386 research outputs found

    Catastrophic stroke in a patient with left ventricular non-compaction

    Get PDF
    We present the case of a 32-year-old man who presented with a remote history of chest pain and was diagnosed with non-compaction cardiomyopathy on echocardiography. On presentation, he was relatively asymptomatic with normal cardiac function. Unfortunately, he presented 1 year later with a catastrophic embolic stroke

    Coronary flow velocity reserve and inflammatory markers in living kidney donors

    Get PDF
    Background: Coronary microvascular dysfunction is prevalent in chronic kidney disease (CKD), and may contribute to the development of myocardial dysfunction in CKD. Coronary flow velocity reserve (CFVR) is a marker of coronary microvascular function and falls with increasing CKD stage. Living kidney donors have renal function consistent with early stage CKD and concern has been raised about their cardiovascular risk. No studies to date have investigated the presence of coronary microvascular dysfunction in living kidney donors. Methods: 25 healthy controls and 23 living kidney donors were recruited and underwent assessment with transthoracic echocardiography, Doppler CFVR, myocardial contrast echocardiography and serum multiplex immunoassay panels. Results: Doppler CFVR was significantly reduced in living kidney donors compared to controls (mean CFVR 3.4 ± 0.7 vs 3.8 ± 0.6, mean difference 0.4 95% confidence interval 0.03–0.8, p =.036). Quantitative myocardial contrast echocardiography showed a trend towards reduced coronary flow reserve in living kidney donors. Compared to controls, living kidney donors had higher serum high sensitivity C reactive peptide (hsCRP) and lower levels of uromodulin. Conclusions: This is the first study of CFVR in living kidney donors. We have shown that the modest drop in estimated glomerular filtration rate in living kidney donors is associated with lower values of Doppler CFVR compared to controls, suggesting that isolated reductions in renal function may lead to altered microvascular function. The increase in hsCRP and reduction in uromodulin suggests that chronic subclinical inflammation may contribute to altered microvascular function in this population.</p

    Stress echocardiography in coronary artery disease: a practical guideline from the British Society of Echocardiography

    Get PDF
    Stress echocardiography is an established technique for assessing coronary artery disease. It has primarily been used for the diagnosis and assessment of patients presenting with chest pain in whom there is an intermediate probability of coronary artery disease. In addition, it is used for risk stratification and to guide revascularisation in patients with known ischaemic heart disease. Although cardiac computed tomography has recently been recommended in the United Kingdom as the first-line investigation in patients presenting for the first time with atypical or typical angina, stress echocardiography continues to have an important role in the assessment of patients with lesions of uncertain functional significance and patients with known ischaemic heart disease who represent with chest pain. In this guideline from the British Society of Echocardiography, the indications and recommended protocols are outlined for the assessment of ischaemic heart disease by stress echocardiography

    Long-term outcomes after stress echocardiography in real world practice: five-year follow-up of the UK Evarest study

    Get PDF
    Aims: Stress echocardiography is widely used to assess patients with chest pain. The clinical value of a positive or negative test result to inform on likely longer-term outcomes when applied in real-world practice across a healthcare system has not been previously reported. Methods and results: Five thousand five hundred and three patients recruited across 32 UK NHS hospitals between 2018 and 2022, participating in the EVAREST/BSE-NSTEP prospective cohort study, with data on medical outcomes up to 2023 available from NHS England were included in the analysis. Stress echocardiography results were related to outcomes, including death, procedures, hospital admissions, and relevant cardiovascular diagnoses, based on Kaplan–Meier analysis and Cox proportional hazard ratios (HRs). Median follow-up was 829 days (interquartile range 224–1434). A positive stress echocardiogram was associated with a greater risk of myocardial infarction [HR 2.71, 95% confidence interval (CI) 1.73–4.24, P < 0.001] and a composite endpoint of cardiac-related mortality and myocardial infarction (HR 2.03, 95% CI 1.41–2.93, P < 0.001). Hazard ratios increased with ischaemic burden. A negative stress echocardiogram identified an event-free ‘warranty period’ of at least 5 years in patients with no prior history of coronary artery disease and 4 years for those with disease. Conclusion: In real-world practice, the degree of myocardial ischaemia recorded by clinicians at stress echocardiography correctly categorizes risk of future events over the next 5 years. Reporting a stress echocardiogram as negative correctly identifies patients with no greater than a background risk of cardiovascular events over a similar time period

    Diagnostic accuracy of handheld cardiac ultrasound device for assessment of left ventricular structure and function: systematic review and meta-analysis

    Get PDF
    Objective: Handheld ultrasound devices (HUD) has diagnostic value in the assessment of patients with suspected left ventricular (LV) dysfunction. This meta-analysis evaluates the diagnostic ability of HUD compared with transthoracic echocardiography (TTE) and assesses the importance of operator experience.  Methods: MEDLINE and EMBASE databases were searched in October 2020. Diagnostic studies using HUD and TTE imaging to determine LV dysfunction were included. Pooled sensitivities and specificities, and summary receiver operating characteristic curves were used to determine the diagnostic ability of HUD and evaluate the impact of operator experience on test accuracy.  Results: Thirty-three studies with 6062 participants were included in the meta-analysis. Experienced operators could predict reduced LV ejection fraction (LVEF), wall motion abnormality (WMA), LV dilatation and LV hypertrophy with pooled sensitivities of 88%, 85%, 89% and 85%, respectively, and pooled specificities of 96%, 95%, 98% and 91%, respectively. Non-experienced operators are able to detect cardiac abnormalities with reasonable sensitivity and specificity. There was a significant difference in the diagnostic accuracy between experienced and inexperienced users in LV dilatation, LVEF (moderate/severe) and WMA. The diagnostic OR for LVEF (moderate/severe), LV dilatation and WMA in an experienced hand was 276 (95% CI 58 to 1320), 225 (95% CI 87 to 578) and 90 (95% CI 31 to 265), respectively, compared with 41 (95% CI 18 to 94), 45 (95% CI 16 to 123) and 28 (95% CI 20 to 41), respectively, for inexperienced users.  Conclusion: This meta-analysis is the first to establish HUD as a powerful modality for predicting LV size and function. Experienced operators are able to accurately diagnose cardiac disease using HUD. A cautious, supervised approach should be implemented when imaging is performed by inexperienced users. This study provides a strong rationale for considering HUD as an auxiliary tool to physical examination in secondary care, to aid clinical decision making when considering referral for TTE

    Changes in coronary disease management decisions in real-world practice between 2015 and 2023: insights from the EVAREST/BSE-NSTEP observational study

    Get PDF
    Aims: To assess the real-world impact of updated clinical guidelines and literature on the management of patients undergoing stress echocardiography for the assessment of inducible ischaemia across a national health service. Methods and results: A total of 13 819 patients from 32 UK hospitals, referred for stress echocardiography between 2015 and 2023, were analysed across two phases: phase 1 (2015–2020) and phase 2 (2020–2023). Follow-up data for 1 year was available for 4920 participants through NHS Digital. Patients in phase 2 were younger and presented with a higher cardiovascular risk profile, although sex distribution remained similar across phases. There was an observed reduction in invasive angiography referrals within 1 year following a positive stress echocardiogram (P < 0.01), which appeared to be attributed to changes in the management of patients with moderate ischaemia (3–4 segments; P < 0.01). For those who did receive invasive assessment, there were no changes in intervention rate (P = 0.27), regardless of ischaemic burden. This trend was most evident in centres performing a higher volume of stress echocardiograms. Conclusion: Coronary disease management pathways have changed within the UK and fewer patients with moderate ischaemia are undergoing invasive coronary angiography. However, coronary intervention rates are unchanged, suggesting that stress echocardiography is being used to improve patient selection for invasive procedures while minimizing unnecessary referrals. Future work will assess if this reduction in angiography referrals is maintained long term, and if there are any effects on patient outcomes

    Natural History of Patients with Ischemia and No Obstructive Coronary Artery Disease: The CIAO-ISCHEMIA Study

    Get PDF
    Background: Ischemia with no obstructive coronary artery disease (INOCA) is common and has an adverse prognosis. We set out to describe the natural history of symptoms and ischemia in INOCA. Methods: CIAO-ISCHEMIA (Changes in Ischemia and Angina over One year in ISCHEMIA trial screen failures with INOCA) was an international cohort study conducted from 2014-2019 involving angina assessments (Seattle Angina Questionnaire [SAQ]) and stress echocardiograms 1-year apart. This was an ancillary study that included patients with history of angina who were not randomized in the ISCHEMIA trial. Stress-induced wall motion abnormalities were determined by an echocardiographic core laboratory blinded to symptoms, coronary artery disease (CAD) status and test timing. Medical therapy was at the discretion of treating physicians. The primary outcome was the correlation between changes in SAQ Angina Frequency score and change in echocardiographic ischemia. We also analyzed predictors of 1-year changes in both angina and ischemia, and compared CIAO participants with ISCHEMIA participants with obstructive CAD who had stress echocardiography before enrollment, as CIAO participants did. Results: INOCA participants in CIAO were more often female (66% of 208 vs. 26% of 865 ISCHEMIA participants with obstructive CAD, p\u3c0.001), but the magnitude of ischemia was similar (median 4 ischemic segments [IQR 3-5] both groups). Ischemia and angina were not significantly correlated at enrollment in CIAO (p=0.46) or ISCHEMIA stress echocardiography participants (p=0.35). At 1 year, the stress echocardiogram was normal in half of CIAO participants and 23% had moderate or severe ischemia (≥3 ischemic segments). Angina improved in 43% and worsened in 14%. Change in ischemia over one year was not significantly correlated with change in angina (rho=0.029). Conclusions: Improvement in ischemia and improvement in angina were common in INOCA, but not correlated. Our INOCA cohort had a similar degree of inducible wall motion abnormalities to concurrently enrolled ISCHEMIA participants with obstructive CAD. Our results highlight the complex nature of INOCA pathophysiology and the multifactorial nature of angina

    Real world hospital costs following stress echocardiography in the UK: a costing study from the EVAREST/BSE-NSTEP multi-entre study

    Get PDF
    Background: Stress echocardiography is widely used to detect coronary artery disease, but little evidence on downstream hospital costs in real-world practice is available. We examined how stress echocardiography accuracy and downstream hospital costs vary across NHS hospitals and identifed key factors that afect costs to help inform future clinical planning and guidelines. Methods: Data on 7636 patients recruited from 31 NHS hospitals within the UK between 2014 and 2020 as part of EVAREST/BSE-NSTEP clinical study, were used. Data included all diagnostic tests, procedures, and hospital admissions for 12 months after a stress echocardiogram and were costed using the NHS national unit costs. A decision tree was built to illustrate the clinical pathway and estimate average downstream hospital costs. Multi-level regression analysis was performed to identify variation in accuracy and costs at both patient, procedural, and hospital level. Linear regression and extrapolation were used to estimate annual hospital cost-savings associated with increasing predictive accuracy at hospital and national level. Results: Stress echocardiography accuracy varied with patient, hospital and operator characteristics. Hypertension, presence of wall motion abnormalities and higher number of hospital cardiology outpatient attendances annually reduced accuracy, adjusted odds ratio of 0.78 (95% CI 0.65 to 0.93), 0.27 (95% CI 0.15 to 0.48), 0.99 (95% CI 0.98 to 0.99) respectively, whereas a prior myocardial infarction, angiotensin receptor blocker medication, and greater operator experience increased accuracy, adjusted odds ratio of 1.77 (95% CI 1.34 to 2.33), 1.64 (95% CI 1.22 to 2.22), and 1.06 (95% CI 1.02 to 1.09) respectively. Average downstream costs were £646 per patient (SD 1796) with signifcant variation across hospitals. The average downstream costs between the 31 hospitals varied from £384–1730 per patient. False positive and false negative tests were associated with average downstream costs of £1446 (SD £601) and £4192 (SD 3332) respectively, driven by increased non-elective hospital admissions, adjusted odds ratio 2.48 (95% CI 1.08 to 5.66), 21.06 (95% CI 10.41 to 42.59) respectively. We estimated that an increase in accuracy by 1 percentage point could save the NHS in the UK £3.2 million annually. Conclusion: This study provides real-world evidence of downstream costs associated with stress echocardiography practice in the UK and estimates how improvements in accuracy could impact healthcare expenditure in the NHS. A real-world downstream costing approach could be adopted more widely in evaluation of imaging tests and interventions to refect actual value for money and support realistic planning
    corecore