1,171 research outputs found

    Ion temperatures in HIP-1 and SUMMA from charge-exchange neutral optical emission spectra

    Get PDF
    Ion temperatures were obtained from observations of the H sub alpha, D sub alpha, and He 587.6 nm lines emitted from hydrogen, deuterium, and helium plasmas in the SUMMA and HIP-1 mirror devices at Lewis Research Center. Steady state discharges were formed by applying a radially inward dc electric field between cylindrical or annular anodes and hollow cathodes located at the peaks of the mirrors. The ion temperatures were found from the Doppler broadening of the charge-exchange components of spectral lines. A statistical method was developed for obtaining scaling relations of ion temperature as a function of current, voltage, and magnetic flux density. Derivations are given that take into account triangular monochromator slit functions, loss cones, and superimposed charge-exchange processes. In addition, the Doppler broadening was found to be sensitive to the influence of drift on charge-exchange cross section. The effects of finite ion-cyclotron radius, cascading, and delayed emission are reviewed

    Centroid and moments of an area using a digitizer

    Get PDF
    The centroid and moments of an area program provides the centroid, moments of inertia, product of inertia, radii of gyration, and area of any closed planar geometric figure. The figure must be available in graphic form and is digitized once with chart digitizer (graphic tablet). The digitizer origin may be set anywhere on the digitizer table. After digitizing, fifteen quantities are calculated and displayed: (1) area (2) moment of inertia of area with respect to digitizer x-axis, (3) moment of inertia of area with respect to digitizer y-axis, (4) product of inertia of area with respect to digitizer axes, (5) first moment of x for digitizer axes, (6) first moment of y for digitizer axes, (7) x coordinate of centroid, (8) y coordinate of centroid, (9) moment of area inertia of with respect to x axis through centroid, (10) moment of inertia of area with respect to y axis through centroid, (11) product inertia of area with respect to x and y axes through centroid, (12) polar moment of inertia of area around centroid, (13) radius of gyration about digitizer x axis, (14) radius of gyration about digitizer y-axis; and (15) variance in the x-direction

    Ultrasonic measurement of core material temperature Final report

    Get PDF
    Ultrasonic measurement of core material temperature in nuclear rocket engine

    Reduction of particulate carryover from a pressurized fluidized bed

    Get PDF
    A bench scale fluidized bed combustor was constructed with a conical shape so that the enlarged upper part of the combustor would also serve as a granular bed filter. The combustor was fed coal and limestone. Ninety-nine tests of about four hours each were conducted over a range of conditions. Coal-to-air ratio varied from 0.033 to 0.098 (all lean). Limestone-to-coal ratio varied from 0.06 to 0.36. Bed depth varied from 3.66 to 8.07 feet. Temperature varied from 1447 to 1905 F. Pressure varied from 40 to 82 psia. Heat transfer area had the range zero to 2.72 ft squared. Two cone angles were used. The average particulate carry over of 2.5 grains/SCF was appreciably less than cylindrical fluidized bed combustors. The carry over was correlated by multiple regression analysis to yield the dependence on bed depth and hence the collection efficiency, which was 20%. A comparison with a model indicated that the exhaust port may be below the transport disengaging height for most of the tests, indicating that further reduction in carry over and increase in collection efficiency could be affected by increasing the freeboard and height of the exhaust port above the bed

    Effluent characterization from a conical pressurized fluid bed

    Get PDF
    To obtain useable corrosion and erosion results it was necessary to have data with several levels of particulate matter in the hot gases. One level of particulate loading was as low as possible so that ideally no erosion and only corrosion occurred. A conical fluidized bed was used to obtain some degree of filtration through the top of the bed which would not be highly fluidized. This would minimize the filtration required for the hot gases or conversely the amount of particulate matter in the hot gases after a given level of filtration by cyclones and/or filters. The data obtained during testing characterized the effluent from the bed at different test conditions. A range of bed heights, coal flows, air flows, limestone flows, and pressure are represented. These tests were made to determine the best operating conditions prior to using the bed to determine erosion and corrosion rates of typical turbine blade materials

    Parametric dependence of ion temperature and relative density in the NASA Lewis SUMMA facility

    Get PDF
    Further hot-ion plasma experiments were conducted in the SUMMA superconducting magnetic mirror facility. A steady-state ExB plasma was formed by applying a strong radially inward dc electric field between cylindrical anodes and hollow cathodes located near the magnetic mirror maxima. Extending the use of water cooling to the hollow cathodes, in addition to the anodes, resulted in higher maximum power input to the plasma. Steady-state hydrogen plasmas with ion kinetic temperatures as high as 830 eV were produced. Functional relations were obtained empirically among the plasma current, voltage, magnetic flux density, ion temperature, and relative ion density. The functional relations were deduced by use of a multiple correlation analysis. Data were obtained for midplane magnetic fields from 0.5 to 3.37 tesla and input power up to 45 kW. Also, initial absolute electron density measurements are reported from a 90 deg Thomson scattering laser system

    SUMMA hot-ion plasma heating research at NASA Lewis Research Center

    Get PDF
    The SUMMA superconducting magnetic mirror facility and the associated hot-ion plasma research were described. SUMMA is characterized by intense magnetic fields and a large-diameter working bore (41 cm diameter) with room-temperature access. The goal of the plasma research program is to produce steady-state plasmas of fusion reactor densities and temperatures (but not confinement times). The program includes electrode development to produce a hot, dense, large-volume, steady-state plasma and diagnostics development to document the plasma properties. SUMMA and its hot-ion plasma are ideally suited to develop advanced plasma diagnostics methods. Two such methods whose requirements are well matched to SUMMA are: (1) heavy ion beam probing to measure plasma space potential; and (2) submillimeter wavelength laser Thomson scattering to measure local ion temperature

    Low-cost, compact, cooled photomultiplier assembly for use in magnetic fields up to 1400 Gauss

    Get PDF
    Use of vortex tube for cooling and concentric shielding have produced smaller and more compact unit than was previously available. Future uses of device could include installation in gas chromatographs and mass spectrometers. Additional uses would include measurements and controls in magnetohydrodynamic power generators and fusion reactors

    Ion and electron temperatures in the SUMMA mirror device by emission spectroscopy

    Get PDF
    Ion and electron temperatures, and ion drift were measured in a superconducting magnetic mirror apparatus by observing the Doppler-broadened charge-exchange component of the 667.8 and 587.6 nanometer He lines in He plasma, and the H sub alpha and H sub beta lines in H2 plasma. The second moment of the line profiles was used as the parameter for determining ion temperature. Corrections for magnetic splitting, fine structure, monochromator slit function, and variation in charge-exchange cross section with energy are included. Electron temperatures were measured by the line ratio method for the corona model, and correlations of ion and electron temperatures with plasma parameters are presented

    Examining the Effects of AAC Intervention on Oral Language in Children with Autism Spectrum Disorders: A Systematic Review

    Get PDF
    This systematic review researched the efficacy of augmentative and alternative communication (AAC) in increasing oral communication in children with Autism Spectrum Disorder (ASD). It may be used to inform best practice when working with children with ASD. The search strategy reviewed medical, social science, and communication databases. Inclusionary criteria consisted of peer-reviewed, quantitative research published after 2007 regarding children with ASD under age 18. The included studies used AAC interventions and measured spoken language outcomes. After conducting an initial database search with these criteria, a manual search was performed using references from the found articles. Results varied across studies. Although the trend demonstrates increases in verbal language with AAC intervention, few studies show statistically significant outcomes. The studies indicate that additional factors, such as verbal communication at baseline, may affect outcomes. AAC use did not decrease verbal language. Limitations included few randomized control trial designs, few study replications, and varied outcome measures. Based on the studies analyzed, implementation of AAC may increase the number of communicative acts, but may not reliably increase verbal language. Further research is needed to understand the most effective implementation of AAC intervention to increase verbal language. Higher quality research in the form of randomized control trials, and the replication of studies to confirm results is necessary to inform evidence-based practice. The findings are consistent with those of previous systematic reviews and meta analyses. Future considerations should include type of AAC, communicative act being measured, longitudinal studies, and increased use of formal measures.https://scholarworks.uvm.edu/csdms/1002/thumbnail.jp
    corecore