830 research outputs found
A placebo-controlled, double-blind, randomized, multicenter study to assess the effects of dronedarone 400 mg twice daily for 12 weeks on atrial fibrillation burden in subjects with permanent pacemakers
Purpose Dronedarone is a benzofuran derivative with a pharmacological profile similar to amiodarone but has a more rapid onset of action and a much shorter half-life (13–19 h). Our goal was to evaluate the efficacy of dronedarone in atrial fibrillation (AF) patients using dual-chamber pacemakers capable of quantifying atrial fibrillation burden. Methods Pacemakers were adjusted to optimize AF detection. Patients with AF burden \u3e1 % were randomized to dronedarone 400 mg twice daily (BID) or placebo. Pacemakers were interrogated after 4 and 12 weeks of treatment. The primary endpoint was the change in AF burden from baseline over the 12-week treatment period. Patients with permanent AF, severe/recently decompensated heart failure, and current use of antiarrhythmic drugs were excluded. AF burden was assessed by a core laboratory blinded to treatment assignment. Results From 285 patients screened, 112 were randomized (mean age 76 years, 60 % male, 84 % hypertensive, 65 % with sick sinus syndrome, 26 % with diabetes mellitus type II, 15 % with heart failure). Baseline mean (SEM) AF burden was 8.77 % (0.16) for placebo and 10.14 % (0.17) for dronedarone. Over the 12-week study period, AF burden compared to baseline decreased by 54.4 % (0.22) (P = 0.0009) with dronedarone and trended higher by 12.8 % (0.16) (P = 0.450) with placebo. The absolute change in burden was decreased by 5.5 % in the dronedarone group and increased by 1.1 % in the placebo group. Heart rate during AF was reduced to approximately 4 beats/min with dronedarone (P = 0.285). Adverse events were higher with dronedarone compared to placebo (65 vs 56 %). Conclusions Dronedarone reduced pacemaker-assessed the relative AF burden compared to baseline and placebo by over 50 % during the 12-week observation period
Rate-equation calculations of the current flow through two-site molecular device and DNA-based junction
Here we present the calculations of incoherent current flowing through the
two-site molecular device as well as the DNA-based junction within the
rate-equation approach. Few interesting phenomena are discussed in detail.
Structural asymmetry of two-site molecule results in rectification effect,
which can be neutralized by asymmetric voltage drop at the molecule-metal
contacts due to coupling asymmetry. The results received for poly(dG)-poly(dC)
DNA molecule reveal the coupling- and temperature-independent saturation effect
of the current at high voltages, where for short chains we establish the
inverse square distance dependence. Besides, we document the shift of the
conductance peak in the direction to higher voltages due to the temperature
decrease.Comment: 12 pages, 6 figure
Current rectification by simple molecular quantum dots: an ab-initio study
We calculate a current rectification by molecules containing a conjugated
molecular group sandwiched between two saturated (insulating) molecular groups
of different length (molecular quantum dot) using an ab-initio non-equilibrium
Green's function method. In particular, we study S-(CH2)m-C10H6-(CH2)n-S
dithiol with Naphthalene as a conjugated central group. The rectification
current ratio ~35 has been observed at m = 2 and n = 10, due to resonant
tunneling through the molecular orbital (MO) closest to the electrode Fermi
level (lowest unoccupied MO in the present case). The rectification is limited
by interference of other conducting orbitals, but can be improved by e.g.
adding an electron withdrawing group to the naphthalene.Comment: 8 pages, 9 figure
Initial Independent Outcomes from Focal Impulse and Rotor Modulation Ablation for Atrial Fibrillation: Multicenter FIRM Registry
Introduction
The success of pulmonary vein isolation (PVI) for atrial fibrillation (AF) may be improved if stable AF sources identified by Focal Impulse and Rotor Mapping (FIRM) are also eliminated. The long-term results of this approach are unclear outside the centers where FIRM was developed; thus, we assessed outcomes of FIRM-guided AF ablation in the first cases at 10 experienced centers.
Methods
We prospectively enrolled n = 78 consecutive patients (61 ± 10 years) undergoing FIRM guided ablation for persistent (n = 48), longstanding persistent (n = 7), or paroxysmal (n = 23) AF. AF recordings from both atria with a 64-pole basket catheter were analyzed using a novel mapping system (Rhythm View™; Topera Inc., CA, USA). Identified rotors/focal sources were ablated, followed by PVI.
Results
Each institution recruited a median of 6 patients, each of whom showed 2.3 ± 0.9 AF rotors/focal sources in diverse locations. 25.3% of all sources were right atrial (RA), and 50.0% of patients had ≥1 RA source. Ablation of all sources required a total of 16.6 ± 11.7 minutes, followed by PVI. On >1 year follow-up with a 3-month blanking period, 1 patient lost to follow-up (median time to 1st recurrence: 245 days, IQR 145–354), single-procedure freedom from AF was 87.5% (patients without prior ablation; 35/40) and 80.5% (all patients; 62/77) and similar for persistent and paroxysmal AF (P = 0.89).
Conclusions
Elimination of patient-specific AF rotors/focal sources produced freedom-from-AF of ≈80% at 1 year at centers new to FIRM. FIRM-guided ablation has a rapid learning curve, yielding similar results to original FIRM reports in each center’s first cases
Implementation of the 2017 Berlin Concussion in Sport Group Consensus Statement in contact and collision sports: a joint position statement from 11 national and international sports organisations.
The 2017 Berlin Concussion in Sport Group Consensus Statement provides a global summary of best practice in concussion prevention, diagnosis and management, underpinned by systematic reviews and expert consensus. Due to their different settings and rules, individual sports need to adapt concussion guidelines according to their specific regulatory environment. At the same time, consistent application of the Berlin Consensus Statement's themes across sporting codes is likely to facilitate superior and uniform diagnosis and management, improve concussion education and highlight collaborative research opportunities. This document summarises the approaches discussed by medical representatives from the governing bodies of 10 different contact and collision sports in Dublin, Ireland in July 2017. Those sports are: American football, Australian football, basketball, cricket, equestrian sports, football/soccer, ice hockey, rugby league, rugby union and skiing. This document had been endorsed by 11 sport governing bodies/national federations at the time of being published
The Concussion Recognition Tool 5th Edition (CRT5): Background and rationale
The Concussion Recognition Tool 5 (CRT5) is the most recent revision of the Pocket Sport Concussion Assessment Tool 2 that was initially introduced by the Concussion in Sport Group in 2005. The CRT5 is designed to assist non-medically trained individuals to recognise the signs and symptoms of possible sport-related concussion and provides guidance for removing an athlete from play/sport and to seek medical attention. This paper presents the development of the CRT5 and highlights the differences between the CRT5 and prior versions of the instrument
Low level constraints on dynamic contour path integration
Contour integration is a fundamental visual process. The constraints on integrating
discrete contour elements and the associated neural mechanisms have typically been
investigated using static contour paths. However, in our dynamic natural environment
objects and scenes vary over space and time. With the aim of investigating the
parameters affecting spatiotemporal contour path integration, we measured human
contrast detection performance of a briefly presented foveal target embedded in
dynamic collinear stimulus sequences (comprising five short 'predictor' bars appearing
consecutively towards the fovea, followed by the 'target' bar) in four experiments. The
data showed that participants' target detection performance was relatively unchanged
when individual contour elements were separated by up to 2° spatial gap or 200ms
temporal gap. Randomising the luminance contrast or colour of the predictors, on the
other hand, had similar detrimental effect on grouping dynamic contour path and
subsequent target detection performance. Randomising the orientation of the
predictors reduced target detection performance greater than introducing misalignment
relative to the contour path. The results suggest that the visual system integrates
dynamic path elements to bias target detection even when the continuity of path is
disrupted in terms of spatial (2°), temporal (200ms), colour (over 10 colours) and
luminance (-25% to 25%) information. We discuss how the findings can be largely
reconciled within the functioning of V1 horizontal connections
- …
