282 research outputs found

    Intrinsic switching field distribution of arrays of Ni80Fe20 nanowires probed by insitu\mathit{in\, situ} magnetic force microscopy

    Full text link
    The progress of magnetization reversal of weakly packed ferromagnetic Ni80Fe20 nanowire arrays of different diameters (40, 50, 70 and 100 nm) electrodeposited in polycarbonate membranes was studied by magnetic force microscopy (MFM). For such a low packing density of nanomagnets, the dipolar interactions between neighbouring wires can be neglected. The intrinsic switching field distribution has been extracted from in situ MFM images and its width was found to be considerably smaller than for densely packed nanowire arrays.Comment: 4 pages, 5 figures. To appear in Journal of Superconductivity and Novel Magnetis

    Magnetic force microscopy investigation of arrays of nickel nanowires and nanotubes

    Full text link
    The magnetic properties of arrays of nanowires (NWs) and nanotubes (NTs), 150 nm in diameter, electrodeposited inside nanoporous polycarbonate membranes are investigated. The comparison of the nanoscopic magnetic force microscopy (MFM) imaging and the macroscopic behavior as measured by alternating gradient force magnetometry (AGFM) is made. It is shown that MFM is a complementary technique that provides an understanding of the magnetization reversal characteristics at the microscopic scale of individual nanostructures. The local hysteresis loops have been extracted by MFM measurements. The influence of the shape of such elongated nanostructures on the dipolar coupling and consequently on the squareness of the hysteresis curves is demonstrated. It is shown that the nanowires exhibit stronger magnetic interactions than nanotubes. The non-uniformity of the magnetization states is also revealed by combining the MFM and AGFM measurements.Comment: 7 pages, 5 figure

    Novel Data Acquisition System for Silicon Tracking Detectors

    Full text link
    We have developed a novel data acquisition system for measuring tracking parameters of a silicon detector in a particle beam. The system is based on a commercial Analog-to-Digital VME module and a PC Linux based Data Acquisition System. This DAQ is realized with C++ code using object-oriented techniques. Track parameters for the beam particles were reconstructed using off-line analysis code and automatic detector position alignment algorithm. The new DAQ was used to test novel Czochralski type silicon detectors. The important silicon detector parameters, including signal size distributions and signal to noise distributions, were successfully extracted from the detector under study. The efficiency of the detector was measured to be 95 %, the resolution about 10 micrometers, and the signal to noise ratio about 10.Comment: Talk from the 2003 Computing in High Energy and Nuclear Physics (CHEP03), La Jolla, Ca, USA, March 2003, 6 pages, LaTeX, 5 eps figures. PSN TUGP00

    A hybrid (Al)GaAs-LiNbO3 surface acoustic wave resonator for cavity quantum dot optomechanics

    Get PDF
    A hybrid device comprising a (Al)GaAs quantum dot heterostructure and a LiNbO3_3 surface acoustic wave resonator is fabricated by heterointegration. High acoustic quality factors Q>4000Q>4000 are demonstrated for an operation frequency f300f\approx 300 MHz. The measured large quality factor-frequency products Q×f>1012Q\times f>10^{12} ensures the suppression of decoherence due to thermal noise for temperatures exceeding T>50KT>50\,\mathrm{K}. Frequency and position dependent optomechanical coupling of single quantum dots and the resonator modes is observed.Comment: Accepted manuscrip

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented
    corecore