3,416 research outputs found

    Implantable RF-coiled chip packaging

    Get PDF
    In this paper, we present an embedded chip integration technology that utilizes silicon housings and flexible parylene radio frequency (RF) coils. As a demonstration of this technology, a flexible parylene RF coil has been integrated with an RF identification (RFID) chip. The coil has an inductance of 16 μH, with two layers of metal completely encapsulated in parylene-C. The functionality of the embedded chip is verified using an RFID reader module. Accelerated-lifetime soak testing has been performed in saline, and the results show that the silicon chip is well protected and the lifetime of our parylene-encapsulated RF coil at 37 °C is more than 20 years

    Constraining cosmologies with fundamental constants I. Quintessence and K-Essence

    Full text link
    Many cosmological models invoke rolling scalar fields to account for the observed acceleration of the expansion of the universe. These theories generally include a potential V(phi) which is a function of the scalar field phi. Although V(phi) can be represented by a very diverse set of functions, recent work has shown the under some conditions, such as the slow roll conditions, the equation of state parameter w is either independent of the form of V(phi) or is part of family of solutions with only a few parameters. In realistic models of this type the scalar field couples to other sectors of the model leading to possibly observable changes in the fundamental constants such as the fine structure constant alpha and the proton to electron mass ratio mu. This paper explores the limits this puts on the validity of various cosmologies that invoke rolling scalar fields. We find that the limit on the variation of mu puts significant constraints on the product of a cosmological parameter w+1 times a new physics parameter zeta_mu^2, the coupling constant between mu and the rolling scalar field. Even when the cosmologies are restricted to very slow roll conditions either the value of zeta_mu must be at the lower end of or less than its expected values or the value of w+1 must be restricted to values vanishingly close to 0. This implies that either the rolling scalar field is very weakly coupled with the electromagnetic field, small zeta_mu, very weakly coupled with gravity, w+1 ~ 0 or both. These results stress that adherence to the measured invariance in mu is a very significant test of the validity of any proposed cosmology and any new physics it requires. The limits on the variation of mu also produces a significant tension with the reported changes in the value of alpha.Comment: Accepted for publication in MNRAS 10 pages, 6 figure

    Floating-disk parylene microvalve for self-regulating biomedical flow controls

    Get PDF
    A novel self-regulating parylene micro valve is presented in this paper with potential applications for biomedical flow controls. Featuring a free-floating bendable valve disk and two-level valve seat, this surface-micromachined polymeric valve accomplishes miniature pressure/flow rate regulation in a band-pass profile stand-alone without the need of power sources or active actuation. Experimental data of underwater testing results have successfully demonstrated that the microfabricated in-channel valve can regulate water flow at 0-80 mmHg and 0-10 µL/min pressure/flow rate level, which is perfectly suitable for biomedical and lab-on-a-chip applications. For example, such biocompatible microvalve can be incorporated in ocular implants for control of eye fluid drainage to fulfill intraocular pressure (IOP) regulation in glaucoma patients

    Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors

    Get PDF
    This paper presents an implantable parylene-based wireless pressure sensor for biomedical pressure sensing applications specifically designed for continuous intraocular pressure (IOP) monitoring in glaucoma patients. It has an electrical LC tank resonant circuit formed by an integrated capacitor and an inductor coil to facilitate passive wireless sensing using an external interrogating coil connected to a readout unit. Two surface-micromachined sensor designs incorporating variable capacitor and variable capacitor/inductor resonant circuits have been implemented to realize the pressure-sensitive components. The sensor is monolithically microfabricated by exploiting parylene as a biocompatible structural material in a suitable form factor for minimally invasive intraocular implantation. Pressure responses of the microsensor have been characterized to demonstrate its high pressure sensitivity (> 7000 ppm/mmHg) in both sensor designs, which confirms the feasibility of pressure sensing with smaller than 1 mmHg of resolution for practical biomedical applications. A six-month animal study verifies the in vivo bioefficacy and biostability of the implant in the intraocular environment with no surgical or postoperative complications. Preliminary ex vivo experimental results verify the IOP sensing feasibility of such device. This sensor will ultimately be implanted at the pars plana or on the iris of the eye to fulfill continuous, convenient, direct, and faithful IOP monitoring

    Technical pre-analytical effects on the clinical biochemistry of Atlantic salmon (Salmo salar L.)

    Get PDF
    Clinical biochemistry has long been utilized in human and veterinary medicine as a vital diagnostic tool, but despite occasional studies showing its usefulness in monitoring health status in Atlantic salmon (Salmo salar L.), it has not yet been widely utilized within the aquaculture industry. This is due, in part, to a lack of an agreed protocol for collection and processing of blood prior to analysis. Moreover, while the analytical phase of clinical biochemistry is well controlled, there is a growing understanding that technical pre-analytical variables can influence analyte concentrations or activities. In addition, post-analytical interpretation of treatment effects is variable in the literature, thus making the true effect of sample treatment hard to evaluate. Therefore, a number of pre-analytical treatments have been investigated to examine their effect on analyte concentrations and activities. In addition, reference ranges for salmon plasma biochemical analytes have been established to inform veterinary practitioners and the aquaculture industry of the importance of clinical biochemistry in health and disease monitoring. Furthermore, a standardized protocol for blood collection has been proposed

    Implantable Unpowered Parylene MEMS Intraocular Pressure Sensor

    Get PDF
    This paper presents the first implantable, unpowered, parylene-based micro-electro-mechanical-systems (MEMS) pressure sensor for intraocular pressure (IOP) sensing. From in situ mechanical deformation of the compliant structures, this sensor registers pressure variations without power consumption/transduction. Micromachined high-aspect-ratio thin-walled tubes in different geometric layouts are exploited to obtain a high-sensitivity pressure response. An integrated packaging method has been successfully developed to realize suture-less implantation of the device. In vitro testing results have demonstrated that the IOP sensor can achieve 0.67 degree/mmHg angular sensitivity with a spiral-tube design, 3.43 µm/mmHg lateral sensitivity with a long-armed-tube design, and 0.38 µm/mmHg longitudinal sensitivity with a serpentine-tube design. This IOP sensor is designed to be implanted in the anterior chamber of the eye and anchored directly on the iris so that, under incident visible light, the pressure response of the implant can be directly observed from outside the eye, which enables faithful and unpowered IOP monitoring in glaucoma patient

    Corrosion Behavior of Parylene-Metal-Parylene Thin Films in Saline

    Get PDF
    In this paper, we study the corrosion behavior of parylene-metal-parylene thin films using accelerated-lifetime soak tests. The samples under test are thin film resistors with a 200 nm layer of Au sandwiched by parylene-C on both sides, fabricated with parylene-metal skin technology. The samples are tested in hot saline both passively and actively, and different failure modes are observed using optical and electron-beam metrologies. Bubbles and delamination are first seen in the samples after 2 days of soaking under passive conditions, and followed by metal corrosion. While under active conditions, either bubbles or parylene breakdowns are observed depending on the thickness of parylene packaging. These results contribute to a better understanding of the failure mechanisms of parylene packaging in body fluids

    Pretreatment with beta-blockers and the frequency of hypokalemia in patients with acute chest pain

    Get PDF
    Plasma potassium concentration was measured at admission in 1234 patients who presented with acute chest pain. One hundred and ninety five patients were on P blockers before admission. The potassium concentrations of patients admitted early (within four hours of onsetof symptoms) were compared with those admitted later (4-18 hours after onset of symptoms). There was a transient fall in plasma potassium concentrations in patients not pre-treated with , B blockers. This was not seen in patients who had been on P blockers before admission. Nonselective, B blockers were more effective than cardioselective agents in maintaining concentrationsof plasma potassium. These findings suggest a mechanism for the beneficial effects of ,B blockers on morbidity and mortality in acute myocardial infarction

    Evidence for a Z < 8 Origin of the Source Subtracted Near Infrared Background

    Full text link
    This letter extends our previous fluctuation analysis of the near infrared background at 1.6 microns to the 1.1 micron (F110W) image of the Hubble Ultra Deep field. When all detectable sources are removed the ratio of fluctuation power in the two images is consistent with the ratio expected for faint, z<8, sources, and is inconsistent with the expected ratio for galaxies with z>8. We also use numerically redshifted model galaxy spectral energy distributions for 50 and 10 million year old galaxies to predict the expected fluctuation power at 3.6 microns and 4.5 microns to compare with recent Spitzer observations. The predicted fluctuation power for galaxies at z = 0-12 matches the observed Spitzer fluctuation power while the predicted power for z>13 galaxies is much higher than the observed values. As was found in the 1.6 micron (F160W) analysis the fluctuation power in the source subtracted F110W image is two orders of magnitude below the power in the image with all sources present. This leads to the conclusion that the 0.8--1.8 micron near infrared background is due to resolved galaxies in the redshift range z<8, with the majority of power in the redshift range of 0.5--1.5.Comment: Accepted for publication in the Astrophysical Journa
    corecore