963 research outputs found
Influence of the Leakage Current on the Performance of Large Area Silicon Drift Detectors
In this paper we investigate the influence of the leakage current on the performance of Silicon Drift Detectors. First, analytical considerations are given in order to highlight the problems, specific for this type of detector, that emerge with leakage current. Then the obtained results are compared with the data of laboratory measurements. Aiming at a mass production of SDDs for the Inner Tracking System of the ALICE experiment at LHC we propose a simple and fast measurement for a preliminary selection before passing to a detailed acceptance test
SiPM and front-end electronics development for Cherenkov light detection
The Italian Institute of Nuclear Physics (INFN) is involved in the
development of a demonstrator for a SiPM-based camera for the Cherenkov
Telescope Array (CTA) experiment, with a pixel size of 66 mm. The
camera houses about two thousands electronics channels and is both light and
compact. In this framework, a R&D program for the development of SiPMs suitable
for Cherenkov light detection (so called NUV SiPMs) is ongoing. Different
photosensors have been produced at Fondazione Bruno Kessler (FBK), with
different micro-cell dimensions and fill factors, in different geometrical
arrangements. At the same time, INFN is developing front-end electronics based
on the waveform sampling technique optimized for the new NUV SiPM. Measurements
on 11 mm, 33 mm, and 66 mm NUV SiPMs
coupled to the front-end electronics are presentedComment: In Proceedings of the 34th International Cosmic Ray Conference
(ICRC2015), The Hague, The Netherlands. All CTA contributions at
arXiv:1508.0589
Beam test results of the irradiated Silicon Drift Detector for ALICE
The Silicon Drift Detectors will equip two of the six cylindrical layers of
high precision position sensitive detectors in the ITS of the ALICE experiment
at LHC. In this paper we report the beam test results of a SDD irradiated with
1 GeV electrons. The aim of this test was to verify the radiation tolerance of
the device under an electron fluence equivalent to twice particle fluence
expected during 10 years of ALICE operation.Comment: 6 pages,6 figures, to appear in the proceedings of International
Workshop In high Multiplicity Environments (TIME'05), 3-7 October 2005,
Zurich,Switzerlan
Radiation Damage Studies of Silicon Photomultipliers
We report on the measurement of the radiation hardness of silicon
photomultipliers (SiPMs) manufactured by
Fondazione Bruno Kessler in Italy (1 mm and 6.2 mm), Center of
Perspective Technology and Apparatus in Russia (1 mm and 4.4 mm), and
Hamamatsu Corporation in Japan (1 mm). The SiPMs were irradiated using a
beam of 212 MeV protons at Massachusetts General Hospital, receiving fluences
of up to protons per cm with the SiPMs at operating
voltage. Leakage currents were read continuously during the irradiation. The
delivery of the protons was paused periodically to record scope traces in
response to calibrated light pulses to monitor the gains, photon detection
efficiencies, and dark counts of the SiPMs. The leakage current and dark noise
are found to increase with fluence. Te leakage current is found to be
proportional to the mean square deviation of the noise distribution, indicating
the dark counts are due to increased random individual pixel activation, while
SiPMs remain fully functional as photon detectors. The SiPMs are found to
anneal at room temperature with a reduction in the leakage current by a factor
of 2 in about 100 days.Comment: 35 pages, 25 figure
Psychiatric consultations in pre-orthoptic liver transplantation patients with substance use disorders: focus on timing of cessation and referral and retention by community service
Introduction: In Italy, 6 months of abstinence from alcohol/substances are required before OLT, evidence
for this recommendation remaining controversial. No standard approach linking abstinence duration at the
index psychiatric pre-OLT evaluation to referral to Community Services is followed.
Aims: To report data of the Modena Consultation-Liaison Psychiatric Service (MCLPS) for pre-OLT patients
with Substance Use Disorders (SUDs), and to evaluate patients’ concordance with referrals.
Methods: Case-control study. Data source: database of MCLPS. Psychiatric evaluations pre-OLT from
01/01/2008 to 31/12/2013 were extracted. Patients were controls if they had a SUD and abstinent for more
than 6 months; cases if they had a SUD with less than 6 months of abstinence. Chi-squared analysis was
performed with STATA 13.0.
Results: 515 consultations were requested for 309 pre-OLT patients, 36.3% (N=112) of patients had a
current or past SUD. Controls were 80 (71.3%), while cases - who had stopped use less than 6 months
before the consultation, or were still using- were 20 (17.9%). 52.5% of controls (N=42) and 85.0% of cases
(N=17) were referred to community services (Chi 5.71; p=0.02). 70.0% of cases (N=14) and 33.6% of
controls (N=27) were seen at least twice (Chi 7.22; p=0.01). 16.7% (N=2) of cases and 23.5 % (N=4) of
controls referred to community services reported concordance with Consultant’s recommendation at reassessment,
a non-significant difference with cases (Chi 0.00; p=1.00).
Conclusions: Consistently with previously research in this field, no difference of concordance with
recommendations emerged between patients with SUD with different duration of abstinence
Measurements and tests on FBK silicon sensors with an optimized electronic design for a CTA camera
In October 2013, the Italian Ministry approved the funding of a Research &
Development (R&D) study, within the "Progetto Premiale TElescopi CHErenkov made
in Italy (TECHE)", devoted to the development of a demonstrator for a camera
for the Cherenkov Telescope Array (CTA) consortium. The demonstrator consists
of a sensor plane based on the Silicon Photomultiplier (SiPM) technology and on
an electronics designed for signal sampling. Preliminary tests on a matrix of
sensors produced by the Fondazione Bruno Kessler (FBK-Trento, Italy) and on
electronic prototypes produced by SITAEL S.p.A. will be presented. In
particular, we used different designs of the electronics in order to optimize
the output signals in terms of tail cancellation. This is crucial for
applications where a high background is expected, as for the CTA experiment.Comment: 5 pages, 6 figures; Proceedings of the 10th Workshop on Science with
the New Generation of High-Energy Gamma-ray experiments (SciNeGHE) -
PoS(Scineghe2014)00
Development and tests of a new prototype detector for the XAFS beamline at Elettra Synchrotron in Trieste
The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption
spectroscopy and X-ray diffraction to provide chemically specific structural
information of materials. It operates in the energy range 2.4-27 keV by using a
silicon double reflection Bragg monochromator. The fluorescence measurement is
performed in place of the absorption spectroscopy when the sample transparency
is too low for transmission measurements or the element to study is too diluted
in the sample. We report on the development and on the preliminary tests of a
new prototype detector based on Silicon Drift Detectors technology and the
SIRIO ultra low noise front-end ASIC. The new system will be able to reduce
drastically the time needed to perform fluorescence measurements, while keeping
a short dead time and maintaining an adequate energy resolution to perform
spectroscopy. The custom-made silicon sensor and the electronics are designed
specifically for the beamline requirements.Comment: Proceeding of the 6YRM 12th-14th Oct 2015 - L'Aquila (Italy).
Accepted for publication on Journal of Physics: Conference Serie
Characteristics of the ALICE Silicon Drift Detector
A Silicon Drift Detector (SDD) with an active area of 7.0 x 7.5 cm2 has been designed, produced and tested for the ALICE Inner Tracking System. The development of the SDD has been focussed on the capability of the detector to work without an external support to the integrated high voltage divider. Severalfeatures have been implemented in the design in order to increase the robustness and the long-term electrical stability of the detector. One of the prototypes has been tested in a pion beam at the CERN SPS. Preliminary results on the position resolution are given
- …