349 research outputs found

    Ionization Quenching Factor Measurement of Helium 4

    Get PDF
    The ionization quenching factor (IQF) is defined as the fraction of energy released by a recoil in a medium through ionization compared with its total kinetic energy. At low energies, in the range of a few keV, the ionization produced in a medium falls rapidly and systematic measurements are needed. We report measurements carried out at such low energies as a function of the pressure in He4 at 350, 700, 1000 and 1300 mbar. In order to produce a nucleus moving with a controlled energy in the detection volume, we have developed an Electron Cyclotron Resonance Ion Source (ECRIS) coupled to an ionization chamber by a differential pumping. The quenching factor of He4 has been measured for the first time down to 1 keV recoil energies. An important deviation with respect to the phenomenological calculations has been found allowing an estimation of the scintillation produced in He4 as a function of pressure. The variation of the IQF as a function of the percentage of isobutane, used as quencher, is also presented

    Roche-la-Molière – Les roches meulières

    Get PDF
    Plus communément appelé le site des Rieux, sur le versant sud de cet affleurement rocheux, le site se nomme les Appends/Côte Chez Nous. Il est situé à une altitude comprise entre 490 et 535 m, au nord-ouest de la commune de Roche la Molière. Alain Belmont se déplace en 2009 sur le site des Rieux, montrant une extraction meulière peut-être locale à l’origine de cette exploitation. On y retrouve des meules de 136 cm de diamètre, non décollées du substrat, qui pourraient être contemporaines d’..

    Amyloid Precursor-Like Protein 2 deletion-induced retinal synaptopathy related to congenital stationary night blindness: structural, functional and molecular characteristics.

    Get PDF
    Amyloid precursor protein knockout mice (APP-KO) have impaired differentiation of amacrine and horizontal cells. APP is part of a gene family and its paralogue amyloid precursor-like protein 2 (APLP2) has both shared as well as distinct expression patterns to APP, including in the retina. Given the impact of APP in the retina we investigated how APLP2 expression affected the retina using APLP2 knockout mice (APLP2-KO). Using histology, morphometric analysis with noninvasive imaging technique and electron microscopy, we showed that APLP2-KO retina displayed abnormal formation of the outer synaptic layer, accompanied with greatly impaired photoreceptor ribbon synapses in adults. Moreover, APLP2-KO displayed a significant decease in ON-bipolar, rod bipolar and type 2 OFF-cone bipolar cells (36, 21 and 63 %, respectively). Reduction of the number of bipolar cells was accompanied with disrupted dendrites, reduced expression of metabotropic glutamate receptor 6 at the dendritic tips and alteration of axon terminals in the OFF laminae of the inner plexiform layer. In contrast, the APP-KO photoreceptor ribbon synapses and bipolar cells were intact. The APLP2-KO retina displayed numerous phenotypic similarities with the congenital stationary night blindness, a non-progressive retinal degeneration disease characterized by the loss of night vision. The pathological phenotypes in the APLP2-KO mouse correlated to altered transcription of genes involved in pre- and postsynatic structure/function, including CACNA1F, GRM6, TRMP1 and Gα0, and a normal scotopic a-wave electroretinogram amplitude, markedly reduced scotopic electroretinogram b-wave and modestly reduced photopic cone response. This confirmed the impaired function of the photoreceptor ribbon synapses and retinal bipolar cells, as is also observed in congenital stationary night blindness. Since congenital stationary night blindness present at birth, we extended our analysis to retinal differentiation and showed impaired differentiation of different bipolar cell subtypes and an altered temporal sequence of development from OFF to ON laminae in the inner plexiform layer. This was associated with the altered expression patterns of bipolar cell generation and differentiation factors, including MATH3, CHX10, VSX1 and OTX2. These findings demonstrate that APLP2 couples retina development and synaptic genes and present the first evidence that APLP2 expression may be linked to synaptic disease

    Une didactique de la langue, de la culture, et du genre. Le manuel de FLE : discours et réalisations

    Get PDF
    L’enseignement-apprentissage du Français comme une Langue Etrangère (FLE) se caractérise par l’hétérogénéité de ses situations pédagogiques. Mais ses ressources didactiques comportent aussi des marques de subjectivité qui sont propres à leur contexte de production. C’est pour déceler les marques d’une politique de genre à l’œuvre dans les manuels de FLE que cette recherche a été entreprise. Partant d’une conceptualisation du genre comme un discours non-déclaré (Maurer 2002), didactiquement tr..

    Calibration of the surface array of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is designed to study cosmic rays of the highest energies (>101910^{19}eV). The ground array of the Observatory will consist of 1600 water Cherenkov detectors deployed over 3000 km2^2. The remoteness and large number of detectors require a robust, automatic self-calibration procedure. It relies on the measurement of the average charge collected by a photomultiplier tube from the Cherenkov light produced by a vertical and central through-going muon, determined to 5–10% at the detector via a novel rate-based technique and to 3% precision through analysis of histograms of the charge distribution. The parameters needed for the calibration are measured every minute, allowing for an accurate determination of the signals recorded from extensive air showers produced by primary cosmic rays. The method also enables stable and uniform triggering conditions to be achieved

    Eliminating the need for preoperative intravenous hyperhydration: Sodium thiosulfate as nephrotoxicity prevention in HIPEC-treated patients - A retrospective analysis.

    Get PDF
    Cytoreductive surgery with hyperthermic intraperitoneal chemotherapy (HIPEC) is an effective treatment for peritoneal metastases. However, HIPEC with cisplatin is associated with renal toxicity. Sodium thiosulfate (ST) has been shown to prevent cisplatin-induced toxicity. A retrospective, single-center analysis of patients treated curatively for peritoneal surface malignancy, who underwent cytoreductive surgery with cisplatin-based HIPEC between 2015 and 2020. Patients were categorized into three groups based on the management of cisplatin-induced renal toxicity: preoperative hyperhydration alone (PHH), preoperative hyperhydration with ST (PHH + ST), and ST alone. Renal function and complications, in terms of Acute (AKI) and chronic kidney injury (CKI), were monitored and analyzed during 3 postoperative months. This study included 220 consecutive patients. Mean serum creatinine levels were 95, 57 and 61 mmol/L, for PHH, PHH + ST and ST groups, respectively (p < 0.001). Glomerular Filtration Rate (GFR) were 96, 94 and 78 ml/min/1.73 m <sup>2</sup> , respectively (p < 0.001). AKI and CKI are respectively for PHH, PHH + ST and ST groups were 21 % (n = 46), 1 % (n = 2) and 0 % vs 19 % (n = 42), 0 % and 0 % (p < 0.001), for pairwise analysis did not show any difference between PHH + ST and ST alone combination, regarding nephrological outcomes. All patients were followed 3 months postoperatively. There is no need for preoperative hyperhydration when sodium-thiosulfate is used to prevent cisplatin-induced nephrotoxicity in patients undergoing cytoreductive surgery with HIPEC. These findings have implications for improving and simplifying the management of patients with peritoneal metastases undergoing HIPEC with cisplatin

    Explanation of the Colour Change in Alexandrites.

    Get PDF
    Alexandrites are remarkable and rare gemstones. They display an extraordinary colour change according to the ambient lighting, from emerald green in daylight to ruby red in incandescent light from tungsten lamps or candles. While this colour change has been correctly attributed to chromium impurities and their absorption band in the yellow region of the visible light spectrum, no adequate explanation of the mechanism has been given. Here, the alexandrite effect is fully explained by considering the von Kries model of the human colour constancy mechanism. This implies that our colour constancy mechanism is real (objective) and primarily attuned to correct for the colour temperature of black-body illuminants

    Muon Flux at the Geographical South Pole

    Full text link
    The muon flux at the South-Pole was measured for five zenith angles, 00^{\circ}, 1515^{\circ}, 3535^{\circ}, 82.1382.13^{\circ} and 85.1585.15^{\circ} with a scintillator muon telescope incorporating ice Cherenkov tank detectors as the absorber. We compare the measurements with other data and with calculations.Comment: 14 pages, 6 figure
    corecore