7 research outputs found

    A Diffractive Study of Parametric Process in Nonlinear Photonic Crystals

    Full text link
    We report a general description of quasi-phase-matched parametric process in nonlinear photonic crystals (NLPC) by extending the conventional X-ray diffraction theory in solids. Under the virtual wave approximation, phase-matching resonance is equivalent to the diffraction of the scattered virtual wave. Hence a modified NLPC Ewald construction can be built up, which illustrates the nature of the accident for the diffraction of the virtual wave in NLPC and further reveals the complete set of diffractions of the virtual wave for both of the air-dielectric and dielectric-dielectric contacts. We show the two basic linear sequences, the anti-stacking and para-stacking linear sequences, in one-dimension (1D) NLPC and present a general rule for multiple phase-matching resonances in 1D NLPC. The parameters affecting the NLPC structure factor are investigated, which indicate that not only the Ewald construction but also the relative NLPC atom size together determine whether a diffraction of the virtual wave can occur in 2D NLPC. The results also show that 1D NLPC is a better choice than 2D NLPC for a single parametric process

    A neutron activation analyzer

    No full text
    Dubbed "Analyzer" because of its simplicity, a neutron activation analysis facility for short-lived isomeric transitions is based on a low-cost rabbit system and an adaptive digital filter which are controlled by a software performing irradiation control, loss fre gamma-spectrometry, spectra evaluation, nuclide identification and calculation of concentrations in a fully automatic flow of operations. Designed for TRIGA reactors and constructed from inexpensive plastic tubing and an aluminium in-core part, the rabbit system features samples of 5 ml and 10 ml with sample separation at 150 ms and 200 ms transport time of 25 ml samples without separation at a transport time of 300 ms. By automatically adapting shaping times to pulse intervals the preloaded digital filter gives best throughput at best resolution up to input counting rates of 10⁶ cps. Loss-free counting enables quantitative correction of counting losses of up to 99%. As a test of system reproducibility in sample separation geometry, K, Cl, Mn, Mg, Ca, Sc, and V have been determined in various reference materials at excellent agreement with consensus values

    Nonlinear Interactions of Light and Matter with Absorption

    No full text

    Lasers

    No full text
    corecore