5,803 research outputs found

    Radiation damage and annealing in 1310 nm InGaAsP/InP lasers for the CMS tracker

    Get PDF
    Radiation damage in 1310 nm InGaAsP/InP multi-quantum-well lasers caused by 0.8 MeV neutrons is compared with the damage from other radiation sources, in terms of the increase in laser threshold current. The annealing behavior is then presented both in terms of both temperature and forward-bias current dependence. The annealing can be described by a model where radiation induced defects have a uniform distribution of activation energies for annealing. This model can then be used to predict the long-term damage expected for lasers operating inside the CMS tracker. (19 refs)

    Pre-Production and Quality Assurance of the Mu2e Calorimeter Silicon Photomultipliers

    Full text link
    The Mu2e electromagnetic calorimeter has to provide precise information on energy, time and position for \sim100 MeV electrons. It is composed of 1348 un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers (SiPMs). A modular and custom SiPM layout consisting of a 3×\times2 array of 6×\times6 mm2^2 UV-extended monolithic SiPMs has been developed to fulfill the Mu2e calorimeter requirements and a pre-production of 150 prototypes has been procured by three international firms (Hamamatsu, SensL and Advansid). A detailed quality assurance process has been carried out on this first batch of photosensors: the breakdown voltage, the gain, the quenching time, the dark current and the Photon Detection Efficiency (PDE) have been determined for each monolithic cell of each SiPMs array. One sample for each vendor has been exposed to a neutron fluency up to \sim8.5~×\times~1011^{11} 1 MeV (Si) eq. n/cm2^{2} and a linear increase of the dark current up to tens of mA has been observed. Others 5 samples for each vendor have undergone an accelerated aging in order to verify a Mean Time To Failure (MTTF) higher than \sim106^{6} hours.Comment: NDIP 2017 - New Developments In Photodetection, 3-7 July 2017, Tours (France

    Time stability of asymmetric Fabry-Perot modulator based analog lightwave links

    Get PDF
    Lightwave links for analog signal transfer are being developed and evaluated for application in high-density interconnects. The reflective links are based on compact electro-optic intensity modulators connected by ribbons of single-mode fibres to remotely located transceivers (lasers and photoreceivers) and read-out electronics. For long-term characterization, four Asymmetric Fabry-Perot Modulator (AFPM) prototypes were continuously operated and monitored over a period of eight monthes. The collected data allow evaluation of the system time stability and simulation of the possible recalibration procedures. The recalibration requirements to achieve the desirable accuracy and reliability are inferred statistically

    Inhibition of acetylpolyamine and spermine oxidases by the polyamine analogue chlorhexidine

    Get PDF
    ""Acetylpolyamine and spermine oxidases are involved in the catabolism of polyamines. The discovery of selective. inhibitors of these enzymes represents an important tool for the development of novel anti-neoplastic drugs. Here, a. comparative study on acetylpolyamine and spermine oxidases inhibition by the polyamine analogue chlorhexidine. is reported. Chlorhexidine is an antiseptic diamide, commonly used as a bactericidal and bacteriostatic agent.. Docking simulations indicate that chlorhexidine binding to these enzymes is compatible with the stereochemical. properties of both acetylpolyamine oxidase and spermine oxidase active sites. In fact, chlorhexidine is predicted. to establish several polar and hydrophobic interactions with the active site residues of both enzymes, with binding. energy values ranging from −7.6 to −10.6 kcal\\\/mol. In agreement with this hypothesis, inhibition studies indicate that. chlorhexidine behaves as a strong competitive inhibitor of both enzymes, values of Ki being 0.10 μM and 0.55 μM for. acetylpolyamine oxidase and spermine oxidase, respectively."

    The Met80Ala and Tyr67His/Met80Ala mutants of human cytochrome cshed light on the reciprocal role of Met80 and Tyr67 in regulating ligand access into the heme pocket.

    Get PDF
    The spectroscopic and functional properties of the single Met80Ala and double Tyr67His/Met80Ala mutants of human cytochrome c have been investigated in their ferric and ferrous forms, and in the presence of different ligands, in order to clarify the reciprocal effect of these two residues in regulating the access of exogenous molecules into the heme pocket. In the ferric state, both mutants display an aquo high spin and a low spin species. The latter corresponds to an OH- ligand in Met80Ala but to a His in the double mutant. The existence of these two species is also reflected in the functional behavior of the mutants. The observation that (i) a significant peroxidase activity is present in the Met80Ala mutants, (ii) the substitution of the Tyr67 by His leads to only a slight increase of the peroxidase activity in the Tyr67His/Met80Ala double mutant with respect to wild type, while the Tyr67His mutant behaves as wild type, as previously reported, suggests that the peroxidase activity of cytochrome c is linked to an overall conformational change of the heme pocket and not only to the disappearance of the Fe-Met80 bond. Therefore, in human cytochrome c there is an interplay between the two residues at positions 67 and 80 that affects the conformation of the distal side of the heme pocket, and thus the sixth coordination of the hem

    Design, status and perspective of the Mu2e crystal calorimeter

    Full text link
    The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less μe\mu \to e coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about 2.510172.5\cdot 10^{-17} that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform μ\mu/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. In this paper we present the calorimeter design and the latest R&\&D results.Comment: 4 pages, conference proceeding for a presentation held at TIPP'2017. To be published on Springer Proceedings in Physic

    Optical links for the CMS tracker

    Get PDF
    The development phase of the optical data transfer system for the CMS tracker is nearing completion. This paper focuses on three types of validation tests carried out by CERN on Commercial-Off-The-Shelf electro-optic devices: functionality tests, environmental tests and reliability tests. The project status and the preparation for production are also reviewed. 1

    Quality Assurance on a custom SiPMs array for the Mu2e experiment

    Full text link
    The Mu2e experiment at Fermilab will search for the coherent μe\mu \to e conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.Comment: 4 pages, 10 figures, conference proceeding for NSS-MIC 201
    corecore