118 research outputs found
Comparison of spatial filter selectivity in surface myoelectric signal detection - Influence of the volume conductor model
Oxygen-Enhanced and Dynamic Contrast-Enhanced Optoacoustic Tomography Provide Surrogate Biomarkers of Tumor Vascular Function, Hypoxia, and Necrosis.
Measuring the functional status of tumor vasculature, including blood flow fluctuations and changes in oxygenation, is important in cancer staging and therapy monitoring. Current clinically approved imaging modalities suffer long procedure times and limited spatiotemporal resolution. Optoacoustic tomography (OT) is an emerging clinical imaging modality that may overcome these challenges. By acquiring data at multiple wavelengths, OT can interrogate hemoglobin concentration and oxygenation directly and resolve contributions from injected contrast agents. In this study, we tested whether two dynamic OT techniques, oxygen-enhanced (OE) and dynamic contrast-enhanced (DCE)-OT, could provide surrogate biomarkers of tumor vascular function, hypoxia, and necrosis. We found that vascular maturity led to changes in vascular function that affected tumor perfusion, modulating the DCE-OT signal. Perfusion in turn regulated oxygen availability, driving the OE-OT signal. In particular, we demonstrate for the first time a strong per-tumor and spatial correlation between imaging biomarkers derived from these in vivo techniques and tumor hypoxia quantified ex vivo Our findings indicate that OT may offer a significant advantage for localized imaging of tumor response to vascular-targeted therapies when compared with existing clinical DCE methods.Significance: Imaging biomarkers derived from optoacoustic tomography can be used as surrogate measures of tumor perfusion and hypoxia, potentially yielding rapid, multiparametric, and noninvasive cancer staging and therapeutic response monitoring in the clinic.Graphical Abstract: http://cancerres.aacrjournals.org/content/canres/78/20/5980/F1.large.jpg Cancer Res; 78(20); 5980-91. ©2018 AACR
Consensus for experimental design in electromyography (CEDE) project: High-density surface electromyography matrix
High-density surface electromyography (HDsEMG) can be used to measure the spatial distribution of electrical muscle activity over the skin. As this distribution is associated with the generation and propagation of muscle fiber action potentials, HDsEMG is processed to extract information on regional muscle activation, muscle fiber characteristics and behaviour of individual motor units. This matrix, developed by the Consensus for Experimental Design in Electromyography (CEDE) project, summarizes recommendations on the use of HDsEMG in experimental studies. For each application, recommendations are included regarding electrode montage, electrode type and configuration, electrode location and orientation, data analysis, and interpretation. Cautions and reporting standards are also included. The steps of the Delphi process to reach consensus are contained in an appendix. This matrix is intended to help researchers when collecting, reporting, and interpreting HDsEMG data. It is hoped that this document will be used to generate new empirical evidence to improve how HDsEMG is used in research and in clinical applications
Consensus for experimental design in electromyography (CEDE) project: Single motor unit matrix
The analysis of single motor unit (SMU) activity provides the foundation from which information about the neural strategies underlying the control of muscle force can be identified, due to the one-to-one association between the action potentials generated by an alpha motor neuron and those received by the innervated muscle fibers. Such a powerful assessment has been conventionally performed with invasive electrodes (i.e., intramuscular electromyography (EMG)), however, recent advances in signal processing techniques have enabled the identification of single motor unit (SMU) activity in high-density surface electromyography (HDsEMG) recordings. This matrix, developed by the Consensus for Experimental Design in Electromyography (CEDE) project, provides recommendations for the recording and analysis of SMU activity with both invasive (needle and fine-wire EMG) and non-invasive (HDsEMG) SMU identification methods, summarizing their advantages and disadvantages when used during different testing conditions. Recommendations for the analysis and reporting of discharge rate and peripheral (i.e., muscle fiber conduction velocity) SMU properties are also provided. The results of the Delphi process to reach consensus are contained in an appendix. This matrix is intended to help researchers to collect, report, and interpret SMU data in the context of both research and clinical applications
Consensus for experimental design in electromyography (CEDE) project: Application of EMG to estimate muscle force
Skeletal muscles power movement. Deriving the forces produced by individual muscles has applications across various fields including biomechanics, robotics, and rehabilitation. Since direct in vivo measurement of muscle force in humans is invasive and challenging, its estimation through non-invasive methods such as electromyography (EMG) holds considerable appeal. This matrix, developed by the Consensus for Experimental Design in Electromyography (CEDE) project, summarizes recommendations on the use of EMG to estimate muscle force. The matrix encompasses the use of bipolar surface EMG, high density surface EMG, and intra-muscular EMG (1) to identify the onset of muscle force during isometric contractions, (2) to identify the offset of muscle force during isometric contractions, (3) to identify force fluctuations during isometric contractions, (4) to estimate force during dynamic contractions, and (5) in combination with musculoskeletal models to estimate force during dynamic contractions. For each application, recommendations on the appropriateness of using EMG to estimate force and justification for each recommendation are provided. The achieved consensus makes clear that there are limited scenarios in which EMG can be used to accurately estimate muscle forces. In most cases, it remains important to consider the activation as well as the muscle state and other biomechanical and physiological factors— such as in the context of a formal mechanical model. This matrix is intended to encourage interdisciplinary discussions regarding the integration of EMG with other experimental techniques and to promote advances in the application of EMG towards developing muscle models and musculoskeletal simulations that can accurately predict muscle forces in healthy and clinical populations
Behaviour of motor unit action potential rate, estimated from surface EMG, as a measure of muscle activation level
BACKGROUND: Surface electromyography (EMG) parameters such as root-mean-square value (RMS) are commonly used to assess the muscle activation level that is imposed by the central nervous system (CNS). However, RMS is influenced not only by motor control aspects, but also by peripheral properties of the muscle and recording setup. To assess motor control separately, the number of motor unit action potentials (MUAPs) per second, or MUAP Rate (MR) is a potentially useful measure. MR is the sum of the firing rates of the contributing MUs and as such reflects the two parameters that the CNS uses for motor control: number of MUs and firing rate. MR can be estimated from multi-channel surface EMG recordings. The objective of this study was to explore the behaviour of estimated MR (eMR) in relation to number of active MUs and firing rate. Furthermore, the influence of parameters related to peripheral muscle properties and recording setup (number of fibers per MU, fiber diameter, thickness of the subcutaneous layer, signal-to-noise-ratio) on eMR was compared with their influence on RMS. METHODS: Physiological parameters were varied in a simulation model that generated multi-channel EMG signals. The behaviour of eMR in simulated conditions was compared with its behaviour in experimental conditions. Experimental data was obtained from the upper trapezius muscle during a shoulder elevation task (20–100 N). RESULTS: The simulations showed strong, monotonously increasing relations between eMR and number of active MUs and firing rate (r(2 )> 0.95). Because of unrecognized superimpositions of MUAPs, eMR was substantially lower than the actual MUAP Rate (aMR). The percentage of detected MUAPs decreased with aMR, but the relation between eMR and aMR was rather stable in all simulated conditions. In contrast to RMS, eMR was not affected by number of fibers per MU, fiber diameter and thickness of the subcutaneous layer. Experimental data showed a strong relation between eMR and force (individual second order polynomial regression: 0.96 < r(2 )< 0.99). CONCLUSION: Although the actual number of MUAPs in the signal cannot be accurately extracted with the present method, the stability of the relation between eMR and aMR and its independence of muscle properties make eMR a suitable parameter to assess the input from the CNS to the muscle at low contraction levels non-invasively
Task-Dependent Inhomogeneous Muscle Activities within the Bi-Articular Human Rectus Femoris Muscle
The motor nerve of the bi-articular rectus femoris muscle is generally split from the femoral nerve trunk into two sub-branches just before it reaches the distal and proximal regions of the muscle. In this study, we examined whether the regional difference in muscle activities exists within the human rectus femoris muscle during maximal voluntary isometric contractions of knee extension and hip flexion. Surface electromyographic signals were recorded from the distal, middle, and proximal regions. In addition, twitch responses were evoked by stimulating the femoral nerve with supramaximal intensity. The root mean square value of electromyographic amplitude during each voluntary task was normalized to the maximal compound muscle action potential amplitude (M-wave) for each region. The electromyographic amplitudes were significantly smaller during hip flexion than during knee extension task for all regions. There was no significant difference in the normalized electromyographic amplitude during knee extension among regions within the rectus femoris muscle, whereas those were significantly smaller in the distal than in the middle and proximal regions during hip flexion task. These results indicate that the bi-articular rectus femoris muscle is differentially controlled along the longitudinal direction and that in particular the distal region of the muscle cannot be fully activated during hip flexion
Quadriceps performance under activation of foot dorsal extension in healthy volunteers: an interventional cohort study
A Novel Unsupervised Segmentation Approach Quantifies Tumor Tissue Populations Using Multiparametric MRI: First Results with Histological Validation
- …