35 research outputs found

    Titanium based cranial reconstruction using incremental sheet forming

    Get PDF
    In this paper, we report recent work in cranial plate manufacturing using incremental sheet forming (ISF) process. With a typical cranial shape, the ISF process was used to manufacture the titanium cranial shape by using different ISF tooling solutions with and without backing plates. Detailed evaluation of the ISF process including material deformation and thinning, geometric accuracy and surface finish was conducted by using a combination of experimental testing and Finite Element (FE) simulation. The results show that satisfactory cranial shape can be achieved with sufficient accuracy and surface finish by using a feature based tool path generation method and new ISF tooling design. The results also demonstrate that the ISF based cranial reconstruction has the potential to achieve considerable lead time reduction as compared to conventional methods for cranial plate manufacturing. This outcome indicates that there is a potential for the ISF process to achieve technological advances and economic benefits as well as improvement to quality of life

    The SECOQC quantum key distribution network in Vienna

    Get PDF
    In this paper, we present the quantum key distribution (QKD) network designed and implemented by the European project SEcure COmmunication based on Quantum Cryptography (SECOQC) (2004–2008), unifying the efforts of 41 research and industrial organizations. The paper summarizes the SECOQC approach to QKD networks with a focus on the trusted repeater paradigm. It discusses the architecture and functionality of the SECOQC trusted repeater prototype, which has been put into operation in Vienna in 2008 and publicly demonstrated in the framework of a SECOQC QKD conference held from October 8 to 10, 2008. The demonstration involved one-time pad encrypted telephone communication, a secure (AES encryption protected) video-conference with all deployed nodes and a number of rerouting experiments, highlighting basic mechanisms of the SECOQC network functionality.The paper gives an overview of the eight point-to-point network links in the prototype and their underlying technology: three plug and play systems by id Quantique, a one way weak pulse system from Toshiba Research in the UK, a coherent one-way system by GAP Optique with the participation of id Quantique and the AIT Austrian Institute of Technology (formerly ARCAustrian Research Centers GmbH—ARC is now operating under the new name AIT Austrian Institute of Technology GmbH following a restructuring initiative.), an entangled photons system by the University of Vienna and the AIT, a continuous-variables system by Centre National de la Recherche Scientifique (CNRS) and THALES Research and Technology with the participation of Université Libre de Bruxelles, and a free space link by the Ludwig Maximillians University in Munich connecting two nodes situated in adjacent buildings (line of sight 80 m). The average link length is between 20 and 30 km, the longest link being 83 km.The paper presents the architecture and functionality of the principal networking agent—the SECOQC node module, which enables the authentic classical communication required for key distillation, manages the generated key material, determines a communication path between any destinations in the network, and realizes end-to-end secure transport of key material between these destinations.The paper also illustrates the operation of the network in a number of typical exploitation regimes and gives an initial estimate of the network transmission capacity, defined as the maximum amount of key that can be exchanged, or alternatively the amount of information that can be transmitted with information theoretic security, between two arbitrary nodes

    What are the limitations of the non-patient-specific implant in titanium reconstruction of the orbit?

    No full text
    There is ongoing discussion about patient-specific implants (PSI) to reconstruct orbital defects. Although PSI offer excellent clinical outcome, they are expensive. Subsequently, their routine application is not indicated. The purpose of this study was to estimate the frequency of implant malposition and revision procedures after primary orbital repair with preformed plates and to identify cases where primary use of PSI would help to prevent revision surgery. All patients included in the study were operated on for orbital fractures at the Royal London Hospital between August 2017 and July 2018. Selection criteria included adult patients treated for orbital fractures with a titanium plate. Revision was planned in symptomatic patients presenting with clear implant malposition. Seventy-nine patients with 81 implants were included, 33 of whom had multiple orbital wall fractures (medial wall and floor or all four walls) and were summarised as group 2. Group 1 consisted of single orbital floor/medial wall fractures. The five patients for whom revision surgery was planned or undertaken because of radiological poorly positioned implants and substantial clinical symptoms all had multiple wall fractures. This finding was significant (p = 0.006). The major reason for revision was a defect that was too large for the prescribed plate. Patients with large orbital defects needing surgical treatment are at risk of implant malposition. The orbital reconstruction with preformed plate evidences good outcome in single wall fractures. However, the risk of malposition increases massively with fracture size. We therefore postulate that in large, two-wall fractures, primary treatment with a PSI has to be considered

    Primary tuberculosis of the TMJ: presentation of a case and literature review

    No full text
    Tuberculosis (TB) is a frequent health problem. The prevalence of extrapulmonary TB has increased in the last couple of years. Head and neck tuberculosis forms nearly 10% of all extrapulmonary manifestations of the disease. TB of the temporomandibular joint (TMJ) is rare; only a few cases have been reported. The clinical appearance of TB infection of the TMJ has been described as unspecific, resembling arthritis, osteomyelitis, cancer or any kind of chronic joint diseases. This article describes a 22-year-old woman with pain and left preauricular swelling. Magnetic resonance imaging and computed tomography showed an expansive process with destruction of the left condyle and condylar fossa. A fine needle aspiration examination of the swelling showed non-specific granulomatous inflammation. In the following days, a preauricular fistula developed, of which a swab and biopsy specimens were taken. Histological and microbiological examinations revealed an infection with Mycobacterium tuberculosis. The initial antituberculosis treatment consisted of a combination of four antibiotics and could be reduced to two antibiotics in the course of treatment. The treatment was completed successfully after 9 months
    corecore