816 research outputs found
GLAST: Understanding the High Energy Gamma-Ray Sky
We discuss the ability of the GLAST Large Area Telescope (LAT) to identify,
resolve, and study the high energy gamma-ray sky. Compared to previous
instruments the telescope will have greatly improved sensitivity and ability to
localize gamma-ray point sources. The ability to resolve the location and
identity of EGRET unidentified sources is described. We summarize the current
knowledge of the high energy gamma-ray sky and discuss the astrophysics of
known and some prospective classes of gamma-ray emitters. In addition, we also
describe the potential of GLAST to resolve old puzzles and to discover new
classes of sources.Comment: To appear in Cosmic Gamma Ray Sources, Kluwer ASSL Series, Edited by
K.S. Cheng and G.E. Romer
Effects of reallocating time in different activity intensities on health and fitness: a cross sectional study
BACKGROUND:
The effects of replacing time in specific activity categories for other categories (e.g. replacing sedentary time with light activity) on health and fitness are not well known. This study used isotemporal substitution to investigate the effects of substituting activity categories in an equal time exchange fashion on health and fitness in young people.
METHODS:
Participants were drawn from schools in Camden, London (n = 353, mean age 9.3 ± 2.3 years). Time sedentary, in light and in moderate-to-vigorous activity (MVPA) was measured via accelerometry. The effects of substituting time in activity categories (sedentary, light and MVPA) with equivalent time in another category on health and fitness were examined using isotemporal substitution.
RESULTS:
In single and partition models, MVPA was favourably associated with body fat %, horizontal jump distance and flexibility. Time sedentary and in light activity were not associated with health and fitness outcomes in these models. In substitution models, replacing one hour of sedentary time with MVPA was favourably associated with body fat % (B = -4.187; 95% confidence interval (CI), -7.233, -1.142), horizontal jump distance (B = 16.093; 95% CI, 7.476, 24.710) and flexibility (B = 4.783; 95% CI, 1.910, 7.656). Replacing time in light activity with MVPA induced similar benefits but there were null effects for replacing sedentary with light intensity.
CONCLUSION:
Substituting time sedentary and in light activity with MVPA was associated with favourable health and fitness. Time in sedentary behaviour may only be detrimental to health and fitness when it replaces time in MVPA in young people
Detection of Gamma-Ray Emission from the Starburst Galaxies M82 and NGC 253 with the Large Area Telescope on Fermi
We report the detection of high-energy gamma-ray emission from two starburst
galaxies using data obtained with the Large Area Telescope on board the Fermi
Gamma-ray Space Telescope. Steady point-like emission above 200 MeV has been
detected at significance levels of 6.8 sigma and 4.8 sigma respectively, from
sources positionally coincident with locations of the starburst galaxies M82
and NGC 253. The total fluxes of the sources are consistent with gamma-ray
emission originating from the interaction of cosmic rays with local
interstellar gas and radiation fields and constitute evidence for a link
between massive star formation and gamma-ray emission in star-forming galaxies.Comment: Submitted to ApJ Letter
Positron annihilation signatures associated with the outburst of the microquasar V404 Cygni
This document is the Accepted Manuscript version of the following article: Thomas Siegert, et al, ‘Positron annihilation signatures associated with the outburst of the microquasar V404 Cygni’, Nature: International Journal of Science, Vol. 531: 341-343, March 2016, DOI: https://doi.org/10.1038/nature16978. Content in the UH Research Archive is made available for personal research, educational, and non-commercial purposes only. Unless otherwise stated, all content is protected by copyright, and in the absence of an open license, permissions for further re-use should be sought from the publisher, the author, or other copyright holder.Microquasars1, 2, 3, 4 are stellar-mass black holes accreting matter from a companion star5 and ejecting plasma jets at almost the speed of light. They are analogues of quasars that contain supermassive black holes of 106 to 1010 solar masses. Accretion in microquasars varies on much shorter timescales than in quasars and occasionally produces exceptionally bright X-ray flares6. How the flares are produced is unclear, as is the mechanism for launching the relativistic jets and their composition. An emission line near 511 kiloelectronvolts has long been sought in the emission spectrum of microquasars as evidence for the expected electron–positron plasma. Transient high-energy spectral features have been reported in two objects7, 8, but their positron interpretation9 remains contentious. Here we report observations of γ-ray emission from the microquasar V404 Cygni during a recent period of strong flaring activity10. The emission spectrum around 511 kiloelectronvolts shows clear signatures of variable positron annihilation, which implies a high rate of positron production. This supports the earlier conjecture that microquasars may be the main sources of the electron–positron plasma responsible for the bright diffuse emission of annihilation γ-rays in the bulge region of our Galaxy11. Additionally, microquasars could be the origin of the observed megaelectronvolt continuum excess in the inner Galaxy.Peer reviewe
Observation of associated near-side and away-side long-range correlations in √sNN=5.02 TeV proton-lead collisions with the ATLAS detector
Two-particle correlations in relative azimuthal angle (Δϕ) and pseudorapidity (Δη) are measured in √sNN=5.02 TeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1 μb-1 of data as a function of transverse momentum (pT) and the transverse energy (ΣETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Δη|<5) “near-side” (Δϕ∼0) correlation that grows rapidly with increasing ΣETPb. A long-range “away-side” (Δϕ∼π) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ΣETPb, is found to match the near-side correlation in magnitude, shape (in Δη and Δϕ) and ΣETPb dependence. The resultant Δϕ correlation is approximately symmetric about π/2, and is consistent with a dominant cos2Δϕ modulation for all ΣETPb ranges and particle pT
Evidence for the h_b(1P) meson in the decay Upsilon(3S) --> pi0 h_b(1P)
Using a sample of 122 million Upsilon(3S) events recorded with the BaBar
detector at the PEP-II asymmetric-energy e+e- collider at SLAC, we search for
the spin-singlet partner of the P-wave chi_{bJ}(1P) states in the
sequential decay Upsilon(3S) --> pi0 h_b(1P), h_b(1P) --> gamma eta_b(1S). We
observe an excess of events above background in the distribution of the recoil
mass against the pi0 at mass 9902 +/- 4(stat.) +/- 2(syst.) MeV/c^2. The width
of the observed signal is consistent with experimental resolution, and its
significance is 3.1sigma, including systematic uncertainties. We obtain the
value (4.3 +/- 1.1(stat.) +/- 0.9(syst.)) x 10^{-4} for the product branching
fraction BF(Upsilon(3S)-->pi0 h_b) x BF(h_b-->gamma eta_b).Comment: 8 pages, 4 postscript figures, submitted to Phys. Rev. D (Rapid
Communications
Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector
The inclusive and dijet production cross-sections have been measured for jets
containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass
energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The
measurements use data corresponding to an integrated luminosity of 34 pb^-1.
The b-jets are identified using either a lifetime-based method, where secondary
decay vertices of b-hadrons in jets are reconstructed using information from
the tracking detectors, or a muon-based method where the presence of a muon is
used to identify semileptonic decays of b-hadrons inside jets. The inclusive
b-jet cross-section is measured as a function of transverse momentum in the
range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet
cross-section is measured as a function of the dijet invariant mass in the
range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets
and the angular variable chi in two dijet mass regions. The results are
compared with next-to-leading-order QCD predictions. Good agreement is observed
between the measured cross-sections and the predictions obtained using POWHEG +
Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet
cross-section. However, it does not reproduce the measured inclusive
cross-section well, particularly for central b-jets with large transverse
momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final
version published in European Physical Journal
Light-intensity physical activity and cardiometabolic biomarkers in US adolescents
BackgroundThe minimal physical activity intensity that would confer health benefits among adolescents is unknown. The purpose of this study was to examine the associations of accelerometer-derived light-intensity (split into low and high) physical activity, and moderate- to vigorous-intensity physical activity with cardiometabolic biomarkers in a large population-based sample.MethodsThe study is based on 1,731 adolescents, aged 12–19 years from the 2003/04 and 2005/06 National Health and Nutrition Examination Survey. Low light-intensity activity (100–799 counts/min), high light-intensity activity (800 counts/min to <4 METs) and moderate- to vigorous-intensity activity (≥4 METs, Freedson age-specific equation) were accelerometer-derived. Cardiometabolic biomarkers, including waist circumference, systolic blood pressure, diastolic blood pressure, HDL-cholesterol, and C-reactive protein were measured. Triglycerides, LDL- cholesterol, insulin, glucose, and homeostatic model assessments of β-cell function (HOMA-%B) and insulin sensitivity (HOMA-%S) were also measured in a fasting sub-sample (n=807).ResultsAdjusted for confounders, each additional hour/day of low light-intensity activity was associated with 0.59 (95% CI: 1.18–0.01) mmHG lower diastolic blood pressure. Each additional hour/day of high light-intensity activity was associated with 1.67 (2.94–0.39) mmHG lower diastolic blood pressure and 0.04 (0.001–0.07) mmol/L higher HDL-cholesterol. Each additional hour/day of moderate- to vigorous-intensity activity was associated with 3.54 (5.73–1.35) mmHG lower systolic blood pressure, 5.49 (1.11–9.77)% lower waist circumference, 25.87 (6.08–49.34)% lower insulin, and 16.18 (4.92–28.53)% higher HOMA-%S.ConclusionsTime spent in low light-intensity physical activity and high light-intensity physical activity had some favorable associations with biomarkers. Consistent with current physical activity recommendations for adolescents, moderate- to vigorous-intensity activity had favorable associations with many cardiometabolic biomarkers. While increasing MVPA should still be a public health priority, further studies are needed to identify dose-response relationships for light-intensity activity thresholds to inform future recommendations and interventions for adolescents.</div
Validity and reliability of a modified english version of the physical activity questionnaire for adolescents
BACKGROUND: Adaptation of physical activity self-report questionnaires is sometimes required to reflect the activity behaviours of diverse populations. The processes used to modify self-report questionnaires though are typically underreported. This two-phased study used a formative approach to investigate the validity and reliability of the Physical Activity Questionnaire for Adolescents (PAQ-A) in English youth. Phase one examined test content and response process validity and subsequently informed a modified version of the PAQ-A. Phase two assessed the validity and reliability of the modified PAQ-A. METHODS: In phase one, focus groups (n = 5) were conducted with adolescents (n = 20) to investigate test content and response processes of the original PAQ-A. Based on evidence gathered in phase one, a modified version of the questionnaire was administered to participants (n = 169, 14.5 ± 1.7 years) in phase two. Internal consistency and test-retest reliability were assessed using Cronbach’s alpha and intra-class correlations, respectively. Spearman correlations were used to assess associations between modified PAQ-A scores and accelerometer-derived physical activity, self-reported fitness and physical activity self-efficacy. RESULTS: Phase one revealed that the original PAQ-A was unrepresentative for English youth and that item comprehension varied. Contextual and population/cultural-specific modifications were made to the PAQ-A for use in the subsequent phase. In phase two, modified PAQ-A scores had acceptable internal consistency (α = 0.72) and test-retest reliability (ICC = 0.78). Modified PAQ-A scores were significantly associated with objectively assessed moderate-to-vigorous physical activity (r = 0.39), total physical activity (r = 0.42), self-reported fitness (r = 0.35), and physical activity self-efficacy (r = 0.32) (p ≤ 0.01). CONCLUSIONS: The modified PAQ-A had acceptable internal consistency and test-retest reliability. Modified PAQ-A scores displayed weak-to-moderate correlations with objectively measured physical activity, self-reported fitness, and self-efficacy providing evidence of satisfactory criterion and construct validity, respectively. Further testing with more diverse English samples is recommended to provide a more complete assessment of the tool. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13690-016-0115-2) contains supplementary material, which is available to authorized users
Actigraph Accelerometer-Defined Boundaries for Sedentary Behaviour and Physical Activity Intensities in 7 Year Old Children
Background: Accurate objective assessment of sedentary and physical activity behaviours during childhood is integral to the understanding of their relation to later health outcomes, as well as to documenting the frequency and distribution of physical activity within a population.Purpose: To calibrate the Actigraph GT1M accelerometer, using energy expenditure (EE) as the criterion measure, to define thresholds for sedentary behaviour and physical activity categories suitable for use in a large scale epidemiological study in young children.Methods: Accelerometer-based assessments of physical activity (counts per minute) were calibrated against EE measures (kcal.kg(-1).hr(-1)) obtained over a range of exercise intensities using a COSMED K4b(2) portable metabolic unit in 53 seven-year-old children. Children performed seven activities: lying down viewing television, sitting upright playing a computer game, slow walking, brisk walking, jogging, hopscotch and basketball. Threshold count values were established to identify sedentary behaviour and light, moderate and vigorous physical activity using linear discriminant analysis (LDA) and evaluated using receiver operating characteristic (ROC) curve analysis.Results: EE was significantly associated with counts for all non-sedentary activities with the exception of jogging. Threshold values for accelerometer counts (counts. minute(-1)) were = 3841 for light, moderate and vigorous physical activity respectively. The area under the ROC curves for discrimination of sedentary behaviour and vigorous activity were 0.98. Boundaries for light and moderate physical activity were less well defined (0.61 and 0.60 respectively). Sensitivity and specificity were higher for sedentary (99% and 97%) and vigorous (95% and 91%) than for light (60% and 83%) and moderate (61% and 76%) thresholds.Conclusion: The accelerometer cut points established in this study can be used to classify sedentary behaviour and to distinguish between light, moderate and vigorous physical activity in children of this age
- …
