3,234 research outputs found
Ultra narrow AuPd and Al wires
In this letter we discuss a novel and versatile template technique aimed to
the fabrication of sub-10 nm wide wires. Using this technique, we have
successfully measured AuPd wires, 12 nm wide and as long as 20 m. Even
materials that form a strong superficial oxide, and thus not suited to be used
in combination with other techniques, can be successfully employed. In
particular we have measured Al wires, with lateral width smaller or comparable
to 10 nm, and length exceeding 10 m.Comment: 4 pages, 4 figures. Pubblished in APL 86, 172501 (2005). Added
erratum and revised Fig.
Probing High Frequency Noise with Macroscopic Resonant Tunneling
We have developed a method for extracting the high-frequency noise spectral
density of an rf-SQUID flux qubit from macroscopic resonant tunneling (MRT)
rate measurements. The extracted noise spectral density is consistent with that
of an ohmic environment up to frequencies ~ 4 GHz. We have also derived an
expression for the MRT lineshape expected for a noise spectral density
consisting of such a broadband ohmic component and an additional strongly
peaked low-frequency component. This hybrid model provides an excellent fit to
experimental data across a range of tunneling amplitudes and temperatures
Parametric coupling between macroscopic quantum resonators
Time-dependent linear coupling between macroscopic quantum resonator modes
generates both a parametric amplification also known as a {}"squeezing
operation" and a beam splitter operation, analogous to quantum optical systems.
These operations, when applied properly, can robustly generate entanglement and
squeezing for the quantum resonator modes. Here, we present such coupling
schemes between a nanomechanical resonator and a superconducting electrical
resonator using applied microwave voltages as well as between two
superconducting lumped-element electrical resonators using a r.f.
SQUID-mediated tunable coupler. By calculating the logarithmic negativity of
the partially transposed density matrix, we quantitatively study the
entanglement generated at finite temperatures. We also show that
characterization of the nanomechanical resonator state after the quantum
operations can be achieved by detecting the electrical resonator only. Thus,
one of the electrical resonator modes can act as a probe to measure the
entanglement of the coupled systems and the degree of squeezing for the other
resonator mode.Comment: 15 pages, 4 figures, submitte
Decoherence, Autler-Townes effect, and dark states in two-tone driving of a three-level superconducting system
We present a detailed theoretical analysis of a multi-level quantum system
coupled to two radiation fields and subject to decoherence. We concentrate on
an effect known from quantum optics as the Autler-Townes splitting, which has
been recently demonstrated experimentally [M. A. Sillanpaa et al., Phys. Rev.
Lett. 103, 193601 (2009)] in a superconducting phase qubit. In the three-level
approximation, we derive analytical solutions and describe how they can be used
to extract the decoherence rates and to account for the measurement data.
Better agreement with the experiment can be obtained by extending this model to
five levels. Finally, we investigate the stationary states created in the
experiment and show that their structure is close to that of dark states.Comment: 16 pages, 8 figure
Intraoperative measurement of parathyroid hormone: A Copernican revolution in the surgical treatment of hyperparathyroidism
Intraoperative parathyroid hormone (PTH) monitoring in the setting of the operating room represents a valuable example of the rationale use of the laboratory diagnostic in a patient-oriented approach. Rapid intraoperative PTH (ioPTH) assay is a valid tool for an accurate evaluation of the success of parathyroid surgery. The reliability of the user-friendly portable systems as well as the collaboration between operators and surgical staff allow the one-site monitoring of the ioPTH decrements on the course of the surgical management of hyperparathyroidism.The rapid answer provided by an effective decrement of PTH during parathyroidectomy contributes dramatically to the efficacy of parathyroid surgery and the reduction of the number of re-operations. Therefore the dose of ioPTH is a valid and reliable support for the success of the intervention of parathyroidectomy at controlled costs
- …
