    2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: executive summary.

    Get PDF
    S

    Remote magnetic versus manual catheters: evaluation of ablation effect in atrial fibrillation by myocardial marker levels

    Get PDF
    Background A remote magnetic navigation (MN) system is available for radiofrequency ablation of atrial fibrillation (AF), challenging the conventional manual ablation technique. The myocardial markers were measured to compare the effects of the two types of MN catheters with those of a manual-irrigated catheter in AF ablation. Methods AF patients underwent an ablation procedure using either a conventional manual-irrigated catheter (CIR, n=65) or an MN system utilizing either an irrigated (RMI, n=23) or non-irrigated catheter (RMN, n=26). Levels of troponin T (TnT) and the cardiac isoform of creatin kinase (CKMB) were measured before and after ablation. Results Mean procedure times and total ablation times were longer employing the remote magnetic system. In all groups, there were pronounced increases in markers of myocardial injury after ablation, demonstrating a significant correlation between total ablation time and post-ablation levels of TnT and CKMB (CIR r=0.61 and 0.53, p<0.001; RMI r=0.74 and 0.73, p<0.001; and RMN r=0.51 and 0.59, p<0.01). Time-corrected release of TnT was significantly higher in the CIR group than in the other groups. Of the patients, 59.6% were free from AF at follow-up (12.2± 5.4 months) and there were no differences in success rate between the three groups. Conclusions Remote magnetic catheters may create more discrete and predictable ablation lesions measured by myocardial enzymes and may require longer total ablation time to reach the procedural endpoints. Remote magnetic non-irrigated catheters do not appear to be inferior to magnetic irrigated catheters in terms of myocardial enzyme release and clinical outcome

    Direct cooling of the catheter tip increases safety for CMR-guided electrophysiological procedures

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>One of the safety concerns when performing electrophysiological (EP) procedures under magnetic resonance (MR) guidance is the risk of passive tissue heating due to the EP catheter being exposed to the radiofrequency (RF) field of the RF transmitting body coil. Ablation procedures that use catheters with irrigated tips are well established therapeutic options for the treatment of cardiac arrhythmias and when used in a modified mode might offer an additional system for suppressing passive catheter heating.</p> <p>Methods</p> <p>A two-step approach was chosen. Firstly, tests on passive catheter heating were performed in a 1.5 T Avanto system (Siemens Healthcare Sector, Erlangen, Germany) using a ASTM Phantom in order to determine a possible maximum temperature rise. Secondly, a phantom was designed for simulation of the interface between blood and the vascular wall. The MR-RF induced temperature rise was simulated by catheter tip heating via a standard ablation generator. Power levels from 1 to 6 W were selected. Ablation duration was 120 s with no tip irrigation during the first 60 s and irrigation at rates from 2 ml/min to 35 ml/min for the remaining 60 s (Biotronik Qiona Pump, Berlin, Germany). The temperature was measured with fluoroscopic sensors (Luxtron, Santa Barbara, CA, USA) at a distance of 0 mm, 2 mm, 4 mm, and 6 mm from the catheter tip.</p> <p>Results</p> <p>A maximum temperature rise of 22.4°C at the catheter tip was documented in the MR scanner. This temperature rise is equivalent to the heating effect of an ablator's power output of 6 W at a contact force of the weight of 90 g (0.883 N). The catheter tip irrigation was able to limit the temperature rise to less than 2°C for the majority of examined power levels, and for all examined power levels the residual temperature rise was less than 8°C.</p> <p>Conclusion</p> <p>Up to a maximum of 22.4°C, the temperature rise at the tissue surface can be entirely suppressed by using the catheter's own irrigation system. The irrigated tip system can be used to increase MR safety of EP catheters by suppressing the effects of unwanted passive catheter heating due to RF exposure from the MR scanner.</p

    The symbiosis of contact force catheter use for hybrid ablation for atrial fibrillation

    Get PDF
    Objective Reconduction across an ablation line is a common reason for arrhythmia recurrence over time. The hybrid procedure combines epicardial ablation of the pulmonary vein (PV) and creation of a box lesion with endocardial touch-ups for any electrical gaps. A high contact force (CF) between the ablation tip and cardiac tissue may increase the risk of thrombus formation, catheter tip charring, steam pop formation, and even cardiac perforation. CF monitoring is a significant new parameter for titration of the CF for creating an adequate lesion. Methods Thirty-eight consecutive patients underwent epicardial ablation using bipolar radiofrequency devices. After checking electrical bidirectional block of the ablation lines, an endocardial CF catheter was used for further ablation (if needed) to complete the isolation of PVs, box lesion, cavotricuspid isthmus (CTI), and complex fractionated atrial electrograms (CFAE). Results Endocardial touch-up was needed for 2 PVs (1.3 %) and 10 (26.3 %) box lesions. It was also used for the CTI line in 7 (18.4 %) patients, atrial tachycardia in 3 (7.9 %) patients, and additional CFAE ablation in 17 (44.7 %) patients. All 5 patients with arrhythmia recurrence had a mean CF <10 g (p = 0.03). Procedure duration was significantly shorter in the CF group (223 +/- 57 vs. 256 +/- 60 min, p = 0.03) compared with control group. Conclusion Use of CF catheters is safe, feasible, and complementary to a hybrid procedure setup for atrial fibrillation ablation. Its real-time monitoring may predict future arrhythmia recurrence, and decrease procedure time

    Scar nonexcitability using simultaneous pacing for substrate ablation of ventricular tachycardia

    No full text
    OBJECTIVES: To describe an expedited strategy of simultaneous high-output pacing during radiofrequency ablation to achieve scar homogenization and electrical inexcitability as an approach for substrate ablation for scar-related ventricular tachycardia (VT). BACKGROUND: Scar homogenization with additional testing for electrical inexcitability is known endpoints for catheter ablation, but achieving both can be time consuming. We describe a strategy of simultaneous pacing during radiofrequency ablation to expedite this approach. METHODS AND RESULTS: Ten patients (age 74 ± 6 years; all men, (LV) ejection fraction of 33% ± 8%, ischemic cardiomyopathy, 9; VT storm, 7) underwent scar homogenization with electrical inexcitability to pacing (10 mA, 9 ms pulse width), as well as noninducibility of any VT as an acute procedural endpoint. Thirty-four VTs were inducible in 10 patients with a total of 1127 ablation lesions applied. Median ablation lesions per patient were 97 (interquartile range [IQR]25-75 71-151), and the total ablation time was 49 minutes (IQR25-75 45-56 minutes) with average duration per lesion of 32.2 seconds (IQR25-75 25.8-37.8 seconds). Average power was 33 W (IQR25-75 32-38 W), average contact force was 13 g (IQR25-75 11.9-14.6 g) with a median impedance drop of 9.6 Ω/lesion (IQR25-75 8.1-10.0 Ω). There were no ventricular fibrillation episodes using this strategy. The median procedure time was 246 minutes (IQR25-75 214-293 minutes). Acute procedural success was seen in nine patients with 97% of VTs noninducible. CONCLUSION: Simultaneous ablation with high output pacing to achieve scar inexcitability, when combined with scar homogenization and noninducibility of any VT may be an expeditious, safe, and effective technique for catheter ablation