correlation was observed between depth estimated with OCT and depth measured with histopathologic examination: the coefficient of determination (R2) was 0.75 (R = 0.86; P < .001) for all lesions, 0.73 (R = 0.85; P < .001) for lesions less than 500 μm deep, and 0.65 (R = 0.43; P < .001) for lesions greater than 500 μm deep. Conclusions and relevance: Combined RCM-OCT imaging may be prospectively used to comprehensively diagnose lesions suggestive of BCC and triage for treatment. Further validation of this device must be performed on a larger cohort.VoRSUNY DownstatePathologyN/

    Medical optics and biotechnology; (170.4500) Optical coherence tomography; (170.3880) Medical and biological imaging

    Get PDF
    Abstract: We have developed a dual-beam Fourier domain optical Doppler tomography (FD-ODT) system to image zebrafish (Danio rerio) larvae. Two beams incident on the zebrafish with a fixed angular separation allow absolute blood flow velocity measurement to be made regardless of vessel orientation in a sagittal plane along which the heart and most of the major vasculature lie. Two spectrometers simultaneously acquire spectra from two interferometers with a typical (maximum) line rate of 18 (28) kHz. The system was calibrated using diluted milk and microspheres and a 0.5-mm thick flow cell. The average deviation from the set velocity from 1.4 to 34.6 mm/s was 4.1%. Three-dimensional structural raster videos were acquired of an entire fish, and through the head, heart, and upper tail of the fish. Coarse features that were resolved include the telencephalon, retina, both heart chambers (atrium and ventricle), branchial arches, and notochord. Other fine structures within these organs were also resolved. Zebrafish are an important tool for high-throughput screening of new pharmacological agents. The ability to generate high-resolution three-dimensional structural videos and accurately measure absolute flow rates in major vessels with FD-ODT provides researchers with additional metrics by which the efficacy of new drugs can be assessed