Cryogenic light detectors with enhanced performance for rare events physics
We have developed and tested a new way of coupling bolometric light detectors
to scintillating crystal bolometers based upon simply resting the light
detector on the crystal surface, held in position only by gravity. This
straightforward mounting results in three important improvements: (1) it
decreases the amount of non-active materials needed to assemble the detector,
(2) it substantially increases the light collection efficiency by minimizing
the light losses induced by the mounting structure, and (3) it enhances the
thermal signal induced in the light detector thanks to the extremely weak
thermal link to the thermal bath. We tested this new technique with a 16 cm
Ge light detector with thermistor readout sitting on the surface of a large
TeO bolometer. The light collection efficiency was increased by greater
than 50\% compared to previously tested alternative mountings. We obtained a
baseline energy resolution on the light detector of 20~eV RMS that, together
with increased light collection, enabled us to obtain the best vs
discrimination ever obtained with massive TeO crystals. At
the same time we achieved rise and decay times of 0.8 and 1.6 ms, respectively.
This superb performance meets all of the requirements for the CUPID (CUORE
Upgrade with Particle IDentification) experiment, which is a 1-ton
scintillating bolometer follow up to CUORE.Comment: 6 pages, 4 figure
Spatial and temporal characterization of a Bessel beam produced using a conical mirror
We experimentally analyze a Bessel beam produced with a conical mirror,
paying particular attention to its superluminal and diffraction-free
properties. We spatially characterized the beam in the radial and on-axis
dimensions, and verified that the central peak does not spread over a
propagation distance of 73 cm. In addition, we measured the superluminal phase
and group velocities of the beam in free space. Both spatial and temporal
measurements show good agreement with the theoretical predictions.Comment: 5 pages, 6 figure
Characterization of the Hamamatsu R11265-103-M64 multi-anode photomultiplier tube
The aim of this paper is to fully characterize the new multi-anode
photomultiplier tube R11265-103-M64, produced by Hamamatsu. Its high effective
active area (77%), its pixel size, the low dark signal rate and the capability
to detect single photon signals make this tube suitable for an application in
high energy physics, such as for RICH detectors. Four tubes and two different
bias voltage dividers have been tested. The results of a standard
characterization of the gain and the anode uniformity, the dark signal rate,
the cross-talk and the device behaviour as a function of temperature have been
studied. The behaviour of the tube is studied in a longitudinal magnetic field
up to 100 Gauss. Shields made of a high permeability material are also
investigated. The deterioration of the device performance due to long time
operation at intense light exposure is studied. A quantitative analysis of the
variation of the gain and the dark signals rate due to the aging is described.Comment: 22 page
A bolometric measurement of the antineutrino mass
High statistics calorimetric measurements of the beta spectrum of 187Re are
being performed with arrays of silver perrhenate crystals operated at low
temperature. After a modification of the experimental set-up, which allowed to
substantially reduce the background of spurious counts and therefore to
increase the sensitivity on the electron antineutrino mass, a new measurement
with 10 silver perrhenate microbolometers is running since July 2002. The
crystals have masses between 250 and 350 micrograms and their average FWHM
energy resolution, constantly monitored by means of fluorescence X-rays, is of
28.3 eV at the beta end-point. The Kurie plot collected during 4485 hours x mg
effective running time has an end-point energy of 2466.1 +/- 0.8{stat} +/- 1.5
{syst} eV, while the half lifetime of the decay is found to be 43.2 +/-
0.2{stat} +/- 0.1{syst} Gy. These values are the most precise obtained so far
for 187Re. From the fit of the Kurie plot we can deduce a value for the squared
electron antineutrino mass m(nu)^2 of 147 +/- 237{stat} +/- 90{syst} eV^2. The
corresponding 90% C.L. upper limit for m(nu) is 21.7 eV.Comment: 3 pages, 3 figures. Submitted to Phys. Rev. Let
- …