1 research outputs found
Diabetes does not impact the diagnostic performance of contrast-based fractional flow reserve: insights from the CONTRAST study
Background: Adenosine-free coronary pressure wire metrics have been proposed to test the functional significance
of coronary artery lesions, but it is unexplored whether their diagnostic performance might be altered in patients with
diabetes.
Methods: We performed a post-hoc analysis of the CONTRAST study, which prospectively enrolled an international
cohort of patients undergoing routine fractional flow reserve (FFR) assessment for standard indications. Paired,
repeated measurements of all physiology metrics (Pd/Pa, iFR, contrast-based FFR, and FFR) were made. A central core
laboratory analyzed blinded pressure tracings in a standardized fashion.
Results: Of 763 subjects enrolled at 12 international centers, 219 (29%) had diabetes. The two groups were wellbalanced
for age, clinical presentation (stable or unstable), coronary vessel studied, volume and type of intracoronary
contrast, and volume of intracoronary adenosine. A binary threshold of cFFR ≤ 0.83 produced an accuracy superior
to both Pd/Pa and iFR when compared with FFR ≤ 0.80 in the absence of significant interaction with diabetes status;
indeed, accuracy in subgroups of patients with or without diabetes was similar for cFFR (86.7 vs 85.4% respectively;
p = 0.76), iFR (84.2 vs 80.0%, p = 0.29) and Pd/Pa (81.3 vs 78.9%, p = 0.55). There was no significant heterogeneity
between patients with or without diabetes in terms of sensitivity and specificity of all metrics. The area under
the receiver operating characteristic (ROC) curve was largest for cFFR compared with Pd/Pa and iFR which were
equivalent (cFFR 0.961 and 0.928; Pd/Pa 0.916 and 0.870; iFR 0.911 and 0.861 in diabetic and non-diabetic patients
respectively).
Conclusions: cFFR provides superior diagnostic performance compared with Pd/Pa or iFR for predicting FFR irrespective
of diabetes (clinicaltrials.gov identifier NCT02184117)