1,090 research outputs found

    Polynomial Chaos Expansion method as a tool to evaluate and quantify field homogeneities of a novel waveguide RF Wien Filter

    Full text link
    For the measurement of the electric dipole moment of protons and deuterons, a novel waveguide RF Wien filter has been designed and will soon be integrated at the COoler SYnchrotron at J\"ulich. The device operates at the harmonic frequencies of the spin motion. It is based on a waveguide structure that is capable of fulfilling the Wien filter condition (EB\vec{E} \perp \vec{B}) \textit{by design}. The full-wave calculations demonstrated that the waveguide RF Wien filter is able to generate high-quality RF electric and magnetic fields. In reality, mechanical tolerances and misalignments decrease the simulated field quality, and it is therefore important to consider them in the simulations. In particular, for the electric dipole moment measurement, it is important to quantify the field errors systematically. Since Monte-Carlo simulations are computationally very expensive, we discuss here an efficient surrogate modeling scheme based on the Polynomial Chaos Expansion method to compute the field quality in the presence of tolerances and misalignments and subsequently to perform the sensitivity analysis at zero additional computational cost.Comment: 12 pages, 19 figure

    Near-Infrared Sensitized Photocathodes and Film Sensitivities for Typical Xenon-Lamp Radiation and Related Subjects

    Get PDF
    Author Institution: Solid State Physics Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433Weighting or assessment factors of near-infrared photocathodes and Kodak 5424 film are determined for xenon-lamp illumination. These values are important for selecting detectors and determining the basic sensitivity for a given situation and instrumentation; for example, in medicine, when obtaining retinal pictures. Some other typical applications are also discussed. Charts showing the radiation from a xenon-arc lamp, with a 0.5 mm arc length and 800 watt input, and the typical efficiency values of photocathodes and film to xenon-lamp radiation are presented at spectral intervals of 20 nm for the range of 400 to 1100 nm, with and without Kodak Wratten filter 89b

    Electromagnetic Simulation and Design of a Novel Waveguide RF Wien Filter for Electric Dipole Moment Measurements of Protons and Deuterons

    Full text link
    The conventional Wien filter is a device with orthogonal static magnetic and electric fields, often used for velocity separation of charged particles. Here we describe the electromagnetic design calculations for a novel waveguide RF Wien filter that will be employed to solely manipulate the spins of protons or deuterons at frequencies of about 0.1 to 2 MHz at the COoler SYnchrotron COSY at J\"ulich. The device will be used in a future experiment that aims at measuring the proton and deuteron electric dipole moments, which are expected to be very small. Their determination, however, would have a huge impact on our understanding of the universe.Comment: 10 pages, 10 figures, 4 table

    Proton-conducting polymer electrolyte membranes based on fluoropolymers incorporating perfluorovinyl ether sulfonic acids and fluoroalkenes Synthesis and characterizations

    Get PDF
    International audienceThis paper presents the synthesis of new polymer electrolyte membranes based on fluoropolymers incorporating aromatic perfluorovinyl ether sulfonic acids. A novel synthetic route describing the preparation of perfluorovinyl ether monomer containing sulfonic functionalities, 4-[(alpha,beta,beta-trifluorovinyl)oxy]benzene sulfonic acid (TFVOBSA), is reported. The radical (co) and terpolymerization of 4-[(alpha,beta,beta-trifluorovinyl)oxy]benzene sulfonyl chloride (TFVOBSC) with 1,1-difluoroethylene (or vinylidene fluoride, VDF), hexafluoropropene (HFP), and perfluoromethyl vinyl ether (PMVE) is described. The terpolymers of TFVOBSC with VDF and HFP, or VDF and PMVE, were hydrolyzed and led also to original fluorinated terpolymers bearing sulfonic acid aromatic side-group. The terpolymers were characterized by 1H and 19F NMR spectroscopies, SEC, DSC and TGA. Membranes incorporating these functional fluoropolymers were prepared and the electrochemical (IEC, proton conductivity, swelling rates) properties were studied and discussed

    A Precision Measurement of pp Elastic Scattering Cross Sections at Intermediate Energies

    Get PDF
    We have measured differential cross sections for \pp elastic scattering with internal fiber targets in the recirculating beam of the proton synchrotron COSY. Measurements were made continuously during acceleration for projectile kinetic energies between 0.23 and 2.59 GeV in the angular range 30θc.m.9030 \leq \theta_{c.m.} \leq 90 deg. Details of the apparatus and the data analysis are given and the resulting excitation functions and angular distributions presented. The precision of each data point is typically better than 4%, and a relative normalization uncertainty of only 2.5% within an excitation function has been reached. The impact on phase shift analysis as well as upper bounds on possible resonant contributions in lower partial waves are discussed.Comment: 23 pages 29 figure

    Do residents’ perceptions of being well-placed and objective presence of local amenities match? A case study in West Central Scotland, UK

    Get PDF
    Background:<p></p> Recently there has been growing interest in how neighbourhood features, such as the provision of local facilities and amenities, influence residents’ health and well-being. Prior research has measured amenity provision through subjective measures (surveying residents’ perceptions) or objective (GIS mapping of distance) methods. The latter may provide a more accurate measure of physical access, but residents may not use local amenities if they do not perceive them as ‘local’. We believe both subjective and objective measures should be explored, and use West Central Scotland data to investigate correspondence between residents’ subjective assessments of how well-placed they are for everyday amenities (food stores, primary and secondary schools, libraries, pharmacies, public recreation), and objective GIS-modelled measures, and examine correspondence by various sub-groups.<p></p> Methods:<p></p> ArcMap was used to map the postal locations of ‘Transport, Health and Well-being 2010 Study’ respondents (n = 1760), and the six amenities, and the presence/absence of each of them within various straight-line and network buffers around respondents’ homes was recorded. SPSS was used to investigate whether objective presence of an amenity within a specified buffer was perceived by a respondent as being well-placed for that amenity. Kappa statistics were used to test agreement between measures for all respondents, and by sex, age, social class, area deprivation, car ownership, dog ownership, walking in the local area, and years lived in current home.<p></p> Results:<p></p> In general, there was poor agreement (Kappa <0.20) between perceptions of being well-placed for each facility and objective presence, within 800 m and 1000 m straight-line and network buffers, with the exception of pharmacies (at 1000 m straight-line) (Kappa: 0.21). Results varied between respondent sub-groups, with some showing better agreement than others. Amongst sub-groups, at 800 m straight-line buffers, the highest correspondence between subjective and objective measures was for pharmacies and primary schools, and at 1000 m, for pharmacies, primary schools and libraries. For road network buffers under 1000 m, agreement was generally poor.<p></p> Conclusion:<p></p> Respondents did not necessarily regard themselves as well-placed for specific amenities when these amenities were present within specified boundaries around their homes, with some exceptions; the picture is not clear-cut with varying findings between different amenities, buffers, and sub-groups

    New determination of the mass of the eta meson at COSY-ANKE

    Get PDF
    A value for the mass of the eta meson has been determined at the COSY-ANKE facility through the measurement of a set of deuteron laboratory beam momenta and associated 3He center-of-mass momenta in the d+p -> 3He+X reaction. The eta was then identified by the missing-mass peak and the production threshold determined. The individual beam momenta were fixed with a relative precision of 3 x 10^-5 for values around 3 GeV/c by using a polarized deuteron beam and inducing an artificial depolarizing spin resonance, which occurs at a well-defined frequency. The final-state momenta in the two-body d+p -> 3He+eta reaction were investigated in detail by studying the size of the 3He momentum ellipse with the forward detection system of the ANKE spectrometer. Final alignment of the spectrometer for this high precision experiment was achieved through a comprehensive study of the 3He final-state momenta as a function of the center-of-mass angles, taking advantage of the full geometrical acceptance. The value obtained for the mass, m(eta)=(547.873 +- 0.005(stat) +- 0.027(syst)) MeV/c^2, is consistent and competitive with other recent measurements, in which the meson was detected through its decay products.Comment: 11 pages, 11 figures, 3 tables, published versio

    Measurement of Spin Correlation Parameters ANN_{NN}, ASS_{SS}, and A_SL{SL} at 2.1 GeV in Proton-Proton Elastic Scattering

    Full text link
    At the Cooler Synchrotron COSY/J\"ulich spin correlation parameters in elastic proton-proton (pp) scattering have been measured with a 2.11 GeV polarized proton beam and a polarized hydrogen atomic beam target. We report results for ANN_{NN}, ASS_{SS}, and A_SL{SL} for c.m. scattering angles between 30o^o and 90o^o. Our data on ASS_{SS} -- the first measurement of this observable above 800 MeV -- clearly disagrees with predictions of available of pp scattering phase shift solutions while ANN_{NN} and A_SL{SL} are reproduced reasonably well. We show that in the direct reconstruction of the scattering amplitudes from the body of available pp elastic scattering data at 2.1 GeV the number of possible solutions is considerably reduced.Comment: 4 pages, 4 figure
    corecore