142 research outputs found

    Varus inclination of the proximal tibia or the distal femur does not influence high tibial osteotomy outcome

    Get PDF
    We have analysed retrospectively the influence of different sources of knee deformity on failure of closing wedge high tibial valgus osteotomy (HTO). Preoperative frontal plane varus deformities of the lower extremity, distal femur and proximal tibia, and medial convergence of the knee joint line were assessed on a standard whole leg radiograph in 76 patients. Using the logistic regression model, the probability of survival for HTO was 77% (SD 4%) at 10-years follow-up. Varus deformity of the lower extremity ( 3 degrees ) were identified as preoperative risk factors for conversion to arthroplasty (P = 0.03 and P = 0.006). We found no evidence that varus inclination of the proximal tibia or distal femur influences long-term survival of HTO

    Custom stems for femoral deformity in patients less than 40 years of age: 70 hips followed for an average of 14 years

    Get PDF
    Background and purpose Femoral deformity associated with osteoarthritis is a challenge for both the surgeon and the implant. Many of the patients with these deformities are young. Standard implants can be difficult to fit into these femurs. We prospectively evaluated the outcome of custom uncemented femoral stems in young patients

    Heterogeneity in clinical practices for post-cardiotomy extracorporeal life support: A pilot survey from the PELS-1 multicenter study

    Get PDF
    Background: High-quality evidence for post-cardiotomy extracorporeal life support (PC-ECLS) management is lacking. This study investigated real-world PC-ECLS clinical practices. Methods: This cross-sectional, multi-institutional, international pilot survey explored center organization, anticoagulation management, left ventricular unloading, distal limb perfusion, PC-ECLS monitoring, and transfusion practices. Twenty-nine questions were distributed among 34 hospitals participating in the Post-cardiotomy Extra-Corporeal Life Support Study. Results: Of the 32 centers [16 low-volume (50%); 16 high-volume (50%)] that responded, 16 (50%) had dedicated ECLS specialists. Twenty-six centers (81.3%) reported using additional mechanical circulatory supports. Anticoagulation practices were highly heterogeneous: 24 hospitals (75%) reported using patients bleeding status as a guide, without a specific threshold in 54.2% of cases. Transfusion targets ranged from 7 to 10 g/dL. Most centers used cardiac venting on a case-by-case basis (78.1%) and regular distal limb perfusion (84.4%). Nineteen (54.9%) centers reported dedicated monitoring protocols, including daily echocardiography (87.5%), Swan-Ganz catheterization (40.6%), cerebral near-infrared spectroscopy (53.1%), and multimodal assessment of limb ischemia. Inspection of the circuit (71.9%), oxygenator pressure drop (68.8%), plasma free hemoglobin (75%), d-dimer (59.4%), lactate dehydrogenase (56.3%), and fibrinogen (46.9%) are used to diagnose hemolysis and thrombosis. Conclusions: This study shows remarkable heterogeneity in clinical practices for PC-ECLS management. More standardized protocols and better implementation of the available evidence are recommended

    Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up

    Get PDF
    Background Congenital hip dysplasia may lead to severe acetabular and femoral abnormalities that can make total hip arthroplasty a challenging procedure. We assessed a series of patients affected by developmental hip dysplasia treated with total hip arthroplasty using cementless tapered stem and here we report the outcomes at long-term follow-up. Materials and methods Twenty-eight patients (24 women and 4 men) aged between 44 and 50 years (mean 47 years) were observed. Clinical evaluation was rated with the Harris Hip Score. Radiographic evaluation consisted in standard anteroposterior and axial view radiographs of the hip. According to Crowe’s classification, 16 hips presented dysplasia grade 1, 14 grade 2, and 4 grade 3. All patients were treated with total hip arthroplasty using a cementless tapered stem (Wagner Cone Prosthesis). Six patients were operated bilaterally, with a totally of 34 hips operated. After surgery, the patients were clinically and radiographically checked at 3, 6, and 12 months and yearly thereafter until an average follow-up of 12 years (range 10–14 years). Results Average Harris Hip Score was 56 ± 9 (range 45–69) preoperatively, 90 ± 9 (range 81–100) 12 months after surgery, and 91 ± 8 (range 83–100) at last follow-up. Radiographic evaluation demonstrated excellent osteointegration of the implants. Signs of bone resorption were present in 6 hips, nevertheless no evidence of loosening was observed and none of the implants has been revised. Conclusions Even in dysplasic femur, the tapered stem allowed adequate stability and orientation of the implant. We consider tapered stem a suitable option for total hip arthroplasty in developmental hip dysplasia, also in case of young patients, thanks to the favourable long-term results

    Can the Reamer/Irrigator/Aspirator System replace anterior iliac crest grafting when treating long bone nonunion?

    No full text
    Introduction: Autologous bone graft is the gold standard for filling bone defects associated with diaphyseal nonunions. It is typically harvested from the anterior iliac crest (AIC) despite the high complication rate. The Reamer/Irrigator/Aspirator System (RIA) was developed to recover the reaming aspirate and use it as autograft. Initially described for harvesting bone from the femur, the bone volume available is similar to the AIC site; however, its use directly at nonunion sites has been studied very little. Hypotheses: Compared to AIC harvesting, RIA at a non-union site will result in (1) sufficient bone volume, (2) similar time to union and union rate, (3) lower morbidity. Results: Two groups of patients received an autograft for aseptic nonunion of the tibia or femur for a bone defect up to 2 cm: the RIA group (n = 30) was followed prospectively and received an autograft by RIA while the AIC group (n = 29) was reviewed retrospectively and received an autograft by AIC. We compared the time to union and union rate, operative time, intake of analgesics, duration of hospital stay and complication rate between groups. The RIA provided sufficient bone, 60 cm 3 on average in a reliable manner. The union rate was similar between groups: 90% (RIA) and 89.7% (CIA) (p = 0.965), while the time to union was shorter in the RIA group (8.63 ± 1.47months vs. 10.08 ± 1.7 months) (p = 0.006). The operative time (p < 0.0001), analgesic intake (p = 0.013), length of stay (p < 0.0001) and immediate complication rate (p = 0.0195) were higher in the AIC group. Discussion: For the treatment of aseptic long bone nonunion, autograft harvested by the RIA from the nonunion site results in similar union rate and time to union as AIC grafts without additional complications. Level of evidence: IV, comparative retrospective study
    corecore