826 research outputs found

    Use of a colonoscope for distal duodenal stent placement in patients with malignant obstruction

    Get PDF
    Background: Stent placement in the distal duodenum or proximal jejunum with a therapeutic gastroscope can be difficult, because of the reach of the endoscope, loop formation in the stomach, and flexibility of the gastroscope. The use of a colonoscope may overcome these problems. Objective: To report our experience with distal duodenal stent placement in 16 patients using a colonoscope. Methods: Multicenter, retrospective series of patients with a malignant obstruction at the level of the distal duodenum and proximal jejunum and treated by stent placement using a colonoscope. Main outcome measurements are technical success, ability to eat, complications, and survival. Results: Stent placement was technically feasible in 93% (15/16) of patients. Food intake improved from a median gastric outlet obstruction scoring system (GOOSS) score of 1 (no oral intake) to 3 (soft solids) (p = 0.001). Severe complications were not observed. One patient had persistent obstructive symptoms presumably due to motility problems. Recurrent obstructive symptoms were caused by tissue/tumor ingrowth through the stent mesh [n = 6 (38%)] and stent occlusion by debris [n = 1 (6%)]. Reinterventions included additional stent placement [n = 5 (31%)], gastrojejunostomy [n = 2 (12%)], and endoscopic stent cleansing [n = 1 (6%)]. Median survival was 153 days. Conclusion: Duodenal stent placement can effectively and safely be performed using a colonoscope in patients with an obstruction at the level of the distal duodenum or proximal jejunum. A colonoscope has the advantage that it is long enough and offers good endoscopic stiffness, which avoids looping in the stomach

    Balanced Propofol Sedation in Patients Undergoing EUS-FNA: A Pilot Study to Assess Feasibility and Safety

    Get PDF
    Introduction and aims. Balanced propofol sedation (BPS) administered by gastroenterologists has gained popularity in endoscopic procedures. Few studies exist about the safety of this approach during endosonography with fine needle aspiration (EUS-FNA). We assessed the safety of BPS in EUS-FNA. Materials and methods. 112 consecutive patients, referred to our unit to perform EUS-FNA, from February 2008 to December 2009, were sedated with BPS. A second gastroenterologist administered the drugs and monitorized the patient. Results. All the 112 patients (62 males, mean age 58.35) completed the examination. The mean dose of midazolam and propofol was, respectively, of 2.1 mg (range 1–4 mg) and 350 mg (range 180–400). All patients received oxygen with a mean flux of 4 liter/minute (range 2–6 liters/minute). The mean recovery time after procedure was 25 minutes (range 18–45 minutes). No major complications related to sedation were registered during all procedures. The oxygen saturation of all patients never reduced to less than 85%. Blood systolic pressure during and after the procedure never reduced to less than 100 mmHg. Conclusions. In our experience BPS administered by non-anaesthesiologists provided safe and successful sedation in patients undergoing EUS-FNA

    The Derivation and External Validation of a Fibrosis Risk Model for Colorectal Tumours Undergoing Endoscopic Submucosal Dissection

    Get PDF
    Background: Endoscopic submucosal dissection (ESD) is an advanced technique that can become more challenging in the presence of submucosal fibrosis. Predicting the grade of fibrosis is important in order to identify technically difficult ESD. Aims and Methods: Our study aimed to derive and validate a prediction model to determine the preoperative degree of submucosal fibrosis in colorectal tumours undergoing ESD. A predictive model was developed to derive the probability of an increasing submucosal fibrosis in the derivation cohort and then externally validated. Results: 309 patients (age: 68 ± 10.9 years) underwent colorectal ESD between January 2016 and June 2020. F0, F1, and F2 fibroses were reported in 196 (63.4%), 70 (22.6%), and 43 (13.9%) cases, respectively. R0 resection was found in 266 (87%) lesions. At multivariable analysis in the derivation cohort, lesion morphology (OR = 0.37 and CI = 0.14–0.97 for LST-NG vs. 0-Is; OR = 0.29 and CI = 0.1–0.87 for the LST mixed type vs. 0-Is; and OR = 0.32 and CI = 0.1–1.03 for LST-G vs. 0-Is) and increasing size (OR = 1.02 and CI = 1.01–1.04 for a 1 mm increase) were significantly associated with an increasing degree of fibrosis. The model had fair discriminating ability in the derivation group (AUROC = 0.61 and CI = 0.52–0.69 for F1–F2 vs. F0 fibroses; AUROC = 0.61 and CI = 0.45–0.77 for F2 vs. F0–F1 fibroses) and in the validation group (AUROC = 0.71 and CI = 0.59–0.83 for F1–F2 vs. F0 fibroses; AUROC = 0.65 and CI = 0.52–0.77 for F2 vs. F0–F1 fibroses). Conclusions: Our findings introduce a new tool for the stratification of ESD technical difficulty based on lesion size and morphological characteristics which could become crucial during the procedure’s planning process

    Endoscopic ultrasound-guided ablation of solid pancreatic lesions: A systematic review of early outcomes with pooled analysis

    Get PDF
    Contains fulltext : 252157.pdf (Publisher’s version ) (Open Access)BACKGROUND: Endoscopic ultrasound-guided radiofrequency ablation (EUS-RFA) is emerging as a complementary therapeutic approach for pancreatic solid masses. However, results of published data are difficult to interpret because of a retrospective design and small sample size. AIM: To systematically review data on EUS-RFA for solid lesions and to pool the results of the different experiences in order to provide more consistent evidence in terms of safety and efficacy. METHODS: A comprehensive systematic literature search on the main databases was performed to identify articles in which patients with pancreatic solid lesions underwent EUS-RFA. The primary outcomes were procedure-related adverse events (AEs) and mortality. Secondary outcomes were the technical success rate and the effects on primary tumor growth. Statistical analyses were performed using Stata version 14.0. RESULTS: In total, 14 studies were included, with 120 patients undergoing 153 ablations of 129 solid pancreatic lesions. The STARmed technology was used in seven studies, the Habib system in six studies, and the HybridTherm probe in one study. The pooled technical success rate was 99.0% (I (2): 25.82%). The pooled overall AE rate was 8.0% (I (2): 11.46%). Excluding mild AEs, the pooled rates of serious AEs was 1.0% (I (2): 0%). No mortality related to the procedure was reported. CONCLUSION: The present pooled analysis confirms the safety and feasibility of EUS-RFA

    Gastric peroral endoscopic pyloromyotomy for refractory gastroparesis: a systematic review of early outcomes with pooled analysis

    Get PDF
    Background and Aims: Gastroparesis (GP) is a chronic debilitating condition. Prior pyloric-targeted procedures are either invasive or have questionable efficacy. Gastric peroral pyloromyotomy (G-POEM) has been proposed as a minimally invasive approach. We performed a pooled analysis to evaluate the efficacy and safety of G-POEM for GP. Methods: Electronic databases (Medline, Scopus, EMBASE) were searched up to January 2019. Studies including patients who underwent G-POEM for GP were eligible. Procedural, clinical, and safety outcomes were assessed by pooling data with a random- or fixed-effect model according to the degree of heterogeneity to obtain a proportion with a 95% confidence interval. Results: Ten studies were eligible for inclusion (292 patients), and 2 of the 10 studies were prospective. Seven studies were performed in the United States, 2 in France, and 1 in China. Endoscopic pyloromyotomy was feasible in all patients. Significant symptomatic improvement was achieved after 83.9% of procedures (mean follow-up, 7.8 ± 5.5 months). When comparing the mean values of pre- and postprocedural scintigraphic evolution, there was a significant decrease of the residual percentage at 2 and 4 hours. The overall adverse events rate was 6.8%. Conclusions: G-POEM appears to be a promising approach for GP in terms of safety and efficacy outcomes in the short term

    Cost-effectiveness of artificial intelligence for screening colonoscopy: a modelling study

    Get PDF
    Background: Artificial intelligence (AI) tools increase detection of precancerous polyps during colonoscopy and might contribute to long-term colorectal cancer prevention. The aim of the study was to investigate the incremental effect of the implementation of AI detection tools in screening colonoscopy on colorectal cancer incidence and mortality, and the cost-effectiveness of such tools. Methods: We conducted Markov model microsimulation of using colonoscopy with and without AI for colorectal cancer screening for individuals at average risk (no personal or family history of colorectal cancer, adenomas, inflammatory bowel disease, or hereditary colorectal cancer syndrome). We ran the microsimulation in a hypothetical cohort of 100 000 individuals in the USA aged 50–100 years. The primary analysis investigated screening colonoscopy with versus without AI every 10 years starting at age 50 years and finishing at age 80 years, with follow-up until age 100 years, assuming 60% screening population uptake. In secondary analyses, we modelled once-in-life screening colonoscopy at age 65 years in adults aged 50–79 years at average risk for colorectal cancer. Post-polypectomy surveillance followed the simplified current guideline. Costs of AI tools and cost for downstream treatment of screening detected disease were estimated with 3% annual discount rates. The main outcome measures included the incremental effect of AI-assisted colonoscopy versus standard (no-AI) colonoscopy on colorectal cancer incidence and mortality, and cost-effectiveness of screening projected for the average risk screening US population. Findings: In the primary analyses, compared with no screening, the relative reduction of colorectal cancer incidence with screening colonoscopy without AI tools was 44·2% and with screening colonoscopy with AI tools was 48·9% (4·8% incremental gain). Compared with no screening, the relative reduction in colorectal cancer mortality with screening colonoscopy with no AI was 48·7% and with screening colonoscopy with AI was 52·3% (3·6% incremental gain). AI detection tools decreased the discounted costs per screened individual from 3400to3400 to 3343 (a saving of 57perindividual).Resultsweresimilarinthesecondaryanalysesmodellingonceinlifecolonoscopy.AttheUSpopulationlevel,theimplementationofAIdetectionduringscreeningcolonoscopyresultedinyearlyadditionalpreventionof7194colorectalcancercasesand2089relateddeaths,andayearlysavingofUS57 per individual). Results were similar in the secondary analyses modelling once-in-life colonoscopy. At the US population level, the implementation of AI detection during screening colonoscopy resulted in yearly additional prevention of 7194 colorectal cancer cases and 2089 related deaths, and a yearly saving of US290 million. Interpretation: Our findings suggest that implementation of AI detection tools in screening colonoscopy is a cost-saving strategy to further prevent colorectal cancer incidence and mortality. Funding: European Commission and Japan Society of Promotion of Science

    Mechanisms of aquaporin-4 vesicular trafficking in mammalian cells

    Get PDF
    The aquaporin-4 (AQP4) water channel is abundantly expressed in the glial cells of the central nervous system and facilitates brain swelling following diverse insults, such as traumatic injury or stroke. Lack of specific and therapeutic AQP4 inhibitors highlights the need to explore alternative routes to control the water permeability of glial cell membranes. The cell surface abundance of AQP4 in mammalian cells fluctuates rapidly in response to changes in oxygen levels and tonicity, suggesting a role for vesicular trafficking in its translocation to and from the cell surface. However, the molecular mechanisms of AQP4 trafficking are not fully elucidated. In this work, early and recycling endosomes were investigated as likely candidates of rapid AQP4 translocation together with changes in cytoskeletal dynamics. In transiently transfected HEK293 cells a significant amount of AQP-eGFP colocalised with mCherry-Rab5-positive early endosomes and mCherry-Rab11-positive recycling endosomes. When exposed to hypotonic conditions, AQP4-eGFP rapidly translocated from intracellular vesicles to the cell surface. Co-expression of dominant negative forms of the mCherry-Rab5 and -Rab11 with AQP4-eGFP prevented hypotonicity-induced AQP4-eGFP trafficking and led to concentration at the cell surface or intracellular vesicles respectively. Use of endocytosis inhibiting drugs indicated that AQP4 internalisation was dynamin-dependent. Cytoskeleton dynamics-modifying drugs also affected AQP4 translocation to and from the cell surface. AQP4 trafficking mechanisms were validated in primary human astrocytes, which express high levels of endogenous AQP4. The results highlight the role of early and recycling endosomes and cytoskeletal dynamics in AQP4 translocation in response to hypotonic and hypoxic stress and suggest continuous cycling of AQP4 between intracellular vesicles and the cell surface under physiological conditions
    corecore