420 research outputs found

    Does improved functional performance help to reduce urinary incontinence in institutionalized older women? a multicenter randomized clinical trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Urinary incontinence (UI) is a major problem in older women. Management is usually restricted to dealing with the consequences instead of treating underlying causes such as bladder dysfunction or reduced mobility.</p> <p>The aim of this multicenter randomized controlled trial was to compare a group-based behavioral exercise program to prevent or reduce UI, with usual care. The exercise program aimed to improve functional performance of pelvic floor muscle (PFM), bladder and physical performance of women living in homes for the elderly.</p> <p>Methods</p> <p>Twenty participating Dutch homes were matched and randomized into intervention or control homes using a random number generator. Homes recruited 6–10 older women, with or without UI, with sufficient cognitive and physical function to participate in the program comprising behavioral aspects of continence and physical exercises to improve PFM, bladder and physical performance. The program consisted of a weekly group training session and homework exercises and ran for 6 months during which time the control group participants received care as usual. Primary outcome measures after 6 months were presence or absence of UI, frequency of episodes (measured by participants and caregivers (not blinded) using a 3-day bladder diary) and the Physical Performance Test (blinded). Linear and logistic regression analysis based on the Intention to Treat (ITT) principle using an imputed data set and per protocol analysis including all participants who completed the study and intervention (minimal attendance of 14 sessions).</p> <p>Results</p> <p>102 participants were allocated to the program and 90 to care as usual. ITT analysis (n = 85 intervention, n = 70 control) showed improvement of physical performance (intervention +8%; control −7%) and no differences on other primary and secondary outcome measures. Per protocol analysis (n = 51 intervention, n = 60 control) showed a reduction of participants with UI (intervention −40%; control −28%) and in frequency of episodes (intervention −51%; control −42%) in both groups; improvement of physical performance (intervention + 13%; control −4%) was related to participation in the exercise program.</p> <p>Conclusions</p> <p>This study shows that improving physical performance is feasible in institutionalized older women by exercise. Observed reductions in UI were not related to the intervention. [Current Controlled Trials ISRCTN63368283]</p

    Are Chronic Pain Fellowships Disguised as Acute Pain Fellowships Which Manage Chronic Pain? How to Recognize and Repair

    Get PDF
    Sayed E Wahezi,1 Ugur Yener,1 Miles Day,2 Peter S Staats,3 Christopher Gilligan,4 Michael E Schatman,5,6 Scott G Pritzlaff7 1Department of Physical Medicine and Rehabilitation, Multidisciplinary Pain Center, Montefiore Medical Center, Bronx, NY, USA; 2Department of Anesthesiology, Texas Tech University Health Sciences Center, Lubbock, TX, USA; 3National Spine and Pain Centers, Atlantic Beach, FL, USA; 4Chief Medical and Quality Officer, Senior Vice President, Robert Wood Johnson University Hospital, New Brunswick, NJ, USA; 5Department of Anesthesiology, Perioperative Care and Pain Medicine, NYU Grossman School of Medicine, New York, NY, USA; 6Department of Population Health – Division of Medical Ethics, NYU Grossman School of Medicine, New York, NY, USA; 7Department of Anesthesiology and Pain Medicine, University of California, Davis, CA, USACorrespondence: Sayed E Wahezi, Professor of Physical Medicine and Rehabilitation, Department of Physical Medicine and Rehabilitation, Montefiore Medical Center, 1250 Waters Place, Tower &num;2, 8th Floor, Bronx, NY, 10461, USA, Tel +1 718 920 7246, Fax +1 929 263 3950, Email [email protected]

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    Cranio-spinal migration of a metallic clip placed during arteriovenous malformation resection - A case report, review of the literature, and management strategies

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Microclip placement during AVM resection is generally accepted to be a safe practice in neurosurgery. Here, we describe an unusual complication involving cranio-spinal clip migration discovered five years after the initial AVM surgery.</p> <p>Case Presentation</p> <p>A 53-year-old man underwent resection of a superior vermian AVM that required the placement of two microclips during the procedure. Five years after surgery, the patient suffered from descending sensory radiculopathy that resolved spontaneously. The workup revealed cranio-spinal migration of one of the previously placed microclips.</p> <p>Conclusions</p> <p>AVM clip migration is a rare phenomenon; however, the diagnosis should be entertained in patients with posterior fossa instrumentation who suffer from unusual neurologic symptoms.</p

    Identification and recovery of ATLAS18 strip sensors with high surface static charge

    Get PDF
    The new all-silicon Inner Tracker (ITk) is being constructed by the ATLAS collaboration to track charged particles produced at the High-Luminosity LHC. The outer portion of the ITk detector will include nearly 18,000 highly segmented and radiation hard silicon strip sensors (ATLAS18 design). Throughout the production of 22,000 sensors, the strip sensors are subjected to a comprehensive suite of mechanical and electrical tests as part of the Quality Control (QC) program. In a large fraction of the batches delivered to date, high surface electrostatic charge has been measured on both the sensors and the plastic sheets between which the sensors are packaged for shipping and handling rigidity. Aggregate data from across QC sites indicate a correlation between observed electrical failures and the sensor/plastic sheet charge build up. To mitigate these issues, the QC testing sites introduced recovery techniques involving UV light or flows of ionizing gas. Significant modifications to sensor handling procedures were made to prevent subsequent build up of static charge. This publication details a precise description of the issue, a variety of sensor recovery techniques, and trend analyses of sensors initially failing electrical tests (IV, strip scan, etc.)

    Current Developments in Intraspinal Agents for Cancer and Noncancer Pain

    Get PDF
    Since the late 1980s, intrathecal (IT) analgesic therapy has improved, and implantable IT drug delivery devices have become increasingly sophisticated. Physicians and patients now have myriad more options for agents and their combination, as well as for refining their delivery. As recently as 2007, The Polyanalgesic Consensus Conference of expert panelists updated its algorithm for drug selection in IT polyanalgesia. We review this algorithm and the emerging therapy included. This article provides an update on newly approved as well as emerging IT agents and the advances in technology for their delivery

    Measurements of differential cross-sections in top-quark pair events with a high transverse momentum top quark and limits on beyond the Standard Model contributions to top-quark pair production with the ATLAS detector at √s = 13 TeV

    Get PDF
    Cross-section measurements of top-quark pair production where the hadronically decaying top quark has transverse momentum greater than 355 GeV and the other top quark decays into ℓνb are presented using 139 fb−1 of data collected by the ATLAS experiment during proton-proton collisions at the LHC. The fiducial cross-section at s = 13 TeV is measured to be σ = 1.267 ± 0.005 ± 0.053 pb, where the uncertainties reflect the limited number of data events and the systematic uncertainties, giving a total uncertainty of 4.2%. The cross-section is measured differentially as a function of variables characterising the tt¯ system and additional radiation in the events. The results are compared with various Monte Carlo generators, including comparisons where the generators are reweighted to match a parton-level calculation at next-to-next-to-leading order. The reweighting improves the agreement between data and theory. The measured distribution of the top-quark transverse momentum is used to search for new physics in the context of the effective field theory framework. No significant deviation from the Standard Model is observed and limits are set on the Wilson coefficients of the dimension-six operators OtG and Otq(8), where the limits on the latter are the most stringent to date. [Figure not available: see fulltext.]

    Improving topological cluster reconstruction using calorimeter cell timing in ATLAS

    Get PDF
    Clusters of topologically connected calorimeter cells around cells with large absolute signal-to-noise ratio (topo-clusters) are the basis for calorimeter signal reconstruction in the ATLAS experiment. Topological cell clustering has proven performant in LHC Runs 1 and 2. It is, however, susceptible to out-of-time pile-up of signals from soft collisions outside the 25 ns proton-bunch-crossing window associated with the event’s hard collision. To reduce this effect, a calorimeter-cell timing criterion was added to the signal-to-noise ratio requirement in the clustering algorithm. Multiple versions of this criterion were tested by reconstructing hadronic signals in simulated events and Run 2 ATLAS data. The preferred version is found to reduce the out-of-time pile-up jet multiplicity by ∼50% for jet pT ∼ 20 GeV and by ∼80% for jet pT 50 GeV, while not disrupting the reconstruction of hadronic signals of interest, and improving the jet energy resolution by up to 5% for 20 < pT < 30 GeV. Pile-up is also suppressed for other physics objects based on topo-clusters (electrons, photons, τ -leptons), reducing the overall event size on disk by about 6% in early Run 3 pileup conditions. Offline reconstruction for Run 3 includes the timing requirement
    corecore