154 research outputs found
Design and fabrication of double corrugated waveguide for a Ka-band traveling wave tube
The double corrugated waveguide is demonstrated to be a slow wave structure which is straightforward to manufacture and assemble. The design and fabrication of a Ka-band prototype is presented. The ability of the double corrugated waveguide to be bent through 90o has permitted the build of a compact slow wave structure with very good electrical behavior which is suitable for millimeter wave travelling wave tubes
Detection of 2.2-3.5 Terahertz Radiation Using a Quasi-Optically Mounted Planar Schottky Diode
Practical supra-terahertz (1–5 THz) heterodyne radiometry systems require compact local oscillator and mixer components, which are suitable for robust waveguide integration. We demonstrate detection of radiation emitted by quantum cascade lasers at frequencies between 2.2 and 3.5 THz using room-temperature quasi-optically mounted planar Schottky diodes. These diodes are more readily integrated into waveguides than point-contact diodes, do not require the cryogenic environment of hot-electron bolometers and offer potentially better noise performance than superlattice devices
Korrosjon i inntaksrørene for brannvann på St. Olavs Hospital - undersøkelse, omfang og årsak
For rørsystemer i stål er tiltetning og lekkasjer forårsaket av korrosjon et av hovedproblemene for vedlikehold og drift av vannbaserte brannvernsystemer. Reparasjon av korrosjonsskader på grunn av mekanisk svikt gir betydelig økning i livssykluskostnadene til et brannvernsystem. St. Olavs Hospital benytter rørsystemer i karbonstål (P235TR1), der noen komponenter er skiftet til rustfritt stål AISI 304/AISI 316. Systemet inneholder ubehandlet ferskvann tatt fra det kommunale nettverket i Trondheim, og er stillestående inntil det oppstår brann. Ved en inspeksjon høsten 2017 ble det oppdaget alvorlige korrosjonsangrep innvendig i rørene, med store mengder korrosjonsprodukt og rustknoller på overflaten. Hensikten med rapporten har vært å fastslå hovedårsaken til korrosjonsskadene oppdaget i rørsystemet på St. Olavs Hospital, med spesielt fokus på mikrobiell indusert korrosjon (MIC). Det har også blitt undersøkt muligheten for å dokumentere innvendig status i røret med ultralyd testing, og mulige tiltak for å hindre tilsvarende problem i fremtiden.
Metoder brukt til å identifisere årsaken til korrosjonsskadene er elektrokjemiske korrosjonsforsøk, hvor vann fra sykehuset ble sammenlignet med vann fra springen (med og uten oksygen). Kjemisk sammensetning i korrosjonsproduktet ble undersøkt med Energy Dispersive Spectroscopy (EDS). Vann som har vært stillestående i systemet over lengre tid ble analysert for bakterieinnhold og kjemiske parametre, og sammenlignet med vann fra det kommunale nettverket i Trondheim. Det ble også gjennomført mikrobiell samfunnsanalyse (MCA) av korrosjonsproduktet for å bestemme totalt antall bakterier og ulike typer bakterier tilstede i systemet. Ultralyd testing ble gjennomført på karbonstålrør fra 1902-bygget og Kunnskapssenteret og sammenlignet med innvendig status.
Basert på resultatetene fra det eksperimentelle arbeidet antas det at MIC er hovedårsaken til korrosjonsproblemene i rørsystemet på St. Olavs Hospital. Ultralyd testing kan gi en indikasjon på redusert veggtykkelse som følge av lokaliserte korrosjonsangrep under voluminøse tuberkler og avleiringer inne i rørene. Deteksjon av volum korrosjonsprodukt og helhetlig bilde av innvendig status er på en annen side ikke mulig. Mengden avleiringer og korrosjonsskader innvendig gjør at utskifting av rør er nødvendig. For å hindre samme problemstilling i fremtiden bør Corrosion Management strategier implementeres sammen med molekylære mikrobiologiske metoder (MMM) for å få bedre forståelse av biologiske faktorer som dominerer i biofilmer og korrosjon, sammenlignet med operasjonsforhold og miljø i brannvernsystemet. Rensing av vannet ved mikrofiltrering kan bidra til å fjerne bakterier og næringsstoffer før det entrer brannvernsystemet
Active Millimeter-Wave Radiometry for Nondestructive Testing/Evaluation of Composites--Glass Fiber Reinforced Polymer
Manufacture and in-service assessment of composite materials can be challenging since there is, yet, no standard method for testing them. Nevertheless, regular inspection is necessary to maintain the structural integrity. This paper describes a nondestructive, broadband noise mapping method that uses a millimeter-wave radiometer to detect defects in composite materials. The W-band system is configured for transmission mode measurement in which an amplified photonic source illuminates a glass fiber reinforced polymer containing machined defects. A high sensitivity radiometer is used for imaging the sample. The radiometer consists of a Schottky diode-based frequency tripler and a fundamental mixer
Active Millimeter-Wave Radiometry for Nondestructive Testing/Evaluation of Composites—Glass Fiber Reinforced Polymer
Low-Pass FSS for 50-230 GHz Quasi-Optical Demultiplexing for the MetOp Second-Generation Microwave Sounder Instrument
This paper reports the design, manufacture and characterisation of a new frequency selective surface (FSS) structure which meets the demanding requirements for transmission of 50.2 − 57.7 GHz radiation simultaneously for TE and TM polarizations at 45° incidence, and reflection of signals in four discrete higher frequency bands centered at 89 GHz, 165.5 GHz, 183.3 GHz and 229 GHz. The FSS is required for a quasi-optical network, which was developed during preparatory breadboarding of the Microwave Sounder instrument. The 100 mm diameter ultra-wide band FSS must exhibit ≤0.25 dB loss for all signals in the above bands, and has to satisfy the requirements of the space environment. The FSS is formed by a periodic metal film array sandwiched between two 0.83 mm thick, optically flat, fused quartz substrates. It has 19,000 unit cells composed of two compact resonant slot elements, a meandering elliptical annulus and a folded dipole. Spectral transmission and reflection measurements in the 50 − 230 GHz frequency range yielded results that are in excellent agreement with numerical predictions
A placebo-controlled trial of itopride in functional dyspepsia
Dyspepsia remains a common and costly problem in primary care and gastroenterology practice; in most patients who are examined, no structural lesions causing these symptoms are found.1 Dyspepsia in the absence of a clinically identifiable structural lesion is referred to as functional dyspepsia,2,3 in part because disturbed gastrointestinal function is believed to play a role in the development of symptoms.4 Pharmacologic treatments for patients with functional dyspepsia remain unsatisfactory.5 The results of controlled trials have generally been disappointing, and only small benefits relative to placebo have been found with histamine H 2 -receptor antagonists,6 proton-pump inhibitors,7 and Helicobacter pylori eradication.8 Although several randomized, controlled trials and metaanalyses have demonstrated the superiority of cisapride over placebo,9-11 the use of cisapride is now restricted in most countries because of cardiac side effects. In Japan, itopride, which is a dopamine D2 antagonist with acetylcholinesterase inhibitory actions, is often prescribed for patients with functional dyspepsia. Although this drug has been shown to stimulate gastric motility,12 large, properly designed, randomized, controlled trials in patients with functional dyspepsia are lacking. In Japan, administration of 50 mg three times daily is standard practice. However, little is known regarding the dose response in other populations. For this reason, we aimed to study the efficacy of itopride in patients with functional dyspepsia in terms of symptom improvement and to compare various doses of itopride in terms of efficacy and safety in a white population. Methods Study Design and Patient Population Patients Outpatients who were considered to have functional dyspepsia on the basis of the Rome II criteria3 were eligible for the trial. Functional dyspepsia was diagnosed if persistent or recurrent upper abdominal pain or discomfort was present. Discomfort was characterized by the presence of one or more symptoms that included early satiety, postprandial fullness, bloating, and nausea
- …
