2,351 research outputs found

    Critical fluctuations in the spin-orbit Mott insulator Sr3_3Ir2_2O7_7

    Full text link
    X-ray magnetic critical scattering measurements and specific heat measurements were performed on the perovskite iridate Sr3_3Ir2_2O7_7. We find that the magnetic interactions close to the N\'{e}el temperature TNT_N = 283.4(2) K are three-dimensional. This contrasts with previous studies which suggest two-dimensional behaviour like Sr2_2IrO4_4. Violation of the Harris criterion (dν>2d\nu>2) means that weak disorder becomes relevant. This leads a rounding of the antiferromagnetic phase transition at TNT_N, and modifies the critical exponents relative to the clean system. Specifically, we determine that the critical behaviour of Sr3_3Ir2_2O7_7 is representative of the diluted 3D Ising universality class.Comment: Accepted in Journal of Physics: Condensed Matte

    A weakly correlated Fermi liquid state with a small Fermi surface in lightly doped Sr3_3Ir2_2O7_7

    Get PDF
    We characterize the electron doping evolution of (Sr1x_{1-x}Lax_x)3_3Ir2_2O7_7 by means of angle-resolved photoemission. Concomitant with the metal insulator transition around x0.05x\approx0.05 we find the emergence of coherent quasiparticle states forming a closed small Fermi surface of volume 3x/23x/2, where xx is the independently measured La concentration. The quasiparticle weight ZZ remains large along the entire Fermi surface, consistent with the moderate renormalization of the low-energy dispersion. This indicates a conventional, weakly correlated Fermi liquid state with a momentum independent residue Z0.5Z\approx0.5 in lightly doped Sr3_3Ir2_2O$_7&.Comment: 5 pages, 4 figure

    Anisotropic exchange and spin-wave damping in pure and electron-doped Sr2_2IrO4_4

    Get PDF
    The collective magnetic excitations in the spin-orbit Mott insulator (Sr1x_{1-x}Lax_x)2_2IrO4_4 (x=0,0.01,0.04,0.1x=0,\,0.01,\,0.04,\, 0.1) were investigated by means of resonant inelastic x-ray scattering. We report significant magnon energy gaps at both the crystallographic and antiferromagnetic zone centers at all doping levels, along with a remarkably pronounced momentum-dependent lifetime broadening. The spin-wave gap is accounted for by a significant anisotropy in the interactions between Jeff=1/2J_\text{eff}=1/2 isospins, thus marking the departure of Sr2_2IrO4_4 from the essentially isotropic Heisenberg model appropriate for the superconducting cuprates.Comment: 6 pages, 4 figure

    Limiting the effects of earthquakes on gravitational-wave interferometers

    Full text link
    Ground-based gravitational wave interferometers such as the Laser Interferometer Gravitational-wave Observatory (LIGO) are susceptible to high-magnitude teleseismic events, which can interrupt their operation in science mode and significantly reduce the duty cycle. It can take several hours for a detector to stabilize enough to return to its nominal state for scientific observations. The down time can be reduced if advance warning of impending shaking is received and the impact is suppressed in the isolation system with the goal of maintaining stable operation even at the expense of increased instrumental noise. Here we describe an early warning system for modern gravitational-wave observatories. The system relies on near real-time earthquake alerts provided by the U.S. Geological Survey (USGS) and the National Oceanic and Atmospheric Administration (NOAA). Hypocenter and magnitude information is generally available in 5 to 20 minutes of a significant earthquake depending on its magnitude and location. The alerts are used to estimate arrival times and ground velocities at the gravitational-wave detectors. In general, 90\% of the predictions for ground-motion amplitude are within a factor of 5 of measured values. The error in both arrival time and ground-motion prediction introduced by using preliminary, rather than final, hypocenter and magnitude information is minimal. By using a machine learning algorithm, we develop a prediction model that calculates the probability that a given earthquake will prevent a detector from taking data. Our initial results indicate that by using detector control configuration changes, we could prevent interruption of operation from 40-100 earthquake events in a 6-month time-period

    The importance of XY anisotropy in Sr2IrO4 revealed by magnetic critical scattering experiments

    Get PDF
    The magnetic critical scattering in Sr2_2IrO4_4 has been characterized using X-ray resonant magnetic scattering (XRMS) both below and above the 3D antiferromagnetic ordering temperature, TN_{\text{N}}. The order parameter critical exponent below TN_{\text{N}} is found to be \beta=0.195(4), in the range of the 2D XYh4_4 universality class. Over an extended temperature range above TN_{\text{N}}, the amplitude and correlation length of the intrinsic critical fluctuations are well described by the 2D Heisenberg model with XY anisotropy. This contrasts with an earlier study of the critical scattering over a more limited range of temperature which found agreement with the theory of the isotropic 2D Heisenberg quantum antiferromagnet, developed to describe the critical fluctuations of the conventional Mott insulator La2_2CuO4_4 and related systems. Our study therefore establishes the importance of XY anisotropy in the low-energy effective Hamiltonian of Sr2_2IrO4_4, the prototypical spin-orbit Mott insulator.Comment: 6 pages, 4 figure

    Rod-structure classification of gravitational instantons with U(1)xU(1) isometry

    Full text link
    The rod-structure formalism has played an important role in the study of black holes in D=4 and 5 dimensions with RxU(1)^{D-3} isometry. In this paper, we apply this formalism to the study of four-dimensional gravitational instantons with U(1)xU(1) isometry, which could serve as spatial backgrounds for five-dimensional black holes. We first introduce a stronger version of the rod structure with the rod directions appropriately normalised, and show how the regularity conditions can be read off from it. Requiring the absence of conical and orbifold singularities will in general impose periodicity conditions on the coordinates, and we illustrate this by considering known gravitational instantons in this class. Some previous results regarding certain gravitational instantons are clarified in the process. Finally, we show how the rod-structure formalism is able to provide a classification of gravitational instantons, and speculate on the existence of possible new gravitational instantons.Comment: 43 pages, 5 figures, LaTeX; minor changes made and reference added, published versio

    Collapse of the Mott gap and emergence of a nodal liquid in lightly doped Sr2_2IrO4_4

    Get PDF
    Superconductivity in underdoped cuprates emerges from an unusual electronic state characterised by nodal quasiparticles and an antinodal pseudogap. The relation between this state and superconductivity is intensely studied but remains controversial. The discrimination between competing theoretical models is hindered by a lack of electronic structure data from related doped Mott insulators. Here we report the doping evolution of the Heisenberg antiferromagnet Sr2_2IrO4_4, a close analogue to underdoped cuprates. We demonstrate that metallicity emerges from a rapid collapse of the Mott gap with doping, resulting in lens-like Fermi contours rather than disconnected Fermi arcs as observed in cuprates. Intriguingly though, the emerging electron liquid shows nodal quasiparticles with an antinodal pseudogap and thus bares strong similarities with underdoped cuprates. We conclude that anisotropic pseudogaps are a generic property of two-dimensional doped Mott insulators rather than a unique hallmark of cuprate high-temperature superconductivity

    The amateurs. A complete guide for non-professional dramatic organizations.

    Full text link
    Thesis (M.A.)--Boston University This item was digitized by the Internet Archive

    The potential role of cost-utility analysis in the decision to implement major system change in acute stroke services in metropolitan areas in England

    Get PDF
    BACKGROUND: The economic implications of major system change are an important component of the decision to implement health service reconfigurations. Little is known about how best to report the results of economic evaluations of major system change to inform decision-makers. Reconfiguration of acute stroke care in two metropolitan areas in England, namely London and Greater Manchester (GM), was used to analyse the economic implications of two different implementation strategies for major system change. METHODS: A decision analytic model was used to calculate difference-in-differences in costs and outcomes before and after the implementation of two major system change strategies in stroke care in London and GM. Values in the model were based on patient level data from Hospital Episode Statistics, linked mortality data from the Office of National Statistics and data from two national stroke audits. Results were presented as net monetary benefit (NMB) and using Programme Budgeting and Marginal Analysis (PBMA) to assess the costs and benefits of a hypothetical typical region in England with approximately 4000 strokes a year. RESULTS: In London, after 90 days, there were nine fewer deaths per 1000 patients compared to the rest of England (95% CI -24 to 6) at an additional cost of £770,027 per 1000 stroke patients admitted. There were two additional deaths (95% CI -19 to 23) in GM, with a total costs saving of £156,118 per 1000 patients compared to the rest of England. At a £30,000 willingness to pay the NMB was higher in London and GM than the rest of England over the same time period. The results of the PBMA suggest that a GM style reconfiguration could result in a total greater health benefit to a region. Implementation costs were £136 per patient in London and £75 in GM. CONCLUSIONS: The implementation of major system change in acute stroke care may result in a net health benefit to a region, even one functioning within a fixed budget. The choice of what model of stroke reconfiguration to implement may depend on the relative importance of clinical versus cost outcomes
    corecore