905 research outputs found

    East Siberian Arctic Region Expedition '92: The Laptev Sea - Its Significance for Arctic Sea-Ice Formation and Transpolar Sediment Flux

    Get PDF
    Darin enthalten: Expedition to Novaja Zemlja and Franz Josef Land with RV "Dalnie Zelentsy" / by D. Nürnberg and E. Groth, pp. 45-7

    Customized television: Standards compliant advanced digital television

    Get PDF
    This correspondence describes a European Union supported collaborative project called CustomTV based on the premise that future TV sets will provide all sorts of multimedia information and interactivity, as well as manage all such services according to each user’s or group of user’s preferences/profiles. We have demonstrated the potential of recent standards (MPEG-4 and MPEG-7) to implement such a scenario by building the following services: an advanced EPG, Weather Forecasting, and Stock Exchange/Flight Information

    Ultralong Copper Phthalocyanine Nanowires with New Crystal Structure and Broad Optical Absorption

    Full text link
    The development of molecular nanostructures plays a major role in emerging organic electronic applications, as it leads to improved performance and is compatible with our increasing need for miniaturisation. In particular, nanowires have been obtained from solution or vapour phase and have displayed high conductivity, or large interfacial areas in solar cells. In all cases however, the crystal structure remains as in films or bulk, and the exploitation of wires requires extensive post-growth manipulation as their orientations are random. Here we report copper phthalocyanine (CuPc) nanowires with diameters of 10-100 nm, high directionality and unprecedented aspect ratios. We demonstrate that they adopt a new crystal phase, designated eta-CuPc, where the molecules stack along the long axis. The resulting high electronic overlap along the centimetre length stacks achieved in our wires mediates antiferromagnetic couplings and broadens the optical absorption spectrum. The ability to fabricate ultralong, flexible metal phthalocyanine nanowires opens new possibilities for applications of these simple molecules

    Beta reduction constraints

    Get PDF
    The constraint language for lambda structures (CLLS) can model lambda terms that are known only partially. In this paper, we introduce beta reduction constraints to describe beta reduction steps between partially known lambda terms. We show that beta reduction constraints can be expressed in an extension of CLLS by group parallelism. We then extend a known semi-decision procedure for CLLS to also deal with group parallelism and thus with beta-reduction constraints

    Diffraction effects in the Recoil-Frame Photoelectron Angular Distributions of Halomethanes

    Get PDF
    Citation: Bomme, C., Anielski, D., Savelyev, E., Boll, R., Erk, B., Bari, S., . . . Rolles, D. (2015). Diffraction effects in the Recoil-Frame Photoelectron Angular Distributions of Halomethanes. 635(11). doi:10.1088/1742-6596/635/11/112020We have measured the Recoil Frame-Photoelectron Angular Distributions (RF-PADs) for inner-shell photoionization of CH3F, CH3I and CF3I halomethane molecules for photoelectron energies up to 300 eV detected within a 4? solid angle in the gas-phase. For high kinetic energies, the RF-PADs are dominated by diffraction effects that encode information on the molecular geometry. © Published under licence by IOP Publishing Ltd

    Imaging Molecular Structure through Femtosecond Photoelectron Diffraction on Aligned and Oriented Gas-Phase Molecules

    Get PDF
    This paper gives an account of our progress towards performing femtosecond time-resolved photoelectron diffraction on gas-phase molecules in a pump-probe setup combining optical lasers and an X-ray Free-Electron Laser. We present results of two experiments aimed at measuring photoelectron angular distributions of laser-aligned 1-ethynyl-4-fluorobenzene (C8H5F) and dissociating, laseraligned 1,4-dibromobenzene (C6H4Br2) molecules and discuss them in the larger context of photoelectron diffraction on gas-phase molecules. We also show how the strong nanosecond laser pulse used for adiabatically laser-aligning the molecules influences the measured electron and ion spectra and angular distributions, and discuss how this may affect the outcome of future time-resolved photoelectron diffraction experiments.Comment: 24 pages, 10 figures, Faraday Discussions 17

    Communication: X-ray coherent diffractive imaging by immersion in nanodroplets

    Get PDF
    Citation: Tanyag, R. M. P., Bernando, C., Jones, C. F., Bacellar, C., Ferguson, K. R., Anielski, D., . . . Vilesov, A. F. (2015). Communication: X-ray coherent diffractive imaging by immersion in nanodroplets. Structural Dynamics, 2(5), 9. doi:10.1063/1.4933297Lensless x-ray microscopy requires the recovery of the phase of the radiation scattered from a specimen. Here, we demonstrate a de novo phase retrieval technique by encapsulating an object in a superfluid helium nanodroplet, which provides both a physical support and an approximate scattering phase for the iterative image reconstruction. The technique is robust, fast-converging, and yields the complex density of the immersed object. Images of xenon clusters embedded in superfluid helium droplets reveal transient configurations of quantum vortices in this fragile system. (C) 2015 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.Additional Authors: Neumark, D. M.;Rolles, D.;Rudek, B.;Rudenko, A.;Siefermann, K. R.;Ullrich, J.;Weise, F.;Bostedt, C.;Gessner, O.;Vilesov, A. F

    Hetero-site-specific X-ray pump-probe spectroscopy for femtosecond intramolecular dynamics

    Get PDF
    Citation: Picon, A., Lehmann, C. S., Bostedt, C., Rudenko, A., Marinelli, A., Osipov, T., . . . Southworth, S. H. (2016). Hetero-site-specific X-ray pump-probe spectroscopy for femtosecond intramolecular dynamics. Nature Communications, 7, 6. doi:10.1038/ncomms11652New capabilities at X-ray free-electron laser facilities allow the generation of two-colour femtosecond X-ray pulses, opening the possibility of performing ultrafast studies of X-ray-induced phenomena. Particularly, the experimental realization of hetero-site-specific X-ray-pump/X-ray-probe spectroscopy is of special interest, in which an X-ray pump pulse is absorbed at one site within a molecule and an X-ray probe pulse follows the X-ray-induced dynamics at another site within the same molecule. Here we show experimental evidence of a hetero-site pump-probe signal. By using two-colour 10-fs X-ray pulses, we are able to observe the femtosecond time dependence for the formation of F ions during the fragmentation of XeF2 molecules following X-ray absorption at the Xe site

    Point of care coagulometry in prehospital emergency care: an observational study

    Get PDF
    Background: Haemostatic impairment can have a crucial impact on the outcome of emergency patients, especially in cases of concomitant antithrombotic drug treatment. In this prospective observational study we used a point of care (POC) coagulometer in a prehospital physician-based emergency medical system in order to test its validity and potential value in the treatment of emergency patients. Methods: During a study period of 12 months, patients could be included if venous access was mandatory for further treatment. The POC device CoaguChek® was used to assess international normalized ratio (INR) after ambulance arrival at the scene. Results were compared with in-hospital central laboratory assessment of INR. The gain of time was analysed as well as the potential value of POC testing through a questionnaire completed by the responsible prehospital emergency physician. Results: A total of 103 patients were included in this study. POC INR results were highly correlated with results of conventional assessment of INR (Bland-Altman-bias: 0.014). Using a cutoff value of INR >1.3, the device’s sensitivity to detect coagulopathy was 100 % with a specificity of 98.7 %. The median gain of time was 69 min. Treating emergency physicians considered the value of prehospital POC INR testing ‘high’ in 9 % and ‘medium’ in 21 % of all patients. In patients with tracer diagnosis ‘neurology’, the value of prehospital INR assessment was considered ‘high’ or ‘medium’ (63 %) significantly more often than in patients with non-neurological tracer diagnoses (24 %). Conclusions: Assessment of INR through a POC coagulometer is feasible in prehospital emergency care and provides valuable information on haemostatic parameters in patients. Questionnaire results suggest that POC INR testing may present a valuable technique in selected patients. Whether this information translates into an improved management of respective patients has to be evaluated in further studies
    corecore