36 research outputs found

    Mitral annular calcification predicts immediate results of percutaneous transvenous mitral commissurotomy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Many previous studies have evaluated the impact of mitral valve (MV) deformity scores on the percutaneous transvenous mitral commissurotomy (PTMC) outcome in patients with mitral stenosis; however, the relationship between mitral annulus calcification (MAC) and the PTMC result has not yet been established. The current study aimed to investigate whether MAC could independently influence the immediate result of PTMC.</p> <p>Methods</p> <p>Of all patients undergoing PTMC in our institution between April 2005 and November 2009, we included 87 patients (28.7%male, mean ± SD age = 42.8 ± 12.6 years) with rheumatic mitral stenosis who had additional data on the echocardiographic evaluation of MAC along with MV leaflets morphology. Echocardiographic assessments were repeated up to six weeks after PTMC to evaluate the immediate PTMC outcome. The frequency of the optimal PTMC result (secondary MV area > = 1.5 cm<sup>2 </sup>with > = 25% increase and without final mitral regurgitation grade > 2) was compared between two groups of patients with MAC (n = 17) and those without MAC (n = 70).</p> <p>Results</p> <p>The optimal result was obtained in 55 (63.2%) patients, whereas the result was suboptimal in 32 (36.8%) patients due to insufficient MV area increase in 31(96.9%) subjects and post-procedure mitral regurgitation grade > 2 in 1(3.1%). The rate of optimal PTMC results was less in patients with MAC in comparison to those without MAC (29.4% vs.71.4%). After adjustments for possible confounders such as age and leaflets morphological subcomponents (thickening, mobility, calcification, and subvalvular thickening), MAC remained a significant negative predictor of a suboptimal PTMC result (odds ratio = 0.154; 95%CI = 0.038-0.626, p value = 0.009) together with leaflet thickening (odds ratio = 0.214; 95%CI = 0.060-0.770, p value = 0.018).</p> <p>Conclusions</p> <p>MAC appeared to independently influence the immediate result of PTMC; therefore, mitral annulus evaluation may be considered in the echocardiographic assessment of the mitral apparatus prior to PTMC.</p

    Improved Right Ventricular Systolic Function After Cardiac Resynchronization Therapy in Patients With Heart Failure

    Get PDF
    Background Since the introduction of cardiac resynchronization therapy (CRT) to improve left ventricular function, the effect of CRT on the right ventricle in patients with heart failure has not been well described. Methods We evaluated the effect of CRT on right ventricular systolic function in 20 patients (80% men; mean [SD] age, 58.5 [9.8] y) with cardiomyopathy and right ventricular systolic dysfunction (New York Heart Association class III or IV, left ventricular ejection fraction ≤35%, and QRS interval ≥120 ms). The median follow-up time was 15 months. Right ventricular systolic function, defined as a tricuspid annular plane systolic excursion (TAPSE) index of 16 mm or less, was evaluated in patients before and after CRT. Results Twelve (60%) patients had ischemic cardiomyopathy, and 12 (60%) patients had left bundle branch block detected using surface electrocardiogram. The mean (SD) QRS duration was 160.5 (24.4) ms. From before CRT to the time of follow-up after CRT, the mean (SD) ejection fraction increased significantly from 22.5% (5.6%) to 29.4% (7.4%) (P \u3c .001). The mean (SD) TAPSE index also increased significantly from 13.70 (1.78) mm to 16.50 (4.77) mm (P = .018). Eleven (55%) patients showed improved right ventricular systolic function (TAPSE ≥16 mm) after CRT. Patients with a favorable right ventricular response to CRT were significantly older (64.6 [8.2] y vs 53.6 [8.4] y, respectively) and more likely to have nonischemic origin of cardiomyopathy than were patients with unimproved right ventricular function (66.7% vs 18.2%, respectively). Conclusion Our findings indicate that CRT is associated with improved right ventricular systolic function in patients with heart failure and right ventricular systolic dysfunction. Patients with nonischemic heart disease more often show improved right ventricular function after CRT

    Role of Ventral Hippocampal GABA&lt;sub&gt;A&lt;/sub&gt; and NMDA Receptors in the Anxiolytic Effect of Carbamazepine in Rats Using the Elevated Plus Maze Test

    Full text link
    &lt;i&gt;Background:&lt;/i&gt; The successful use of antiepileptic drugs to treat a wide range of nonepileptic disorders led us to evaluate the potential efficacy of carbamazepine (CBZ) in anxiety disorders. Anxiety may be related to the imbalance between γ-aminobutyric acid (GABA) and glutamate neurotransmitters, systems that are also involved in the CBZ effects. We investigated the role of these systems in the ventral hippocampus (VH) and their interactions with the CBZ effect on anxiety-like behavior in rats using the elevated plus maze. &lt;i&gt;Methods:&lt;/i&gt; Animals received GABAergic and NMDA agents in a volume of 1 μl/rat, which was injected into the VH (0.5 μl for each side) 60 min after receiving systemic administration of CBZ. The test sessions took place 10 min later. &lt;i&gt;Results:&lt;/i&gt; The systemic administration of CBZ increased the percentage of open arm time (%OAT) at the dose of 40 mg/kg, which is representative of an anxiolytic response. Intra-VH injection of the GABA&lt;sub&gt;A&lt;/sub&gt; receptor agonist muscimol (0.25–1 μg/rat) in the absence or presence of an ineffective dose of CBZ (30 mg/kg) did not show any significant changes in the parameters of anxiety-like behavior. The administration of GABA&lt;sub&gt;A&lt;/sub&gt; receptor antagonist bicuculline by itself decreased %OAT at a dose of 1 μg/rat, indicating possible anxiogenic effect. The antagonist (0.75 and 1 μg/rat) also decreased CBZ response. A microinjection of NMDA (0.125 and 0.25 μg/rat) decreased %OAT, which was reversed by the administration of CBZ (40 mg/kg). This indicates interaction between the two drugs. However, the NMDA receptor antagonist DAP-5 (1 μg/rat) significantly increased %OAT, but combined with the lower dose of CBZ (30 mg/kg), it did not trigger any response on anxiety-like parameters. &lt;i&gt;Conclusion:&lt;/i&gt; Both GABAergic and NMDA systems in the VH play a role in modulation of anxiety-like behavior of rats. The anxiolytic-like effects of CBZ seem to be mediated, at least in part, through an interaction with GABA&lt;sub&gt;A&lt;/sub&gt; and NMDA systems in the VH.</jats:p

    Anxiolytic-like Effects and Increase in Locomotor Activity Induced by Infusions of NMDA into the Ventral Hippocampus in Rat: Interaction with GABAergic System

    No full text
    Introduction: In this study, we investigated the role of N-Methyl-D-Aspartate (NMDA) receptors in the ventral hippocampus (VH) and their possible interactions with GABAA system on anxiety-like behaviors. Methods: We used an elevated-plus maze test (EPM) to assess anxiety-like behaviors and locomotor activity in male Wistar rats. Results: The results showed that intra-VH infusions of different doses of NMDA (0.25 and 0.5 μg/rat) increased locomotor activity, and also induced anxiolytic-like behaviors, as revealed by a tendency to increase percentage of open arm time (%OAT), and a significant increase in percentage of open arm entries (%OAE). The results also showed that intra-VH infusions of muscimol (0.5 and 1 μg/rat) or bicuculline (0.5 and 1 μg/rat) did not significantly affect anxiety-like behaviors, but bicuculline at dose of 1 μg/rat increased locomotor activity. Intra-VH co-infusions of muscimol (0.5 μg/rat) along with low doses of NMDA (0.0625 and 0.125 μg/rat) showed a tendency to increase %OAT, %OAE and locomotor activity however, no interaction was observed between the drugs. Interestingly, intra-VH co-infusions of bicuculline (0.5 μg/rat) along with effective doses of NMDA (0.25 and 0.5 μg/rat) decreased %OAT, %OAE and locomotor activity, and a significant interaction between two drugs was observed. Discussion: It can be concluded that GABAergic system may mediate the anxiolytic-like effects and increase in locomotor activity induced by NMDA in the VH

    A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect : cardiovascular topics

    No full text
    OBJECTIVES: Transcatheter closure of a secundum atrial septal defect (ASD II) has become an effective alternative for surgical treatment. In this study we evaluated the correlation between the two-dimensional transoesophageal echocardiographic (2D TEE) sizing of ASDs and the actual diameter of occluders in patients undergoing device closure. METHODS: The records of 54 patients who underwent transcatheter ASD closure were reviewed. ASD characteristics and maximum defect diameter were evaluated using preprocedure 2D TEE images. Appropriate device size was determined by the balloon sizing method, which measures the balloon occlusive diameter (BOD) via TEE and fluoroscopy. ASD closure was performed under continuous TEE monitoring using the Amplatzer occluder in all patients. RESULTS: The mean of the TEE-derived maximum defect diameter was significantly lower than the mean of the BOD (17.8 ± 4.5 vs 22.1 ± 5.1 mm; p < 0.001) and the mean size of the implanted occluder device (17.8 ± 4.5 vs 23.3 ± 5.1 mm; p < 0.001). However, a good correlation was found between the TEE-derived defect size and the BOD (BOD = 0.898 × TEE defect size + 6.212, R = 0.824; p < 0.001) and between the TEE measurement and the final size of the implanted Amplatzer (device size = 0.928 × TEE defect size + 6.853, R = 0.822; p < 0.001). CONCLUSIONS: 2D TEE may provide a good equation to predict the BOD or the size of the occluder device; however, further studies are needed to investigate whether it is feasible to perform transcatheter ASD occlusion without balloon sizing

    Transcatheter Closure of Patent Ductus Arteriosus: Initial Study on Echocardiographic Estimation of Device Size

    No full text
    Background: Transcatheter occlusion of the patent ductus arteriosus (PDA) is a minimally invasive treatment. The appropriate device size is chosen based on the angiographic measurement of the PDA. The current study aimed to assess the relationship between the transthoracic echocardiographic (TTE) measurements of the PDA prior to the occlusion procedure and the actual size of the deployed device.Methods: We reviewed the available records of 7 patients (2 male) who underwent the procedure at our institution (mean age: 21 ± 12.7 years, range: 7 to 46 years). PDA closure was performed successfully using the Amplatzer Duct Occluder (n = 5) and its Chinese copycat, Cardi-O-Fix Occluder (n = 2).Results: The TTE measurement of the aortic end diameter of the PDA showed a good linear regression correlation with the size of the implanted duct occluder [duct occluder size = 0.543 + (0.941× TTE measured diameter), R = 0.907; p value ≤ 0.01].Conclusion: TTE can provide a good estimation of the size of the Amplatzer duct occluder
    corecore