2,931 research outputs found
Quantum dynamics of a high-finesse optical cavity coupled with a thin semi-transparent membrane
We study the quantum dynamics of the cavity optomechanical system formed by a
Fabry-Perot cavity with a thin vibrating membrane at its center. We first
derive the general multimode Hamiltonian describing the radiation pressure
interaction between the cavity modes and the vibrational modes of the membrane.
We then restrict the analysis to the standard case of a single cavity mode
interacting with a single mechanical resonator and we determine to what extent
optical absorption by the membrane hinder reaching a quantum regime for the
cavity-membrane system. We show that membrane absorption does not pose serious
limitations and that one can simultaneously achieve ground state cooling of a
vibrational mode of the membrane and stationary optomechanical entanglement
with state-of-the-art apparatuses.Comment: 14 pages, 7 figure
Sensitivity-bandwidth limit in a multi-mode opto-electro-mechanical transducer
An opto--electro--mechanical system formed by a nanomembrane capacitively
coupled to an LC resonator and to an optical interferometer has been recently
employed for the high--sensitive optical readout of radio frequency (RF)
signals [T. Bagci, \emph{et~al.}, Nature {\bf 507}, 81 (2013)]. Here we propose
and experimentally demonstrate how the bandwidth of such kind of transducer can
be increased by controlling the interference between two--electromechanical
interaction pathways of a two--mode mechanical system. With a
proof--of--principle device \new{operating at room temperature, we achieve a
sensitivity of 300 nV/Hz^(1/2) over a bandwidth of 15 kHz in the presence of
radiofrequency noise, and an optimal shot-noise limited sensitivity of 10
nV/Hz^(1/2) over a bandwidth of 5 kHz. We discuss strategies for improving the
performance of the device, showing that, for the same given sensitivity, a
mechanical multi--mode transducer can achieve a bandwidth} significantly larger
than that of a single-mode one
Optomechanical sideband cooling of a thin membrane within a cavity
We present an experimental study of dynamical back-action cooling of the
fundamental vibrational mode of a thin semitransparent membrane placed within a
high-finesse optical cavity. We study how the radiation pressure interaction
modifies the mechanical response of the vibrational mode, and the experimental
results are in agreement with a Langevin equation description of the coupled
dynamics. The experiments are carried out in the resolved sideband regime, and
we have observed cooling by a factor 350 We have also observed the mechanical
frequency shift associated with the quadratic term in the expansion of the
cavity mode frequency versus the effective membrane position, which is
typically negligible in other cavity optomechanical devices.Comment: 15 pages, 7 figure
Computation of Electrostatic Field near Three-Dimensional Corners and Edges
Theoretically, the electric field becomes infinite at corners of two and
three dimensions and edges of three dimensions. Conventional finite-element and
boundary element methods do not yield satisfactory results at close proximity
to these singular locations. In this paper, we describe the application of a
fast and accurate BEM solver (which usesexact analytic expressions to compute
the effect of source distributions on flatsurfaces) to compute the electric
field near three-dimensional corners and edges. Results have been obtained for
distances as close as 1 near the corner/edge and good agreement has been
observed between the present results and existing analytical solutions.Comment: Presented in International Conference on Computational and
Experimental Engineering and Sciences held at IIT Madras, Chennai, India,
during 1-6 December, 200
Quantum dynamics of a vibrational mode of a membrane within an optical cavity
Optomechanical systems are a promising candidate for the implementation of
quantum interfaces for storing and redistributing quantum information. Here we
focus on the case of a high-finesse optical cavity with a thin vibrating
semitransparent membrane in the middle. We show that robust and stationary
optomechanical entanglement could be achieved in the system, even in the
presence of nonnegligible optical absorption in the membrane. We also present
some preliminary experimental data showing radiation-pressure induced optical
bistability.Comment: 6 pages, 2 figures. Work presented at the conference QCMC 2010 held
on 19-23 July 2010 at the University of Queensland, Brisbane, Australi
Optomechanically induced transparency in membrane-in-the-middle setup at room temperature
We demonstrate the analogue of electromagnetically induced transparency in a
room temperature cavity optomechanics setup formed by a thin semitransparent
membrane within a Fabry-P\'erot cavity. Due to destructive interference, a weak
probe field is completely reflected by the cavity when the pump beam is
resonant with the motional red sideband of the cavity. Under this condition we
infer a significant slowing down of light of hundreds of microseconds, which is
easily tuned by shifting the membrane along the cavity axis. We also observe
the associated phenomenon of electromagnetically induced amplification which
occurs due to constructive interference when the pump is resonant with the blue
sideband.Comment: 5 pages, 4 figure
A Platform for Gastric Cancer Screening in Low- and Middle-Income Countries
Gastric cancer is the second leading cause of cancer death worldwide and screening programs have had a significant impact on reducing mortality. The majority of cases occur in low- and middle-income countries (LMIC), where endoscopy resources are traditionally limited. In this paper, we introduce a platform designed to enable inexpensive gastric screening to take place in remote areas of LMIC. The system consists of a swallowable endoscopic capsule connected to an external water distribution system by a multichannel soft tether. Pressurized water is ejected from the capsule to orient the view of the endoscopic camera. After completion of a cancer screening procedure, the outer shell of the capsule and the soft tether can be disposed, while the endoscopic camera is reclaimed without needing further reprocessing. The capsule, measuring 12 mm in diameter and 28 mm in length, is able to visualize the inside of the gastric cavity by combining waterjet actuation and the adjustment of the tether length. Experimental assessment was accomplished through a set of bench trials, ex vivo analysis, and in vivo feasibility validation. During the ex vivo trials, the platform was able to visualize the main landmarks that are typically observed during a gastric cancer screening procedure in less than 8 min. Given the compact footprint, the minimal cost of the disposable parts, and the possibility of running on relatively available and inexpensive resources, the proposed platform can potentially widen gastric cancer screening programs in LMIC
Tunable linear and quadratic optomechanical coupling for a tilted membrane within an optical cavity: theory and experiment
We present an experimental study of an optomechanical system formed by a
vibrating thin semi-transparent membrane within a high-finesse optical cavity.
We show that the coupling between the optical cavity modes and the vibrational
modes of the membrane can be tuned by varying the membrane position and
orientation. In particular we demonstrate a large quadratic dispersive
optomechanical coupling in correspondence with avoided crossings between
optical cavity modes weakly coupled by scattering at the membrane surface. The
experimental results are well explained by a first order perturbation treatment
of the cavity eigenmodes.Comment: 10 pages, 6 figure
Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC
The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC
proton collider (CERN, Switzerland) will employ an online gas analysis and
monitoring system of the freon-based gas mixture used. We give an overview of
the CMS RPC gas system, describe the project parameters and first results on
gas-chromatograph analysis. Finally, we report on preliminary results for a set
of monitor RPC.Comment: 9 pages, 8 figures. Presented by Stefano Bianco (Laboratori Nazionali
di Frascati dell'INFN) at the IEEE NSS, San Diego (USA), October 200
The permafrost carbon inventory on the Tibetan Plateau : a new evaluation using deep sediment cores
Acknowledgements We are grateful for Dr. Jens Strauss and the other two anonymous reviewers for their insightful comments on an earlier version of this MS, and appreciate members of the IBCAS Sampling Campaign Teams for their assistance in field investigation. This work was supported by the National Basic Research Program of China on Global Change (2014CB954001 and 2015CB954201), National Natural Science Foundation of China (31322011 and 41371213), and the Thousand Young Talents Program.Peer reviewedPostprin
- …
