3,054 research outputs found
Radiation Hardness tests with neutron flux on different Silicon photomultiplier devices
Radiation hardness is an important requirement for solid state readout
devices operating in high radiation environments common in particle physics
experiments. The MEGII experiment, at PSI, Switzerland, investigates the
forbidden decay . Exploiting the most intense
muon beam of the world. A significant flux of non-thermal neutrons (kinetic
energy ) is present in the experimental hall produced along
the beamline and in the hall itself. We present the effects of neutron fluxes
comparable to the MEGII expected doses on several Silicon PhotoMulitpliers
(SiPMs). The tested models are: AdvanSiD ASD-NUV3S-P50 (used in MEGII
experiment), AdvanSiD ASD-NUV3S-P40, AdvanSiD ASD-RGB3S-P40, Hamamatsu and
Excelitas C30742-33-050-X. The neutron source is the thermal Sub-critical
Multiplication complex (SM1) moderated with water, located at the University of
Pavia (Italy). We report the change of SiPMs most important electric
parameters: dark current, dark pulse frequency, gain, direct bias resistance,
as a function of the integrated neutron fluency.Comment: 9 pages, 6 figures. Proceedings from Instrumentation for colliding
Beam Physics (INSTR-17) 27-02-2017/03-03-2017 Novosibirsk (R
CCD Washington photometry of four poorly studied open clusters in the two inner quadrants of the galactic plane
Complementing our Washington photometric studies on Galactic open clusters
(OCs), we now focus on four poorly studied OCs located in the first and fourth
Galactic quadrants, namely BH 84, NGC 5381, BH 211 and Czernik 37. We have
obtained CCD photometry in the Washington system and passbands down
to 18.5 magnitudes for these four clusters. Their positions and
sizes were determined using the stellar density radial profiles. We derived
reddening, distance, age and metallicity of the clusters from extracted
color-magnitude diagrams (CMDs), using theoretical isochrones
computed for the Washington system. There are no previous photometric data in
the optical band for BH 84, NGC 5381 and BH 211. The CMDs of the observed
clusters show relatively well defined main sequences, except for Czernik 37,
wherein significant differential reddening seems to be present. The red giant
clump is clearly seen only in BH 211. For this cluster, we estimated the age in
(1000) Myr, assuming a metallicity of = 0.019. BH 84 was
found to be much older than it was previously believed, while NGC 5381 happened
to be much younger than previously reported. The heliocentric distances to
these clusters are found to range between 1.4 and 3.4 kpc. BH 84 appears to be
located at the solar galactocentric distance, while NGC 5381, BH 211 and
Czernik 37 are situated inside the solar ring.Comment: 30 pages, 9 figures, 10 table
Dark interlayer plasmons in colloidal gold nanoparticle bi- and few-layers
We demonstrate the excitation of dark plasmon modes with linearly polarized light at normal incidence in self-assembled layers of gold nanoparticles. Because of field retardation, the incident light field induces plasmonic dipoles that are parallel within each layer but antiparallel between the layers, resulting in a vanishing net dipole moment. Using microabsorbance spectroscopy we measured a pronounced absorbance peak and reflectance dip at 1.5 eV for bi- and trilayers of gold nanoparticles with a diameter of 46 nm and 2 nm interparticle gap size. The excitations were identified as dark interlayer plasmons by finite-difference time-domain simulations. The dark plasmon modes are predicted to evolve into standing waves when further increasing the layer number, which leads to 90% transmittance of the incident light through the nanoparticle film. Our approach is easy to implement and paves the way for large-area coatings with tunable plasmon resonance
Interleukin-1beta tear concentration in glaucomatous and ocular hypertensive patients treated with preservative-free nonselective beta-blockers
PURPOSE: To evaluate the ocular surface inflammatory response to the presence of preservatives in nonselective
beta-blocker eyedrops.
DESIGN: Prospective, crossover, single-masked, randomized
clinical study. METHODS: STUDY POPULATION: Twenty primary open angle glaucoma or ocular hypertensive patients were divided in two groups, one treated with preservative-free timolol 0.5% (group 1) and the other with preserved timolol 0.5% (group 2) eyedrops. After 60 days of therapy and 3 more weeks of washout, the two groups switched to the other therapy. PROCEDURE: At each visit,basal tear samples were collected from the inferior conjunctival fornix for the determination of interleukin (IL)-1 tear concentrations by an enzyme-linked immunosorbent assay. Intraocular pressure measurement, conjunctival
hyperemia, superficial punctate keratitis, and tear film breakup time were evaluated. MAIN OUTCOME MEASURE: IL-1 concentration in tears following the use of preserved eyedrops.
RESULTS: IL-1 tear concentrations increased significantly in both groups, compared with baseline values,during preserved timolol therapy. There were no statistically significant changes in hyperemia and superficial punctate keratitis throughout the study in either group.A statistically significant breakup time reduction was observed in both groups after 30 days and after 60 days of preserved therapy.
CONCLUSION: The use of preservatives in timolol 0.5% eyedrops leads to tear film instability and ocular surface inflammatory changes documented by a reduction of breakup time and an increase of IL-1 tear concentrations.Preservative-free beta-blockers are preferable for long-term hypotensive therapy to prevent ocular surface inflammation
Parallel hardware architectures for the cryptographic Tate pairing
Identity-based cryptography uses pairing functions, which
are sophisticated bilinear maps defined on elliptic
curves. Computing pairings efficiently in software is
presently a relevant research topic. Since such functions
are very complex and slow in software, dedicated hard-
ware (HW) implementations are worthy of being stud-
ied, but presently only very preliminary research is avail-
able. This work affords the problem of designing paral-
lel dedicated HW architectures, i.e.,co-processors, for the
Tate pairing, in the case of the Duursma-Lee algorithm
in characteristic 3. Formal scheduling methodologies are
applied to carry out an extensive exploration of the archi-
tectural solution space, evaluating the obtained structures
by means of different figures of merit such as computation
time, circuit area and combinations thereof.Comparisons
with the (few) existing proposals are carried out, show-
ing that a large space exists for the efficient parallelHW
computation of pairings
Exploring the Heidelberg Retinal Tomograph 3 diagnostic accuracy across disc sizes and glaucoma stages: a multicenter study
To investigate and compare the diagnostic accuracy of the Heidelberg Retinal Tomograph 3 (HRT3) diagnostic algorithms and establish whether they are affected by optic disc size and glaucoma severity
Prevention of Dermatologic Side Effects of Bimatoprost 0.03% Topical Therapy
PURPOSE: To investigate the efficacy of reducing the drop-skin contact to prevent dermatologic side effects of bimatoprost 0.03% topical therapy. DESIGN: Prospective, randomized, single-blinded, internally controlled study. METHODS: Enrolled subjects started bimatoprost 0.03% therapy once at night in both eyes and were instructed to wipe selectively only one eye (eye 1) with an adsorbent pad during and after drops administration for four months. The fellow eye acted as the internal control. Eyelash growth, regional skin hypertrichosis, and pigmentation on the periocular skin were assessed at baseline and during the four months of follow-up. RESULTS: A lower incidence of eyelash growth and skin pigmentation in the inferonasal pericanthal region were observed in eye 1. The incidence of pigmentation in the inferotemporal skin region and skin hypertrichosis were similar in the two eyes. CONCLUSION: The reduction of the drop,skin contact affects the regional incidence and the extent of dermatologic skin changes that are related to bimatoprost 0.03% topical therapy
Learning effect of humphrey matrix frequency doubling technology perimetry in patients with ocular hypertension
Aim: To evaluate the learning effect of Frequency Doubling Technology (FDT) perimetry using the Humphrey Matrix-FDT perimetry (Matrix) 24-2 full-threshold program on patients with 7 ocular hypertension experienced with standard automated perimetry. Methods: Twenty-four patients with Ocular hypertension underwent 5 full-threshold Matrix tests at intervals of 5 2 days. Learning effect was defined as an improvement at results for duration, perimetric indices, foveal sensitivity, Glaucoma Hemifield Test, and the number of points with a P < 5% and < 1% in the total and pattern deviation maps. Eccentricity, hemifield, and quadrant sensitivities were also addressed as Sources of differences in learning effect. Test-retest variability was also calculated for each repetition as the mean of the point-to-point interindividual standard deviations. Results: A learning effect was demonstrated for mean defect (P = 0.031, analysis of variance) and foveal sensitivity (P = 0.009) and it only affected the first test for both parameters. All the other parameters did not show any significant learning effect. The effect was independent From eccentricity and quadrant or hemifield sensitivities. Conclusions: The results of this study demonstrate that the learning effect for Matrix-FDT is mild and it may affect only the first test. Caution is needed in the analysis of the first Matrix-FDT examination and retest may be advisable in the presence of low mean defect
The k 0-INRIM software: a tool to compile uncertainty budgets in neutron activation analysis based on k 0-standardisation
A software package was developed to evaluate the uncertainty of results provided by neutron activation laboratories adopting the k0-standardisation method in trace elements analysis.
The outputs are stand-alone and editable spreadsheet budgets based on a measurement equation including more than 40 input quantities and written to consider the effect of correlations. The program, called k0-INRIM, is presented to potential users and freely
distributed alongside the user’s manual.
The measurement equation is reported and the main features are described together with the results obtained in a validation test. An uncertainty budget compiled using the software output is given as an example
- …
