722 research outputs found

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Experimental studies of e + e -→ some charmless processes containing K S0 at √s = 3.773 and 3.65 GeV

    Get PDF
    We measure the observed cross sections for the charmless processes e + e -→K S0 K - K - K + π ++ c.c., K S0 K - π + η+c.c., K S0 K - π + π + π - η+c.c., K S0 K - K - K + π + η+c.c., K S0 K - K - K + π + π 0+c.c., K S0 K - ρ ++c.c. and K S0 K - π + ρ 0+c.c. We also extract upper limits on the branching fractions for ψ(3770) decays into these final states at 90% C.L. Analyzed data samples correspond to 17.3 pb-1 and 6.5 pb-1 integrated luminosities registered, respectively, at √s = 3.773 and 3.65 GeV, with the BES-II detector at the BEPC collider. © 2009 Springer-Verlag / Società Italiana di Fisica.published_or_final_versionSpringer Open Choice, 21 Feb 201

    Measurement of Higgs boson production and properties in the WW decay channel with leptonic final states

    Get PDF
    Peer reviewe

    Search for ψ(3770)→ charmless final states involving η or π0 mesons

    Get PDF
    We search for ψ(3770) → π+π-η, K+K-η, pp̄η, ρ0π+π-η, K+K-π+π-η, pp̄π+π-η, pp̄K+K-η and pp̄K+K- π0 using data samples of 17.3 and 6.5 pb-1 integrated luminosities recorded at the center-of-mass energies of 3.773 and 3.65 GeV, respectively, by the BES-II detector operating at the BEPC collider. We obtain cross section measurements at both energies and upper limits on ψ(3770) decay branching fractions to the final states studied. © © Springer-Verlag / Società Italiana di Fisica 2010.published_or_final_versionSpringer Open Choice, 21 Feb 201

    Study of double parton scattering using W+2-jet events in proton-proton collisions at √s=7 TeV

    Get PDF
    Peer reviewe

    Search for Dark Matter and Supersymmetry with a Compressed Mass Spectrum in the Vector Boson Fusion Topology in Proton-Proton Collisions at root s=8 TeV

    Get PDF
    Peer reviewe

    Identification and Filtering of Uncharacteristic Noise in the CMS Hadron Calorimeter

    Get PDF
    VertaisarvioitupeerReviewe

    Parenteral thiamine for prevention and treatment of delirium in critically ill adults: a systematic review protocol

    Get PDF
    Background: Delirium is an acute confusional state, common in critical illness and associated with cognitive decline. There is no effective pharmacotherapy to prevent or treat delirium, although it is scientifically plausible that thiamine could be effective. Thiamine studies in dementia patients are inconclusive. Aside from small numbers, all used oral administration: bioavailability of thiamine is poor; parenteral thiamine bypasses this. In the UK, parenteral thiamine is administered as a compound vitamin B and C solution (Pabrinex®). The aim of this review is to evaluate the effectiveness of parenteral thiamine (alone or in a compound solution) in preventing or treating delirium in critical illness. Methods: We will search for studies in electronic databases (MEDLINE (Pro-Quest), EMBASE, CINAHL, LILACS, CNKI, AMED, and Cochrane CENTRAL), clinical trials registries (WHO International Clinical Trials Registry, ClinicalTrials.gov, and Controlled-trials.com), and grey literature (Google Scholar, conference proceedings, and Index to Theses). We will perform complementary searches of reference lists of included studies, relevant reviews, clinical practice guidelines, or other pertinent documents (e.g. official documents and government reports). We will consider quasi-randomised or randomised controlled trials in critically ill adults. We will include studies that evaluate parenteral thiamine versus standard of care, placebo, or any other non-pharmacological or pharmacological interventions. The primary outcomes will be the delirium core outcome set, including incidence and severity of delirium and cognition. Secondary outcomes are adapted from the ventilation core outcome set: duration of mechanical ventilation, length of stay, and adverse events incidence. Screening, data extraction, and risk of bias assessment will be undertaken independently by two reviewers. If data permits, we will conduct meta-analyses using a random effects model and, where appropriate, sensitivity and subgroup analyses to explore sources of heterogeneity. Discussion: This review will provide evidence for the effectiveness of parental thiamine in the prevention or treatment of delirium in critical care. Findings will contribute to establishing the need for a multicentre study of parenteral thiamine in the prevention and treatment of critical care delirium. Systematic review registration: PROSPERO CRD42019118808.This article is freely available via Open Access. Click on the Publisher URL to access it via the publisher's site.published version, accepted versio
    corecore