76 research outputs found

    Artificial Neural Networks for reconstruction of energy losses in dead materials between barrel LAr and Tile calorimeters: exploration and results

    Get PDF
    In the course of computational experiments with Monte-Carlo events for ATLAS Combined Test Beam 2004 setup Artificial Neural Networks (ANN) technique was applied for reconstruction of energy losses in dead materials between barrel LAr and Tile calorimeters (Edm). The constructed ANN procedures exploit as their input vectors the information content of different sets of variables (parameters) which describe particular features of the hadronic shower of an event in ATLAS calorimeters. It was shown that application of ANN procedures allows one to reach 40% reduction of the Edm reconstruction error compared to the conventional procedure used in ATLAS collaboration. Impact of various features of a shower on the precision of EdmEdm reconstruction is presented in detail. It was found that longitudinal shower profile information brings greater improvement in EdmEdm reconstruction accuracy than cell energies information in LAr3 and Tile1 samplings

    Study of the Transition Effect with the ATLAS Tile Calorimeter

    Get PDF
    With the aim to establish the electromagnetic energy scale of the ATLAS Tile calorimeter and understanding the performance of the calorimeter to electrons 12% of modules have been exposed in electron beams with various energies. On a basis of the obtained electromagnetic calibration constants we have determined the e/mip values in dependence of the absorber thickness using different beam incident angles. We have observed the transition effect (e/mip < 1) and, for the first time, its behaviour as a function of the absorber thickness --- the e/mip ratio decreases logarithmically when the absorber thickness increases this is well described by the GEANT4 version 6.2 Monte Carlo simulation. These results are important for precision electromagnetic energy scale determination for the ATLAS Tile calorimeter

    Electromagnetic Cell Level Calibration for ATLAS Tile Calorimeter Modules

    Get PDF
    We have determined the electromagnetic calibration constants of 11% TileCal modules exposed to electron beams with incident angles of 20 and 90 degrees. The gain of all the calorimeter cells have been pre-equalized using the radioactive Cs-source that will be also used in situ. The average values for these modules are equal to: for the flat filter method 1.154+/-0.002 pC/GeV and 1.192+/-0.002 pC/GeV for 20 and 90 degrees, for the fit method 1.040+/-0.002 pC/GeV and 1.068+/-0.003 pC/GeV, respectively. These average values for all cells of calibrated modules agree with the weighted average calibration constants for separate modules within the errors. Using the individual calibration constants for every module the RMS spread value of constants will be 1.9+/-0.1 %. In the case of the global constant this value will be 2.6+/-0.1 %. Finally, we present the global constants which should be used for the electromagnetic calibration of the ATLAS Tile hadronic calorimeter data in the ATHENA framework. These constants are equal to 1.15 pC/GeV in the case of the flat filter method and 1.04 pC/GeV for the fit one

    Measurement of the beauty production cross-section in 350 GeV/c π\pi^- -Cu interactions

    Get PDF
    Using a sample of 10810^8 triggered events, produced in π\pi^---\,Cu interactions at 350~GeV/c/c, we have identified 26 beauty events. The estimated background in this sample is 0.6±0.60.6 \pm 0.6 events. From these data, assuming a linear A-dependence, we measure a beauty production cross-section integrated over all xFx_F of 5.7+1.31.1 (stat.)+0.60.5 (syst.) 5.7 {+1.3 \atop -1.1}~{\mathrm {(stat.)}} {+0.6 \atop -0.5}~{\mathrm {(syst.)}}~nb/N

    Response of the ATLAS tile calorimeter prototype to muons

    Get PDF
    A study of high energy muons traversing the ATLAS hadron Tile calorimeter in the barrel region in the energy range between 10 and 300~GeV is presented. Both test beam experimental data and Monte Carlo simulations are given and show good agreement. The Tile calorimeter capability of detecting isolated muons over the above energy range is demonstrated. A signal to background ratio of about 10 is expected for the nominal LHC luminosity (1034cm2sec110^{34} cm^{-2} sec^{-1}). The photoelectron statistics effect in the muon shape response is shown. The e/mip ratio is found to be 0.81±0.03 0.81 \pm 0.03; the e/μ\mu ratio is in the range 0.91 - 0.97. The energy loss of a muon in the calorimeter, dominated by the energy lost in the absorber, can be correlated to the energy loss in the active material. This correlation allows one to correct on an event by event basis the muon energy loss in the calorimeter and therefore reduce the low energy tails in the muon momentum distribution

    Observation of vertex factorisation breaking in central pp interactions

    Get PDF
    Central \pipi events produced in pp interactions are studied in terms of correlations between the outgoing protons. It is observed there is more ρ0\rho^{0}(770) and \fmeson production in reactions where the outgoing protons %fastest and slowest particles in the laboratory frame are on opposite sides of the beam. This effect is not attributable to the trigger or the experimental acceptance, and suggests that the vertices do not factorise

    Evaluation of Fermi Read-out of the ATLAS Tilecal Prototype

    Get PDF
    Prototypes of the \fermi{} system have been used to read out a prototype of the \atlas{} hadron calorimeter in a beam test at the CERN SPS. The \fermi{} read-out system, using a compressor and a 40 MHz sampling ADC, is compared to a standard charge integrating read-out by measuring the energy resolution of the calorimeter separately with the two systems on the same events. Signal processing techniques have been designed to optimize the treatment of \fermi{} data. The resulting energy resolution is better than the one obtained with the standard read-out

    Results from a combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter

    Get PDF
    The first combined test of an electromagnetic liquid argon accordion calorimeter and a hadronic scintillating-tile calorimeter was carried out at the CERN SPS. These devices are prototypes of the barrel calorimeter of the future ATLAS experiment at the LHC. The energy resolution of pions in the energy range from 20 to 300~GeV at an incident angle θ\theta of about 11^\circ is well-described by the expression \sigma/E = ((46.5 \pm 6.0)\%/\sqrt{E} +(1.2 \pm 0.3)\%) \oplus (3.2 \pm 0.4)~\mbox{GeV}/E. Shower profiles, shower leakage, and the angular resolution of hadronic showers were also studied
    corecore