    The Evaluation of a Rapid In Situ HIV Confirmation Test in a Programme with a High Failure Rate of the WHO HIV Two-Test Diagnostic Algorithm

    Get PDF
    BACKGROUND: Concerns about false-positive HIV results led to a review of testing procedures used in a Médecins Sans Frontières (MSF) HIV programme in Bukavu, eastern Democratic Republic of Congo. In addition to the WHO HIV rapid diagnostic test algorithm (RDT) (two positive RDTs alone for HIV diagnosis) used in voluntary counselling and testing (VCT) sites we evaluated in situ a practical field-based confirmation test against western blot WB. In addition, we aimed to determine the false-positive rate of the WHO two-test algorithm compared with our adapted protocol including confirmation testing, and whether weakly reactive compared with strongly reactive rapid test results were more likely to be false positives. METHODOLOGY/PRINCIPAL FINDINGS: 2864 clients presenting to MSF VCT centres in Bukavu during January to May 2006 were tested using Determine HIV-1/2 and UniGold HIV rapid tests in parallel by nurse counsellors. Plasma samples on 229 clients confirmed as double RDT positive by laboratory retesting were further tested using both WB and the Orgenics Immunocomb Combfirm HIV confirmation test (OIC-HIV). Of these, 24 samples were negative or indeterminate by WB representing a false-positive rate of the WHO two-test algorithm of 10.5% (95%CI 6.6-15.2). 17 of the 229 samples were weakly positive on rapid testing and all were negative or indeterminate by WB. The false-positive rate fell to 3.3% (95%CI 1.3-6.7) when only strong-positive rapid test results were considered. Agreement between OIC-HIV and WB was 99.1% (95%CI 96.9-99.9%) with no false OIC-HIV positives if stringent criteria for positive OIC-HIV diagnoses were used. CONCLUSIONS: The WHO HIV two-test diagnostic algorithm produced an unacceptably high level of false-positive diagnoses in our setting, especially if results were weakly positive. The most probable causes of the false-positive results were serological cross-reactivity or non-specific immune reactivity. Our findings show that the OIC-HIV confirmation test is practical and effective in field contexts. We propose that all double-positive HIV RDT samples should undergo further testing to confirm HIV seropositivity until the accuracy of the RDT testing algorithm has been established at programme level

    Application of Dried Blood Spot Specimens for Serologic Subtyping of Human Immunodeficiency Virus Type 1 in Thailand

    Full text link
    ABSTRACT Dried blood spot (DBS) specimens were assessed as an alternative to plasma for human immunodeficiency virus type 1 (HIV-1) serotyping by V3 loop peptide enzyme immunoassay. Nested PCR capable of distinguishing HIV-1 subtypes B and E was used as the reference standard. Ninety-two percent of DBS samples were typeable as either HIV-1 subtype B or E. Serotype results with DBS and plasma were identical for 254 of 257 specimens. A simple DBS collection method provides a convenient alternative for conducting HIV-1 serotype surveillance while retaining sensitivity and specificity.</jats:p

    Dried Blood Spot Sampling for Hepatitis B Virus Serology and Molecular Testing

    Get PDF
    BACKGROUND & AIMS: Dried blood spots (DBS) on filter paper have been successfully used to diagnose and monitor several infectious diseases. The aim was to investigate the performance of DBS in hepatitis B virus (HBV) diagnosis using commercial tests in comparison to standard methods. METHODS: Paired DBS and plasma samples were collected from 200 patients: 100 patients with HBsAg negative status and 100 patients with HBsAg positive status. In the latter patient, HBeAg reactivity was tested. Ten samples of anti-HBs were collected from people vaccinated against HBV. We also studied 50 patients with positive HBV DNA viral load in plasma and 10 HBV DNA negative patients. HBV genotypes and gene polymerase mutations were determined in 10 randomly selected HBV-infected patients. The DBS sample consisted of 50 µL of whole blood, i.e. a 12-mm paper card. RESULTS: The sensitivity thresholds of HBsAg and anti-HBs antibody were 0.30±0.08 IU/mL and 18.11±6.05 IU/mL, respectively, for DBS with 98% sensitivity and 100% specificity. Sensitivity was 98% and specificity 100% for the detection of HBV DNA on a blotter, considering an HBV DNA threshold of 914.1±157.8 IU/ml. Ten patients had an HBeAg positive status in plasma, all were detected positive using DBS. HBV genotyping and mutation detection were successfully performed on DBS, with full concordance between the 10 paired DBS and plasma samples. CONCLUSION: This study shows DBS is a reliable alternative to plasma specimens for quantifying and detecting HBsAg, anti-HBs, HBeAg and genotyping. DBS may increase the opportunities for HBV testing and treatment follow-up in hard-to-reach individuals
    corecore