7,447 research outputs found

    Inhomogeneous critical current in nanowire superconducting single-photon detectors

    Get PDF
    A superconducting thin film with uniform properties is the key to realize nanowire superconducting single-photon detectors (SSPDs) with high performance and high yield. To investigate the uniformity of NbN films, we introduce and characterize simple detectors consisting of short nanowires with length ranging from 100nm to 15{\mu}m. Our nanowires, contrary to meander SSPDs, allow probing the homogeneity of NbN at the nanoscale. Experimental results, endorsed by a microscopic model, show the strongly inhomogeneous nature of NbN films on the sub-100nm scale.Comment: 10 pages, 4 figure

    A novel ultrafast-low-dose computed tomography protocol allows concomitant coronary artery evaluation and lung cancer screening

    Get PDF
    BACKGROUND:Cardiac computed tomography (CT) is often performed in patients who are at high risk for lung cancer in whom screening is currently recommended. We tested diagnostic ability and radiation exposure of a novel ultra-low-dose CT protocol that allows concomitant coronary artery evaluation and lung screening. METHODS: We studied 30 current or former heavy smoker subjects with suspected or known coronary artery disease who underwent CT assessment of both coronary arteries and thoracic area (Revolution CT, General Electric). A new ultrafast-low-dose single protocol was used for ECG-gated helical acquisition of the heart and the whole chest. A single IV iodine bolus (70-90 ml) was used. All patients with CT evidence of coronary stenosis underwent also invasive coronary angiography. RESULTS: All the coronary segments were assessable in 28/30 (93%) patients. Only 8 coronary segments were not assessable in 2 patients due to motion artefacts (assessability: 98%; 477/485 segments). In the assessable segments, 20/21 significant stenoses (> 70% reduction of vessel diameter) were correctly diagnosed. Pulmonary nodules were detected in 5 patients, thus requiring to schedule follow-up surveillance CT thorax. Effective dose was 1.3 ± 0.9 mSv (range: 0.8-3.2 mSv). Noteworthy, no contrast or radiation dose increment was required with the new protocol as compared to conventional coronary CT protocol. CONCLUSIONS:The novel ultrafast-low-dose CT protocol allows lung cancer screening at time of coronary artery evaluation. The new approach might enhance the cost-effectiveness of coronary CT in heavy smokers with suspected or known coronary artery disease

    Common features between neoplastic and preneoplastic lesions of the biliary tract and the pancreas

    Get PDF
    The bile duct system and pancreas show many similarities due to their anatomical proximity and common embryological origin. Consequently, preneoplastic and neoplastic lesions of the bile duct and pancreas share analogies in terms of molecular, histological and pathophysiological features. Intraepithelial neoplasms are reported in biliary tract, as biliary intraepithelial neoplasm (BilIN), and in pancreas, as pancreatic intraepithelial neoplasm (PanIN). Both can evolve to invasive carcinomas, respectively cholangiocarcinoma (CCA) and pancreatic ductal adenocarcinoma (PDAC). Intraductal papillary neoplasms arise in biliary tract and pancreas. Intraductal papillary neoplasm of the biliary tract (IPNB) share common histologic and phenotypic features such as pancreatobiliary, gastric, intestinal and oncocytic types, and biological behavior with the pancreatic counterpart, the intraductal papillary mucinous neoplasm of the pancreas (IPMN). All these neoplastic lesions exhibit similar immunohistochemical phenotypes, suggesting a common carcinogenic process. Indeed, CCA and PDAC display similar clinic-pathological features as growth pattern, poor response to conventional chemotherapy and radiotherapy and, as a consequence, an unfavorable prognosis. The objective of this review is to discuss similarities and differences between the neoplastic lesions of the pancreas and biliary tract with potential implications on a common origin from similar stem/progenitor cells

    Pulse wave velocity differs between ulcerative colitis and chronic kidney disease

    Get PDF
    Background: We hypothesized that a reversal of the physiological stiffness gradient, previously reported in end-stage renal disease, begins in the early stages of chronic kidney disease (CKD) and that chronic inflammation produces a different arterial phenotype in patients with ulcerative colitis (UC). Objectives: To assess the extent of arterial stiffening in the central (carotid-femoral pulse wave velocity, cf.-PWV) and peripheral arteries (carotid-radial pulse wave velocity, cr-PWV) and to explore the determinants of the stiffness gradient in UC and in CKD. Methods: We enrolled 45 patients with UC, 45 patients with stage 3-4 CKD and 45 matched controls. Results: Despite the comparable cf.-PWV, the cr-PWV was higher in patients with UC than in those with CKD (median: 8.7 vs. 7.5. m/s; p <. 0.001) and, consequently, the PWV ratio was lower (median: 0.97 vs. 1.12; p <. 0.001). In patients with CKD a stiffness mismatch was reported starting from stage 3B. The PWV ratio was associated with age and C-reactive protein (beta: 0.08 z-score, 95%CI 0.02-0.14; p = 0.01) or active disease (beta: 0.43 z-score, 95%CI 0.003-0.857; p = 0.048) in patients with UC and with age and glomerular filtration rate (beta: -0.56 z-score, 95%CI -1.05 to -0.07; p = 0.02) in patients with CKD. Conclusions: The arterial phenotype differed between UC and CKD. The reversal of the arterial stiffness gradient is evident in CKD patients starting from stage 3B but not in patients with UC and comparable cf.-PWV. In patients with UC, the stiffness of both elastic and muscular arteries is increased as a consequence of inflammation

    GNAM and OHP: Monitoring Tools for ATLAS experiment at LHC.

    Get PDF
    ATLAS is one of the four experiments under construction along the Large Hadron Collider (LHC) ring at CERN. The LHC will produce interactions at a center-of-mass energy equal to âs = 14 TeV at 40 MHz rate. The detector consists of more than 140 million electronic channels. The challenging experimental environment and the extreme detector complexity impose the necessity of a common scalable distributed monitoring framework, which can be tuned for the optimal use by different ATLAS sub-detectors at the various levels of the ATLAS data flow. This note presents two monitoring tools that have been developed for this aim within the architecture ATLAS Monitoring Framework and the Data Acquisition System: GNAM and OHP. The first one is a framework for online histogram production; the second one is graphical application for histogram presentation. This tools are now widely used during the ATLAS commissioning and their performances are reported in this not

    Safety analysis in large volume vacuum systems like tokamak: Experiments and numerical simulation to analyze vacuum ruptures consequences

    Get PDF
    The large volume vacuum systems are used in many industrial operations and research laboratories. Accidents in these systems should have a relevant economical and safety impact. A loss of vacuum accident (LOVA) due to a failure of the main vacuum vessel can result in a fast pressurization of the vessel and consequent mobilization dispersion of hazardous internal material through the braches. It is clear that the influence of flow fields, consequence of accidents like LOVA, on dust resuspension is a key safety issue. In order to develop this analysis an experimental facility is been developed: STARDUST. This last facility has been used to improve the knowledge about LOVA to replicate a condition more similar to appropriate operative condition like to kamaks. By the experimental data the boundary conditions have been extrapolated to give the proper input for the 2D thermofluid-dynamics numerical simulations, developed by the commercial CFD numerical code. The benchmark of numerical simulation results with the experimental ones has been used to validate and tune the 2D thermofluid-dynamics numerical model that has been developed by the authors to replicate the LOVA conditions inside STARDUST. In present work, the facility, materials, numerical model, and relevant results will be presented. © 2014 A. Malizia et al
    corecore