178 research outputs found

    Recertification guidelines for Massachusetts educators

    Get PDF
    The incorporation of the extracellular matrix (ECM) is essential for generating in vitro models that truly represent the microarchitecture found in human tissues. However, the cell-cell and cell-ECM interactions in vitro remains poorly understood in placental trophoblast biology. We investigated the effects of varying the surface properties (surface thickness and stiffness) of two ECMs, collagen I and Matrigel, on placental trophoblast cell morphology, viability, proliferation, and expression of markers involved in differentiation/syncytial fusion. Most notably, thicker Matrigel surfaces were found to induce the self-assembly of trophoblast cells into 3D spheroids that exhibited thickness-dependent changes in viability, proliferation, syncytial fusion, and gene expression profiles compared to two-dimensional cultures. Changes in F-actin organization, cell spread morphologies, and integrin and matrix metalloproteinase gene expression profiles, further reveal that the response to surface thickness may be mediated in part through cellular stiffness-sensing mechanisms. Our derivation of self-assembling trophoblast spheroid cultures through regulation of ECM surface alone contributes to a deeper understanding of cell-ECM interactions, and may be important for the advancement of in vitro platforms for research or diagnostics

    Improved inverter performance and renewable charging stations with battery swapping technique for electric vehicles

    Get PDF
    Automobiles have become a global common denominator. The hindrance with using automobile is that most of them operate with the help of fossil fuels. Exploitation of natural resources is increasing due to the demand for personal automobiles. This will cause a severe and potentially cataclysmic problem to our planet. To create a change in the global human behavior towards a more sustainable future we need to make intelligent choices for the next generation electric drive technology. By integrating Li – ion battery with solid state batteries we can achieve an efficient source with fast charging ability. A new charging station which is completely renewable will be erected for charging vehicles. With DC charging, more power can be delivered to the battery. Battery Management System (BMS) can be used to limit the peak voltage during charging and prevents cell voltage from dropping below threshold during discharging. In this we have proposed 7 level cascaded h bridge multilevel inverter topology to obtain nearly sinusoidal waveform to improve the performance and efficiency of induction motor fed electric vehicle drive system

    C. elegans MANF Homolog Is Necessary for the Protection of Dopaminergic Neurons and ER Unfolded Protein Response

    Get PDF
    Neurotrophic factors (NTFs) are important for the development, function, and survival of neurons in the mammalian system. Mesencephalic astrocyte-derived neurotrophic factor (MANF) and cerebral dopamine neurotrophic factor (CDNF) are two recently identified members of a novel family of NTFs in vertebrates that function to protect dopaminergic neurons. Although these genes are conserved across eukaryotes, their mechanism of neuroprotection is not fully understood. Sequence searches for MANF/CDNF homologs in invertebrates have identified a single ortholog that is most related to MANF. Here we report the in vivo characterization of the MANF gene, manf-1, in the nematode Caenorhabditis elegans. We found that manf-1 mutants have an accelerated, age-dependent decline in the survival of dopaminergic neurons. The animals also show increased endoplasmic reticulum (ER) stress, as revealed by reporter gene expression analysis of hsp-4, an ER chaperone BiP/GRP78 homolog, suggesting that a failure to regulate the ER unfolded protein response (ER-UPR) may be a contributing factor to dopaminergic neurodegeneration. Expression studies of manf-1 revealed that the gene is broadly expressed in a pattern that matches closely with hsp-4. Consistent with the requirements of manf-1 in the ER-UPR, we found that aggregates of α-Synuclein, a major constituent of Lewy bodies, were significantly increased in body wall muscles of manf-1 mutant animals. Overall, our work demonstrates the important role of manf-1 in dopaminergic neuronal survival and the maintenance of ER homeostasis in C. elegans

    Finite-Element Modelling of Biotransistors

    Get PDF
    Current research efforts in biosensor design attempt to integrate biochemical assays with semiconductor substrates and microfluidic assemblies to realize fully integrated lab-on-chip devices. The DNA biotransistor (BioFET) is an example of such a device. The process of chemical modification of the FET and attachment of linker and probe molecules is a statistical process that can result in variations in the sensed signal between different BioFET cells in an array. In order to quantify these and other variations and assess their importance in the design, complete physical simulation of the device is necessary. Here, we perform a mean-field finite-element modelling of a short channel, two-dimensional BioFET device. We compare the results of this model with one-dimensional calculation results to show important differences, illustrating the importance of the molecular structure, placement and conformation of DNA in determining the output signal

    Microfabricated Reference Electrodes and their Biosensing Applications

    Get PDF
    Over the past two decades, there has been an increasing trend towards miniaturization of both biological and chemical sensors and their integration with miniaturized sample pre-processing and analysis systems. These miniaturized lab-on-chip devices have several functional advantages including low cost, their ability to analyze smaller samples, faster analysis time, suitability for automation, and increased reliability and repeatability. Electrical based sensing methods that transduce biological or chemical signals into the electrical domain are a dominant part of the lab-on-chip devices. A vital part of any electrochemical sensing system is the reference electrode, which is a probe that is capable of measuring the potential on the solution side of an electrochemical interface. Research on miniaturization of this crucial component and analysis of the parameters that affect its performance, stability and lifetime, is sparse. In this paper, we present the basic electrochemistry and thermodynamics of these reference electrodes and illustrate the uses of reference electrodes in electrochemical and biological measurements. Different electrochemical systems that are used as reference electrodes will be presented, and an overview of some contemporary advances in electrode miniaturization and their performance will be provided

    Micromachined glass apertures for artificial lipid bilayer formation in a microfluidic system

    Get PDF
    The use of spark assisted chemical engraving (SACE) to produce glass apertures that are suitable for the formation of artificial bilayer lipid membranes is described. Prior to use, the glass apertures were rendered hydrophobic by a silanization process and were then incorporated into a simple microfluidic device. Successful bilayer lipid membrane (BLM) formation and the subsequent acquisition of single-channel recordings are demonstrated. Due to the simplicity and rapidity of the SACE process, these glass apertures could be easily integrated into an all-glass microfluidic system for BLM formation
    corecore