1,821 research outputs found
Real-Time Analysis of Student Comprehension: An Assessment of Electronic Student Response Technology in an Introductory Earth Science Course
This article describes an evualuation of the effectiveness of electronic student response technologies (SRT). These wireless systems allow students to key in responses with remote control units to questions posed by an instructor in the classroom. Student responses then are displayed in real time, allowing both students and instructors to gauge student comprehension instantaneously. Researchers conducted a multi-faceted assessment of the use of SRT in four sections of a high-enrollment introductory Earth Science course at Penn State University. The assessment included quantitative and qualitative perception data from students enrolled in the course and faculty/administrator visitors to the classroom. Preliminary assessment of the pedagogical merits of SRT in the course suggests that this technology is an effective tool for introductory geoscience education. Educational levels: Graduate or professional, Graduate or professional
Heterodimensional FET with split drain
A modification to heterodimensional field effect transistors (HDFET) is introduced and demonstrated to provide novel switching capabilities. The modification consists of introducing a split drain into the HDFET structure allowing the transistor to operate as a single pole-double throw switch. By extension, multiple pole-multiple throw switches can be made within a single transistor structure by introduction of multiple split drains or sources. If the device is fabricated on silicon germanium substrates, compatibility of the structure with conventional CMOS processing is achievable, allowing for new applications in digital, mixed signal, and high voltage switching
Slopes To Prevent Trapping of Bubbles in Microfluidic Channels
The idea of designing a microfluidic channel to slope upward along the direction of flow of the liquid in the channel has been conceived to help prevent trapping of gas bubbles in the channel. In the original application that gave rise to this idea, the microfluidic channels are parts of micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. It is necessary to prevent trapping of gas bubbles in these devices because uninterrupted liquid pathways are essential for sustaining the electrical conduction and flows that are essential for CE. The idea is also applicable to microfluidic devices that may be developed for similar terrestrial microCE biotechnological applications or other terrestrial applications in which trapping of bubbles in microfluidic channels cannot be tolerated. A typical microCE device in the original application includes, among other things, multiple layers of borosilicate float glass wafers. Microfluidic channels are formed in the wafers, typically by use of wet chemical etching. The figure presents a simplified cross section of part of such a device in which the CE channel is formed in the lowermost wafer (denoted the channel wafer) and, according to the present innovation, slopes upward into a via hole in another wafer (denoted the manifold wafer) lying immediately above the channel wafer. Another feature of the present innovation is that the via hole in the manifold wafer is made to taper to a wider opening at the top to further reduce the tendency to trap bubbles. At the time of reporting the information for this article, an effort to identify an optimum technique for forming the slope and the taper was in progress. Of the techniques considered thus far, the one considered to be most promising is precision milling by use of femtosecond laser pulses. Other similar techniques that may work equally well are precision milling using a focused ion beam, or a small diamond-tipped drill bit
Fabricating PFPE Membranes for Capillary Electrophoresis
A process has been developed for fabricating perfluoropolyether (PFPE) membranes that contain microscopic holes of precise sizes at precise locations. The membranes are to be incorporated into laboratory-on-a-chip microfluidic devices to be used in performing capillary electrophoresis. The present process is a modified version of part of the process, described in the immediately preceding article, that includes a step in which a liquid PFPE layer is cured into solid (membrane) form by use of ultraviolet light. In the present process, one exploits the fact that by masking some locations to prevent exposure to ultraviolet light, one can prevent curing of the PFPE in those locations. The uncured PFPE can be washed away from those locations in the subsequent release and cleaning steps. Thus, holes are formed in the membrane in those locations. The most straightforward way to implement the modification is to use, during the ultraviolet-curing step, an ultraviolet photomask similar to the photomasks used in fabricating microelectronic devices. In lieu of such a photomask, one could use a mask made of any patternable ultraviolet-absorbing material (for example, an ink or a photoresist)
A review of segmentation and deformable registration methods applied to adaptive cervical cancer radiation therapy treatment planning
Objective: Manual contouring and registration for radiotherapy treatment planning and online adaptation for cervical cancer radiation therapy in computed tomography (CT) and magnetic resonance images (MRI) are often necessary. However manual intervention is time consuming and may suffer from inter or intra-rater variability. In recent years a number of computer-guided automatic or semi-automatic segmentation and registration methods have been proposed. Segmentation and registration in CT and MRI for this purpose is a challenging task due to soft tissue deformation, inter-patient shape and appearance variation and anatomical changes over the course of treatment. The objective of this work is to provide a state-of-the-art review of computer-aided methods developed for adaptive treatment planning and radiation therapy planning for cervical cancer radiation therapy. Methods: Segmentation and registration methods published with the goal of cervical cancer treatment planning and adaptation have been identified from the literature (PubMed and Google Scholar). A comprehensive description of each method is provided. Similarities and differences of these methods are highlighted and the strengths and weaknesses of these methods are discussed. A discussion about choice of an appropriate method for a given modality is provided. Results: In the reviewed papers a Dice similarity coefficient of around 0.85 along with mean absolute surface distance of 2-4. mm for the clinically treated volume were reported for transfer of contours from planning day to the treatment day. Conclusions: Most segmentation and non-rigid registration methods have been primarily designed for adaptive re-planning for the transfer of contours from planning day to the treatment day. The use of shape priors significantly improved segmentation and registration accuracy compared to other models
Increased circulating T cell reactivity to GM3 and GQ1b gangliosides in primary progressive multiple sclerosis
We have previously shown that patients with primary progressive multiple sclerosis (MS) have significantly elevated plasma levels of antibody to GM3 ganglioside compared to patients with relapsing-remitting MS, healthy subjects and patients with other neurological diseases. Anti-GM3 antibody levels were elevated also in patients with secondary progressive MS but to a lesser extent than in primary progressive MS. As gangliosides are particularly enriched in the axonal membrane, these findings suggested that antiganglioside immune responses might contribute to the axonal damage in progressive forms of MS. The present study was performed to determine whether peripheral blood T cell responses to GM3 are also increased in progressive MS. Blood was collected from 98 untreated patients with MS (40 with relapsing-remitting, 27 with secondary progressive and 31 with primary progressive MS), 50 healthy subjects and 24 patients with other disorders of the CNS, and reactivity to GM1, GM3, GD1a, GD1b, GD3, GT1b, GQ1b and sulphatide was assessed by 6-day T cell proliferation assays. Increased T cell reactivity to GM3 and GQ1b occurred significantly more often in patients with primary progressive MS than in healthy subjects and patients with other CNS diseases. These findings suggest that ganglioside-specific T cells may contribute to the axonal damage in primary progressive MS. (C) 2002 Elsevier Science Ltd. All rights reserved
Gender and Videogames: The political valency of Lara Croft
The Face: Is Lara a feminist icon or a sexist fantasy? Toby Gard: Neither and a bit of both. Lara was designed to be a tough, self-reliant, intelligent woman. She confounds all the sexist cliches apart from the fact that she’s got an unbelievable figure. Strong, independent women are the perfect fantasy girls—the untouchable is always the most desirable (Interview with Lara’s creator Toby Gard in The Face magazine, June 1997)
- …
