11,252 research outputs found
Conductance increases produced by bath application of cholinergic agonists to Electrophorus electroplaques
When solutions containing agonists are applied to the innervated face of an Electrophorus electroplaque, the membrane's conductance increases. The agonist-induced conductance is increased at more negative membrane potentials. The "instantaneous" current-voltage curve for agonist-induced currents is linear and shows a reversal potential near zero mV; chord conductances, calculated on the basis of this reversal potential, change epsilon-fold for every 62-mV change in potential when the conductance is small. Conductance depends non- linearly on small agonist concentrations; at all potentials, the dose-response curve has a Hill coefficient of 1.45 for decamethonium (Deca) and 1.90 for carbamylcholine (Carb). With agonist concentrations greater than 10^(-4) M Carb or 10^(-5) M Deca, the conductance rises to a peak 0.5-1.5 min after introduction of agonist, then declines with time; this effect resembles the "desensitization" reported for myoneural junctions. Elapid alpha-toxin, tubocurarine, and desensitization reduce the conductance without changing the effects of potential; the apparent dissociation constant for tubocurarine is 2 X 10^(-7) M. By contrast, procaine effects a greater fractional inhibition of the conductance at high negative potentials
Fe/Co Alloys for the Catalytic Chemical Vapor Deposition Synthesis of Single- and Double-Walled Carbon Nanotubes (CNTs). 2. The CNT−Fe/Co−MgAl2O4 System
A detailed 57Fe Mössbauer study of the Mg(0.8)Fe(0.2-y)Co(y)Al2O4 (y = 0, 0.05, 0.1, 0.15, 0.2) solid solutions and of the CNT-Fe/Co-MgAl2O4 nanocomposite powders prepared by reduction in H2-CH4 has allowed characterization of the different iron phases involved in the catalytic process of carbon nanotube (CNT) formation and to correlate these results with the carbon and CNT contents. The oxide precursors consist of defective spinels of general formulas (Mg(1-x-y)(2+)Fe(x-3alpha)(2+)Fe(2alpha)(3+)[symbol: see text](alpha)Co(y)(2+)Al2(3+))O4(2-) . The metallic phase in the CNT-Fe/Co-MgAl2O4 nanocomposite powders is mostly in the form of the ferromagnetic alpha-Fe/Co alloy with the desired composition. For high iron initial proportions, the additional formation of Fe3C and gamma-Fe-C is observed while for high cobalt initial proportions, the additional formation of a gamma-Fe/Co-C phase is favored. The higher yield of CNTs is observed for postreaction alpha-Fe(0.50)Co(0.50) catalytic particles, which form no carbide and have a narrow size distribution. Alloying is beneficial for this system with respect to the formation of CNTs
Sorting Jordan sequences in linear time
For a Jordan curve C in the plane, let x_{1},x_{2},...,x_{n} be the abscissas of the intersection points of C with the x-axis, listed in the order the points occur on C. We call x_{1},x_{2},...,x_{n} a Jordan sequence. In this paper we describe an O(n)-time algorithm for recognizing and sorting Jordan sequences. The problem of sorting such sequences arises in computational geometry and computational geography. Our algorithm is based on a reduction of the recognition and sorting problem to a list-splitting problem. To solve the list-splitting problem we use level linked search trees
Understanding Trichoderma bio-inoculants in the root ecosystem of Pinus radiata
Oral presentation on understanding Trichoderma bio-inoculants in the root ecosystem of Pinus radiat
Le paludisme urbain à Yaoundé (Cameroun) : 2. Etude entomologique dans deux quartiers peu urbanisés
International audienceA one year entomological survey was carried out to precise the malaria vectors and the malaria transmission in Yaounde, the Cameroon capital (800,000 inhabitants). The study was done in two districts not yet fully urbanized: Nkol Bikok and Nkol Bisson. The latter is located at the periphery and has a pool. Anopheles gambiae was the only human malaria vector. Its agressivity for man depended on the urbanization of the district. Annual man biting rate was 284 in Nkol Bikok and 1,813 in Nkol Bisson. The densities were maximum in May-June and in October-November, corresponding to the end of the short and long rainy seasons. The presence of A. gambiae was permanent except in August-September in Nkol Bikok. In Nkol Bisson the density was higher in the houses near the pool. The yearly inoculation rate (h) was 14 in Nkol Bikok and 30 in Nkol Bisson. The vectorial transmission was observed in may in Nkol Bikok and during four months (June, August, January, February) in Nkol Bisson. These entomological data showed clearly that malaria transmission actually occurred in Yaounde and that the probability to receive at least one infected anopheline bite per year was very near to 1 for inhabitants unprotected against mosquito bites.Une étude longitudinale basée sur la capture des moustiques sur sujets humains s'est déroulée pendant un an dans deux quartiers de la ville de Yaoundé, l'un est situé à la périphérie de la ville (Nkol Bisson) et l'autre est plus central (Nkol Bikok). Ces deux quartiers présentent encore un caractère périurbain mais ils sont en pleine urbanisation. Le vecteur du paludisme humain identifé est Anopheles gambiae. Sa densité agressive pour l'homme (ma) est variable selon le degré d'urbanisation des quartiers : forte en Zone périphérique (ma annuel = I 813) et faible en zone centrale (ma annuel = 284). Cette densité est importante de mai à juin et d'octobre 6 novembre, c'est-à-dire à la fin de la petite et de la grande saison des pluies. Le taux d'inoculation (h) varie comme les densités agressives : h annuel = 30 en zone périphérique contre 14 en zone centrale. La transmission vectorielle est notable seulement pendant un mois (mai) à Nkol Bikok et pendant quatre mois (juin, août, janvier, février) à Nkol Bisson. Le risque quotidien d'au moins une inoculation par A. gambiae est environ deux fois plus élevé en zone périphérique qu'en zone centrale
Magnetization of polar ice: a measurement of terrestrial dust and extraterrestrial fallout
Laboratory-induced remanent magnetization of polar ice constitutes a measurement of the magnetization carried by the ferromagnetic dust particles in the ice. This non-destructive technique provides a novel kind of information on the dust deposited on the surface of polar ice sheets. Measurements made on ice samples from Greenland (North GRIP ice core) and Antarctica (Vostok and EPICA-Dome C ice cores) allowed the recognition of a fraction of magnetic minerals in ice whose concentration and magnetic properties are directly related to that of insoluble dust. The source of this fraction of magnetic minerals thus appears closely related to terrestrial dust transport and deposition and its magnetic properties are informative of the dust provenance areas. The rock-magnetic properties of the dust may reflect distinct changes of dust source areas from glacial to interglacial periods in agreement with and adding further information to the isotopic (87Sr/86Sr and 143Nd/144Nd) analyses. A second magnetic fraction consists of particles of nanometric size, which are superparamagnetic at freezer temperature and whose concentration is independent of the mass of aerosol dust found in the ice. The source of these nanometric-sized magnetic particles is ascribed to fallout of “meteoric smoke” and their concentration in ice was found to be compatible with the extraterrestrial fallout inferred from Ir concentrations. The diameter of the smoke particles as inferred from magnetic measurements is in the range of about 7–20 nm
Anthropophilic mosquitoes and malaria transmission at Edea, Cameroon
International audienceAn entomological study was carried out during 1990 in the town of Edea in the south of Cameroon to study anthropophilic mosquitoes with special reference to malaria transmission. Man-biting mosquitoes were caught regularly during one night each month in two different districts: Bilalang which is a well planned suburb with 160 houses on a hill-top, provided with a piped water supply; and Pongo which is a densely urbanised suburb in a valley. From 188 man-nights 1030 mosquitoes were collected, comprising 700 Culex quinquefasciatus (68%), 262 Anopheles gambiae (25%) and others species (7%) belonging to the genus Anopheles, Mansonia, Culex and Aedes. The estimated annual biting rates of mosquitoes were 811 bites per man in Bilalang and 2,866 in Pongo. The estimated yearly malaria inoculation rates were 3.8 and 30.2 infective bites per man in Bilalang and Pongo, respectively. In different parts of Pongo district much variation existed; extreme values of the estimated yearly inoculation rate were zero and 86.3 in two houses 200 m apart, located on the top of a hill and in the bottom of a valley, respectively. This study is one of the first conducted on malaria transmission in a moderate sized African town; it shows that the mosquito populations are typically urban and differ greatly from rural ones
- …
