604 research outputs found
LP 349-25: a new tight M8V binary
We present the discovery of a tight M8V binary, with a separation of only 1.2
astronomical units, obtained with the PUEO and NACO adaptive optics systems,
respectively at the CFHT and VLT telescopes. The estimated period of LP 349-25
is approximately 5 years, and this makes it an excellent candidate for a
precise mass measurement.Comment: Accepted by Astronomy and Astrophysics Letter
Preparation, structural characterisation and antibacterial properties of Ga-doped sol-gel phosphate-based glass
A sol-gel preparation of Ga-doped phosphate-based glass with potential application in antimicrobial devices has been developed. Samples of composition (CaO)(0.30)(Na2O)(0.20-x) (Ga2O3) (x) (P2O5)(0.50) where x = 0 and 0.03 were prepared, and the structure and properties of the gallium-doped sample compared with those of the sample containing no gallium. Analysis of the P-31 MAS NMR data demonstrated that addition of gallium to the sol-gel reaction increases the connectivity of the phosphate network at the expense of hydroxyl groups. This premise is supported by the results of the elemental analysis, which showed that the gallium-free sample contains significantly more hydrogen and by FTIR spectroscopy, which revealed a higher concentration of -OH groups in that sample. Ga K-edge extended X-ray absorption fine structure and X-ray absorption near-edge structure data revealed that the gallium ions are coordinated by six oxygen atoms. In agreement with the X-ray absorption data, the high-energy XRD results also suggest that the Ga3+ ions are octahedrally coordinated with respect to oxygen. Antimicrobial studies demonstrated that the sample containing Ga3+ ions had significant activity against Staphylococcus aureus compared to the control
SPHERE: the exoplanet imager for the Very Large Telescope
Observations of circumstellar environments to look for the direct signal of
exoplanets and the scattered light from disks has significant instrumental
implications. In the past 15 years, major developments in adaptive optics,
coronagraphy, optical manufacturing, wavefront sensing and data processing,
together with a consistent global system analysis have enabled a new generation
of high-contrast imagers and spectrographs on large ground-based telescopes
with much better performance. One of the most productive is the
Spectro-Polarimetic High contrast imager for Exoplanets REsearch (SPHERE)
designed and built for the ESO Very Large Telescope (VLT) in Chile. SPHERE
includes an extreme adaptive optics system, a highly stable common path
interface, several types of coronagraphs and three science instruments. Two of
them, the Integral Field Spectrograph (IFS) and the Infra-Red Dual-band Imager
and Spectrograph (IRDIS), are designed to efficiently cover the near-infrared
(NIR) range in a single observation for efficient young planet search. The
third one, ZIMPOL, is designed for visible (VIR) polarimetric observation to
look for the reflected light of exoplanets and the light scattered by debris
disks. This suite of three science instruments enables to study circumstellar
environments at unprecedented angular resolution both in the visible and the
near-infrared. In this work, we present the complete instrument and its on-sky
performance after 4 years of operations at the VLT.Comment: Final version accepted for publication in A&
Post conjunction detection of Pictoris b with VLT/SPHERE
With an orbital distance comparable to that of Saturn in the solar system,
\bpic b is the closest (semi-major axis \,9\,au) exoplanet that has
been imaged to orbit a star. Thus it offers unique opportunities for detailed
studies of its orbital, physical, and atmospheric properties, and of
disk-planet interactions. With the exception of the discovery observations in
2003 with NaCo at the Very Large Telescope (VLT), all following astrometric
measurements relative to \bpic have been obtained in the southwestern part of
the orbit, which severely limits the determination of the planet's orbital
parameters. We aimed at further constraining \bpic b orbital properties using
more data, and, in particular, data taken in the northeastern part of the
orbit.
We used SPHERE at the VLT to precisely monitor the orbital motion of beta
\bpic b since first light of the instrument in 2014. We were able to monitor
the planet until November 2016, when its angular separation became too small
(125 mas, i.e., 1.6\,au) and prevented further detection. We redetected \bpic b
on the northeast side of the disk at a separation of 139\,mas and a PA of
30 in September 2018. The planetary orbit is now well constrained.
With a semi-major axis (sma) of au (1 ), it
definitely excludes previously reported possible long orbital periods, and
excludes \bpic b as the origin of photometric variations that took place in
1981. We also refine the eccentricity and inclination of the planet. From an
instrumental point of view, these data demonstrate that it is possible to
detect, if they exist, young massive Jupiters that orbit at less than 2 au from
a star that is 20 pc away.Comment: accepted by A&
Second-generation colon capsule endoscopy compared with colonoscopy
Colon capsule endoscopy (CCE) represents a noninvasive technology
that allows visualization of the colon without requiring sedation and air
insufflation. A second-generation colon capsule endoscopy system (PillCam Colon
2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection
compared with the first-generation system. OBJECTIVE: To assess the feasibility,
accuracy, and safety of CCE-2 in a head-to-head comparison with colonoscopy.
DESIGN AND SETTING: Prospective, multicenter trial including 8 European sites.
PATIENTS: This study involved 117 patients (mean age 60 years). Data from 109
patients were analyzed. INTERVENTION: CCE-2 was prospectively compared with
conventional colonoscopy as the criterion standard for the detection of
colorectal polyps that are >/=6 mm or masses in a cohort of patients at average
or increased risk of colorectal neoplasia. Colonoscopy was independently
performed within 10 hours after capsule ingestion or on the next day. MAIN
OUTCOME MEASUREMENTS: CCE-2 sensitivity and specificity for detecting patients
with polyps >/=6 mm and >/=10 mm were assessed. Capsule-positive but
colonoscopy-negative cases were counted as false positive. Capsule excretion
rate, level of bowel preparation, and rate of adverse events also were assessed.
RESULTS: Per-patient CCE-2 sensitivity for polyps >/=6 mm and >/=10 mm was 84%
and 88%, with specificities of 64% and 95%, respectively. All 3 invasive
carcinomas were detected by CCE-2. The capsule excretion rate was 88% within 10
hours. Overall colon cleanliness for CCE-2 was adequate in 81% of patients.
LIMITATIONS: Not unblinding the CCE-2 results at colonoscopy; heterogenous
patient population; nonconsecutive patients. CONCLUSION: In this European,
multicenter study, CCE-2 appeared to have a high sensitivity for the detection of
clinically relevant polypoid lesions, and it might be considered an adequate tool
for colorectal imaging
Taux moyen et variance des séromucoïdes totaux chez la brebis normale, au cours d’un « cycle d’élevage »
Charton André, Faye P., Hervy A. Taux moyen et variance des séromucoïdes totaux chez la Brebis normale, au cours d’un «Cycle d’élevage ». In: Bulletin de l'Académie Vétérinaire de France tome 119 n°6, 1966. pp. 225-228
Identification, au microscope électronique, d'un Myxovirus isolé d’une lésion de pneumonie du veau
Berkaloff A., Faye P., Charton André. Identification, au microscope électronique, d’un Myxovirus isolé d’une lésion de pneumonie du veau. In: Bulletin de l'Académie Vétérinaire de France tome 118 n°5, 1965. pp. 201-207
Séromucoïdes : variations de taux chez l’agneau en fonction de l’âge
8 fois plus élevé que celui de l’adulte dans les heures qui suivent la naissance, le taux des séromucoïdes de l’agneau, très largement fluctuant, décroît rapidement dès les premiers jours ; il n’est plus qu’une fois et demie supérieur au taux de l’adulte à la fin de la première semaine. Il ne rejoint cependant ce dernier, en se stabilisant, que vers 4 mois
Variations dans le sérum de l'agneau du titre des anticorps inhibant l'hémagglutination par Myxovirus parainfluenzae au cours des trois premiers mois
Le titre des anticorps inhibant l’hémagglutination par Myxovi rus Parainfluenzae 3, nul chez l’agneau avant qu’il ait absorbé le colostrum maternel, s’élève dès les jours suivants et dépasse celui de la mère. Il diminue ensuite progressivement, rejoint celui de cette dernière au cours de la quatrième quinzaine et sa chute se poursuit au cours du troisième mois
Présence, dans le sérum d’Ovins, d’anticorps inhibant l’hémagglutination par Myxovirus parainfluenzae
Dans un lot composé de trente brebis et de leurs agneaux, la pro portion des sujets dont le sérum inhibe, à des titres élevés de dilu tion, l’hémagglutination des érythrocytes de cobaye par une souche bovine de Myxovirus parainfluenzae dépasse 80 p. 100. Les résultats obtenus, en inhibition d’hémagglutination et en séro neutralisation, avec la fraction globulinique du sérum précipitable par le sulfate d’ammoniaque, sont quantitativement plus faibles, mais qualita tivement analogues
- …
