865 research outputs found
A One-Dimensional Synthetic-Aperture Microwave Radiometer
A proposed one-dimensional synthetic- aperture microwave radiometer could serve as an alternative to either the two-dimensional synthetic-aperture radiometer described in the immediately preceding article or to a prior one-dimensional one, denoted the Electrically Scanned Thinned Array Radiometer (ESTAR), mentioned in that article. The proposed radiometer would operate in a pushbroom imaging mode, utilizing (1) interferometric cross-track scanning to obtain cross-track resolution and (2) the focusing property of a reflector for along-track resolution. The most novel aspect of the proposed system would be the antenna (see figure), which would include a cylindrical reflector of offset parabolic cross section. The reflector could be made of a lightweight, flexible material amenable to stowage and deployment. Other than a stowage/deployment mechanism, the antenna would not include moving parts, and cross-track scanning would not entail mechanical rotation of the antenna. During operation, the focal line, parallel to the cylindrical axis, would be oriented in the cross-track direction, so that placement of receiving/radiating elements at the focal line would afford the desired along-track resolution. The elements would be microwave feed horns sparsely arrayed along the focal line. The feed horns would be oriented with their short and long cross-sectional dimensions parallel and perpendicular, respectively, to the cylindrical axis to obtain fan-shaped beams having their broad and narrow cross-sectional dimensions parallel and perpendicular, respectively, to the cylindrical axis. The interference among the beams would be controlled in the same manner as in the ESTAR to obtain along-cylindrical- axis (cross-track) resolution and cross-track scanning
Design and Development of VHF Antennas for Space Borne Signal of Opportunity Receivers for Cubesat Platforms
Design and Development of VHF Antennas for Space Borne Signal of Opportunity Receivers for Cubesat Platforms. Space borne microwave remote sensors at VHF/UHF frequencies are important instruments to observe reflective properties of land surfaces through thick and heavy forestation on a global scale. One of the most cost effective ways of measuring land reflectivity at VHF/UHF frequencies is to use signals transmitted by existing communication satellites (operating at VHF/UHF band) as a signal of opportunity (SoOp) signal and passive receivers integrated with airborne/space borne platforms operating in the Low Earth Orbit (LEO). One of the critical components of the passive receiver is two antennas (one to receive only direct signal and other to receive only reflected signal) which need to have ideally high (>30dB) isolation. However, because of small size of host platforms and broad beam width of dipole antennas, achieving adequate isolation between two channels is a challenging problem and need to be solved for successful implementation of space borne SoOp technology for remote sensing. In this presentation a novel enabling VHF antenna technology for Cubesat platforms is presented to receive direct as well as reflected signal with needed isolation. The novel scheme also allows enhancing the gain of individual channels by factor of 2 without use of reflecting ground plan
Processing and initial comparison of PSR data from CAMEX-3 to SSM/I and TMI data
A multiband Polarimetric Scanning Radiometer (PSR) was integrated on a NASA DC-8 aircraft and flown from August through September of 1998 during the third Convection and Moisture Experiment (CAMEX-3). The PSR is a new conically-scanning imaging radiometer with channels at 10.7, 18.7, 21.5, 37.0 and 89.0 GHz, including both vertical and horizontal polarizations at each of these frequencies. These channels correspond to several key sensing bands of the DMSP (Defense Meteorological Satellite Program) SSM/I (Special Sensor Microwave Imager) and the NASA TRMM (Tropical Rainfall Measuring Mission) TMI (TRMM Microwave Imager). The PSR was developed by Georgia Institute of Technology and the NOAA Environmental Technology Laboratory and is the first airborne imaging radiometer to provide a research quality dataset of high spatial resolution multiband polarimetric microwave imagery within and around a hurricane. The authors describe the processing and calibration of the PSR CAMEX-3 dataset. They also provide a qualitative analysis and comparison of the PSR imagery to the SSM/I and TMI with specific regard to the spatial structure of a hurricane eyewall and surrounding rainbands.Peer ReviewedPostprint (published version
Ultralow-Power Digital Correlator for Microwave Polarimetry
A recently developed high-speed digital correlator is especially well suited for processing readings of a passive microwave polarimeter. This circuit computes the autocorrelations of, and the cross-correlations among, data in four digital input streams representing samples of in-phase (I) and quadrature (Q) components of two intermediate-frequency (IF) signals, denoted A and B, that are generated in heterodyne reception of two microwave signals. The IF signals arriving at the correlator input terminals have been digitized to three levels (-1,0,1) at a sampling rate up to 500 MHz. Two bits (representing sign and magnitude) are needed to represent the instantaneous datum in each input channel; hence, eight bits are needed to represent the four input signals during any given cycle of the sampling clock. The accumulation (integration) time for the correlation is programmable in increments of 2(exp 8) cycles of the sampling clock, up to a maximum of 2(exp 24) cycles. The basic functionality of the correlator is embodied in 16 correlation slices, each of which contains identical logic circuits and counters (see figure). The first stage of each correlation slice is a logic gate that computes one of the desired correlations (for example, the autocorrelation of the I component of A or the negative of the cross-correlation of the I component of A and the Q component of B). The sampling of the output of the logic gate output is controlled by the sampling-clock signal, and an 8-bit counter increments in every clock cycle when the logic gate generates output. The most significant bit of the 8-bit counter is sampled by a 16-bit counter with a clock signal at 2(exp 8) the frequency of the sampling clock. The 16-bit counter is incremented every time the 8-bit counter rolls over
Noise Source for Calibrating a Microwave Polarimeter
A correlated-noise source has been developed for use in calibrating an airborne or spaceborne Earth-observing correlation microwave polarimeter that operates in a in a pass band that includes a nominal frequency of 10.7 GHz. Deviations from ideal behavior of the hardware of correlation polarimeters are such as to decorrelate the signals measured by such an instrument. A correlated-noise source provides known input signals, measurements of which can be processed to estimate and correct for the decorrelation effect
Mitigation of Terrestrial Radar Interference in L-Band Spaceborne Microwave Radiometers
Terrestrial radars operating in the 1215-1400 MHz radio-location and navigation spectrum allocation are important for air traffic safety, homeland security, and national defense. For low-frequency observations of soil moisture and ocean salinity, Earth-observing microwave radiometers are allocated Earth- Exploration Satellite Service (EESS) spectrum for operating at 1400-1427 MHz. The proximity of powerful long-range radars to the passive allocation makes observing a challenge. Three aspects of mitigation to RFI are discussed in this paper: survivability, operability, and excisability (SOE). Modeling and simulations of NASA's Hydros and Aquarius radiometers were performed to examine the impacts of radar interference. The results are applied to the three aspects of mitigation SOE and the affects on the radiometer requirements are discussed
Aquarius L-Band Microwave Radiometer: Three Years of Radiometric Performance and Systematic Effects
The Aquarius L-band microwave radiometer is a three-beam pushbroom instrument designed to measure sea surface salinity. Results are analyzed for performance and systematic effects over three years of operation. The thermal control system maintains tight temperature stability promoting good gain stability. The gain spectrum exhibits expected orbital variations with 1f noise appearing at longer time periods. The on-board detection and integration scheme coupled with the calibration algorithm produce antenna temperatures with NEDT 0.16 K for 1.44-s samples. Nonlinearity is characterized before launch and the derived correction is verified with cold-sky calibration data. Finally, long-term drift is discovered in all channels with 1-K amplitude and 100-day time constant. Nonetheless, it is adeptly corrected using an exponential model
Robust Waveguide Millimeter Wave Noise Source
Aspects of the present disclosure involve a system and method for generating noise waves at millimeter wave frequencies. A noise source generator is designed to be connected to a crystalline structure for efficient heat transfer and compatibility with millimeter wave receivers. The use of crystalline structure coupled to the noise source generator allows heat from a biasing device, such as a diode, to be carried away such that the diode is able to generate noise waves while being reversed biased without compromising the device. In another embodiment, the noise source generator includes the use of a backshort transmission line with vias that is connected to the biasing device for heat transfer from the biasing device to the backshort
Wideband Digital Signal Processing Test-Bed for Radiometric RFI Mitigation
Radio Frequency Interference (RFI) is a persistent and growing problem experienced by spaceborne microwave radiometers. Recent missions such as SMOS, SMAP, and GPM has detected RFI in L, C, X, and K bands. To proactively deal with this issue, microwave radiometers must (1) Utilize new algorithms for RFI detection (2) Utilize fast digital back-ends that sample at hundreds of MHz. The wideband digital signal processing testbed (WB-RFI) is a platform that allows rapid deelopment and testing various RFI detection and mitigation algorithms
Aquarius Radiometer Performance: Early On-Orbit Calibration and Results
The Aquarius/SAC-D observatory was launched into a 657-km altitude, 6-PM ascending node, sun-synchronous polar orbit from Vandenberg, California, USA on June 10, 2011. The Aquarius instrument was commissioned two months after launch and began operating in mission mode August 25. The Aquarius radiometer meets all engineering requirements, exhibited initial calibration biases within expected error bars, and continues to operate well. A review of the instrument design, discussion of early on-orbit performance and calibration assessment, and investigation of an on-going calibration drift are summarized in this abstract
- …
