1,958 research outputs found

    Measuring and explaining mortality in Dutch hospitals; The Hospital Standardized Mortality Rate between 2003 and 2005

    Get PDF
    Background. Indicators of hospital quality, such as hospital standardized mortality ratios (HSMR), have been used increasingly to assess and improve hospital quality. Our aim has been to describe and explain variation in new HSMRs for the Netherlands. Methods. HSMRs were estimated using data from the complete population of discharged patients during 2003 to 2005. We used binary logistic regression to indirectly standardize for differences in case-mix. Out of a total of 101 hospitals 89 hospitals remained in our explanatory analysis. In this analysis we explored the association between HSMRs and determinants that can and cannot be influenced by hospitals. For this analysis we used a two-level hierarchical linear regression model to explain variation in yearly HSMRs. Results. The average HSMR decreased yearly with more than eight

    Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at √ s = 8 TeV with the ATLAS detector

    Get PDF
    Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb−1 of √ s = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between Emiss T > 150 GeV and Emiss T > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presente

    Neutrophils in cancer: neutral no more

    Get PDF
    Neutrophils are indispensable antagonists of microbial infection and facilitators of wound healing. In the cancer setting, a newfound appreciation for neutrophils has come into view. The traditionally held belief that neutrophils are inert bystanders is being challenged by the recent literature. Emerging evidence indicates that tumours manipulate neutrophils, sometimes early in their differentiation process, to create diverse phenotypic and functional polarization states able to alter tumour behaviour. In this Review, we discuss the involvement of neutrophils in cancer initiation and progression, and their potential as clinical biomarkers and therapeutic targets

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Feasibility of Tomotherapy-Based Image-Guided Radiotherapy to Reduce Aspiration Risk in Patients with Non-Laryngeal and Non-Pharyngeal Head and Neck Cancer

    Get PDF
    PURPOSE: The study aims to assess the feasibility of Tomotherapy-based image-guided radiotherapy (IGRT) to reduce the aspiration risk in patients with non-laryngeal and non-hypopharyngeal cancer. A retrospective review of 48 patients undergoing radiation for non-laryngeal and non-hypopharyngeal head and neck cancers was conducted. All patients had a modified barium swallow (MBS) prior to treatment, which was repeated one month following radiotherapy. Mean middle and inferior pharyngeal dose was recorded and correlated with the MBS results to determine aspiration risk. RESULTS: Mean pharyngeal dose was 23.2 Gy for the whole group. Two patients (4.2%) developed trace aspiration following radiotherapy which resolved with swallowing therapy. At a median follow-up of 19 months (1-48 months), all patients were able to resume normal oral feeding without aspiration. CONCLUSION AND CLINICAL RELEVANCE: IGRT may reduce the aspiration risk by decreasing the mean pharyngeal dose in the presence of large cervical lymph nodes. Further prospective studies with IGRT should be performed in patients with non-laryngeal and non-hypopharyngeal head and neck cancers to verify this hypothesis

    Comparative Study of Superabsorbent Polymers and Pre‐soaked Pumice as Internal Curing Agents in Rice Husk Ash Based High‐Performance Concrete

    Get PDF
    Utilisation of superabsorbent polymers (SAP) and pre‐soaked lightweight aggregates (LWA) as internal curing (IC) agents for the mitigation of autogenous shrinkage and micro‐cracking of high strength/highperformance concrete (HSC/HPC) have been well researched and documented in literature. Rice husk ash (RHA) on the other hand has been adjudged to be of good pozzolanic activity and a possible alternative to silica fume (SF) in low water/binder (W/B) concrete production. An experimental comparative study was conducted in the current work to assess the effectiveness of the two known ICagents on rice husk ash (RHA) based HPC. HPC mixtures of fc,cube28=60 MPa minimum target strength produced and internally cured with 0.3% content of SAP by weight of binder (bwob) and varied content of pre‐soaked pumice (5 to 10% in steps of 2.5%) by weight of coarse aggregate (bwocg) were cast using 100 mm cubes samples. Thereafter, the samples were cured for 7, 14, 28 and 56 days by water immersion before subjecting them to compressive strength test. The results showed 0.2% bwob SAP HPC (SHPC1) to be the best performed internally cured HPC at the early ages with similar long‐term strength values as 5 and 7.5% bwocg saturated pumiced HPC (PHPC1&2). The study thereby recommends SAP content of 0.2% bwob and saturated pumice content up to 7.5% bwocg for use as ICagent in HPC

    Search for new physics in the multijet and missing transverse momentum final state in proton-proton collisions at √s=8 Tev

    Get PDF
    Peer reviewe

    Measurement of the inelastic proton-proton cross section at √s=13 TeV with the ATLAS detector at the LHC

    Get PDF
    This Letter presents a measurement of the inelastic proton-proton cross section using 60  μb −1 of pp collisions at a center-of-mass energy √s of 13 TeV with the ATLAS detector at the LHC. Inelastic interactions are selected using rings of plastic scintillators in the forward region (2.0710 −6 , where M X is the larger invariant mass of the two hadronic systems separated by the largest rapidity gap in the event. In this ξ range the scintillators are highly efficient. For diffractive events this corresponds to cases where at least one proton dissociates to a system with M X >13  GeV . The measured cross section is compared with a range of theoretical predictions. When extrapolated to the full phase space, a cross section of 78.1±2.9  mb is measured, consistent with the inelastic cross section increasing with center-of-mass energy
    corecore