Reliability and reproducibility of perfusion MRI in cognitively normal subjects
Arterial spin labeling (ASL) magnetic resonance imaging (MRI) is becoming a popular method for measuring perfusion due to its ability of generating perfusion maps noninvasively. This allows for frequent repeat scanning, which is especially useful for follow-up studies. However, limited information is available regarding the reliability and reproducibility of ASL perfusion measurements. Here, the reliability and reproducibility of pulsed ASL was investigated in an elderly population to determine the variation in perfusion among cognitively normal individuals in different brain structures. Intraclass correlation coefficients (ICC) and within-subject variation coefficients (wsCV) were used to estimate reliability and reproducibility over a period of 1 year. Twelve cognitively normal subjects (75.5±5.3 years old, six male and six female) were scanned four times (at 0, 3, 6 and 12 months). No significant difference in cerebral blood flow (CBF) was found over this period. CBF values ranged from 46 to 53 ml/100 g per minute in the medial frontal gyrus (MFG) and from 40 to 44 ml/100 g per minute over all gray matter regions in the superior part of the brain. Data obtained from the first two scans were processed by two readers and showed high reliability (ICC >0.97) and reproducibility (wsCV <6%). However, over the total period of 1 year, reliability reduced to a moderate level (ICC=0.63-0.74) with wsCVs of gray matter, left MFG, right MFG of 13.5%, 12.3%, and 15.4%, respectively. In conclusion, measurement of CBF with pulsed ASL provided good agreement between inter-raters. A moderate level of reliability was obtained over a 1-year period, which was attributed to variance in slice positioning and coregistration. As such pulsed ASL has the potential to be used for CBF comparison in longitudinal studies. © 2010 Elsevier Inc.postprin
Quantification of thermal ring flexibilities of aromatic and heteroaromatic compounds
The consequences of thermal fluctuations occurring at room temperatures on the aromatic character of a broad group of compounds were analyzed in three distinct ways. First of all, the ring deformations were modeled along normal coordinates coming from quantum thermo-chemistry computations. The amplitudes of vibrations were estimated according to absorbed energies at room temperature. Alternatively, in-plane and out-of-plane ring deformations were modeled via scanning procedure with partial relaxation of the molecular geometry. The influence of ring deformations on π–electron delocalization was expressed in terms of HOMA values. Besides, the ring deformability was defined as the averaged change of bond angles or dihedral angles constituting the ring that was associated with 1.5 kcal mol-1 increase of the system energy. The molecules structures adopted during vibrations at room temperature can lead to significant heterogeneity of structural index of aromaticity. The broad span of HOMA values was obtained for analyzed five- or six-membered aromatic and heteroaromatic rings. However, the averaged values obtained for such fluctuations almost perfectly match HOMA values of molecule in the ground state. It has been demonstrated that the ring deformability imposed by bond angle changes is much smaller than for dihedral angles with the same rise of system energy. Interestingly in the case of out-of-plane vibrations modeled by scanning procedure there is observed linear correlation between ring deformability and HOMA values. Proposed method for inclusion of thermal vibrations in the framework of π–electron delocalization provides natural shift of the way of thinking about aromaticity from a static quantity to a dynamic and heterogeneous one due to inclusion of a more realistic object of analysis – thermally deformed structures. From this perspective the thermal fluctuations are supposed to be non-negligible contributions to aromaticity phenomenon
Quantifying brain development in the HEALthy Brain and Child Development (HBCD) Study: The magnetic resonance imaging and spectroscopy protocol.
The HEALthy Brain and Child Development (HBCD) Study, a multi-site prospective longitudinal cohort study, will examine human brain, cognitive, behavioral, social, and emotional development beginning prenatally and planned through early childhood. The acquisition of multimodal magnetic resonance-based brain development data is central to the study's core protocol. However, application of Magnetic Resonance Imaging (MRI) methods in this population is complicated by technical challenges and difficulties of imaging in early life. Overcoming these challenges requires an innovative and harmonized approach, combining age-appropriate acquisition protocols together with specialized pediatric neuroimaging strategies. The HBCD MRI Working Group aimed to establish a core acquisition protocol for all 27 HBCD Study recruitment sites to measure brain structure, function, microstructure, and metabolites. Acquisition parameters of individual modalities have been matched across MRI scanner platforms for harmonized acquisitions and state-of-the-art technologies are employed to enable faster and motion-robust imaging. Here, we provide an overview of the HBCD MRI protocol, including decisions of individual modalities and preliminary data. The result will be an unparalleled resource for examining early neurodevelopment which enables the larger scientific community to assess normative trajectories from birth through childhood and to examine the genetic, biological, and environmental factors that help shape the developing brain
What scans we will read: imaging instrumentation trends in clinical oncology
Oncological diseases account for a significant portion of the burden on public healthcare systems with associated
costs driven primarily by complex and long-lasting therapies. Through the visualization of patient-specific
morphology and functional-molecular pathways, cancerous tissue can be detected and characterized non-
invasively, so as to provide referring oncologists with essential information to support therapy management
decisions. Following the onset of stand-alone anatomical and functional imaging, we witness a push towards
integrating molecular image information through various methods, including anato-metabolic imaging (e.g., PET/
CT), advanced MRI, optical or ultrasound imaging.
This perspective paper highlights a number of key technological and methodological advances in imaging
instrumentation related to anatomical, functional, molecular medicine and hybrid imaging, that is understood as
the hardware-based combination of complementary anatomical and molecular imaging. These include novel
detector technologies for ionizing radiation used in CT and nuclear medicine imaging, and novel system
developments in MRI and optical as well as opto-acoustic imaging. We will also highlight new data processing
methods for improved non-invasive tissue characterization. Following a general introduction to the role of imaging
in oncology patient management we introduce imaging methods with well-defined clinical applications and
potential for clinical translation. For each modality, we report first on the status quo and point to perceived
technological and methodological advances in a subsequent status go section. Considering the breadth and
dynamics of these developments, this perspective ends with a critical reflection on where the authors, with the
majority of them being imaging experts with a background in physics and engineering, believe imaging methods
will be in a few years from now.
Overall, methodological and technological medical imaging advances are geared towards increased image contrast,
the derivation of reproducible quantitative parameters, an increase in volume sensitivity and a reduction in overall
examination time. To ensure full translation to the clinic, this progress in technologies and instrumentation is
complemented by progress in relevant acquisition and image-processing protocols and improved data analysis. To
this end, we should accept diagnostic images as “data”, and – through the wider adoption of advanced analysis,
including machine learning approaches and a “big data” concept – move to the next stage of non-invasive tumor
phenotyping. The scans we will be reading in 10 years from now will likely be composed of highly diverse multi-
dimensional data from multiple sources, which mandate the use of advanced and interactive visualization and
analysis platforms powered by Artificial Intelligence (AI) for real-time data handling by cross-specialty clinical experts
with a domain knowledge that will need to go beyond that of plain imaging
Diffusion nuclear magnetic resonance imaging in experimental stroke. Correlation with cerebral metabolites.
Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments
Chemical exchange saturation transfer (CEST) is a contrast mechanism that exploits exchange-based magnetization transfer (MT) between solute and water protons. CEST effects compete with direct water saturation and conventional MT processes, and generally can only be quantified through an asymmetry analysis of the water saturation spectrum (Z-spectrum) with respect to the water frequency, a process that is exquisitely sensitive to magnetic field inhomogeneities. Here it is shown that direct water saturation imaging allows measurement of the absolute water frequency in each voxel, allowing proper centering of Z-spectra on a voxel-by-voxel basis independently of spatial B0 field variations. Optimal acquisition parameters for this "water saturation shift referencing" (WASSR) approach were estimated using Monte Carlo simulations and later confirmed experimentally. The optimal ratio of the WASSR sweep width to the linewidth of the direct saturation curve was found to be 3.3- 4.0, requiring a sampling of 16-32 points. The frequency error was smaller than 1 Hz at signal-to-noise ratios of 40 or higher. The WASSR method was applied to study glycogen, where the chemical shift difference between the hydroxyl (OH) protons and bulk water protons at 3T is so small (0.75-1.25 ppm) that the CEST spectrum is inconclusive without proper referencing. © 2009 Wiley-Liss, Inc.link_to_OA_fulltex
Measurement of tissue oxygen extraction ratios from venous blood T₂: increased precision and validation of principle
- …