57 research outputs found
TSH-CHECK-1 test: diagnostic accuracy and potential application to initiating treatment for hypothyroidism in patients on anti-tuberculosis drugs.
Thyroid-stimulating hormone (TSH) promotes expression of thyroid hormones which are essential for metabolism, growth, and development. Second-line drugs to treat tuberculosis (TB) can cause hypothyroidism by suppressing thyroid hormone synthesis. Therefore, TSH levels are routinely measured in TB patients receiving second-line drugs, and thyroxin treatment is initiated where indicated. However, standard TSH tests are technically demanding for many low-resource settings where TB is prevalent; a simple and inexpensive test is urgently needed
Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies: The PRISMA-DTA Statement.
This is the final version of the article. Available from American Medical Association via the DOI in this record.Importance: Systematic reviews of diagnostic test accuracy synthesize data from primary diagnostic studies that have evaluated the accuracy of 1 or more index tests against a reference standard, provide estimates of test performance, allow comparisons of the accuracy of different tests, and facilitate the identification of sources of variability in test accuracy. Objective: To develop the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guideline as a stand-alone extension of the PRISMA statement. Modifications to the PRISMA statement reflect the specific requirements for reporting of systematic reviews and meta-analyses of diagnostic test accuracy studies and the abstracts for these reviews. Design: Established standards from the Enhancing the Quality and Transparency of Health Research (EQUATOR) Network were followed for the development of the guideline. The original PRISMA statement was used as a framework on which to modify and add items. A group of 24 multidisciplinary experts used a systematic review of articles on existing reporting guidelines and methods, a 3-round Delphi process, a consensus meeting, pilot testing, and iterative refinement to develop the PRISMA diagnostic test accuracy guideline. The final version of the PRISMA diagnostic test accuracy guideline checklist was approved by the group. Findings: The systematic review (produced 64 items) and the Delphi process (provided feedback on 7 proposed items; 1 item was later split into 2 items) identified 71 potentially relevant items for consideration. The Delphi process reduced these to 60 items that were discussed at the consensus meeting. Following the meeting, pilot testing and iterative feedback were used to generate the 27-item PRISMA diagnostic test accuracy checklist. To reflect specific or optimal contemporary systematic review methods for diagnostic test accuracy, 8 of the 27 original PRISMA items were left unchanged, 17 were modified, 2 were added, and 2 were omitted. Conclusions and Relevance: The 27-item PRISMA diagnostic test accuracy checklist provides specific guidance for reporting of systematic reviews. The PRISMA diagnostic test accuracy guideline can facilitate the transparent reporting of reviews, and may assist in the evaluation of validity and applicability, enhance replicability of reviews, and make the results from systematic reviews of diagnostic test accuracy studies more useful.The research was supported by grant 375751 from the Canadian Institute for Health Research; funding from the Canadian Agency for Drugs and Technologies in Health; funding from the Standards for Reporting of Diagnostic Accuracy Studies Group; funding from the University of Ottawa Department of Radiology Research Stipend Program; and funding from the National Institute for Health Research Collaboration for Leadership in Applied Health Research and Care South West Peninsula
Estimates of sensitivity and specificity can be biased when reporting the results of the second test in a screening trial conducted in series
Quality and Reporting of Diagnostic Accuracy Studies in TB, HIV and Malaria: Evaluation Using QUADAS and STARD Standards
BackgroundPoor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV.MethodsWe identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004–2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively.FindingsNinety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of[...] and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD
Reducing decision errors in the paired comparison of the diagnostic accuracy of screening tests with Gaussian outcomes
Methodological Deficits in Diagnostic Research Using ‘-Omics’ Technologies: Evaluation of the QUADOMICS Tool and Quality of Recently Published Studies
Background: QUADOMICS is an adaptation of QUADAS (a quality assessment tool for use in systematic reviews of diagnostic accuracy studies), which takes into account the particular challenges presented by '-omics' based technologies. Our primary objective was to evaluate the applicability and consistency of QUADOMICS. Subsequently we evaluated and describe the methodological quality of a sample of recently published studies using the tool. Methodology/Principal Findings: 45'-omics'- based diagnostic studies were identified by systematic search of Pubmed using suitable MeSH terms (>Genomics>, >Sensitivity and specificity>, >Diagnosis>). Three investigators independently assessed the quality of the articles using QUADOMICS and met to compare observations and generate a consensus. Consistency and applicability was assessed by comparing each reviewer's original rating with the consensus. Methodological quality was described using the consensus rating. Agreement was above 80% for all three reviewers. Four items presented difficulties with application, mostly due to the lack of a clearly defined gold standard. Methodological quality of our sample was poor; studies met roughly half of the applied criteria (mean ± sd, 54.7±18.4°%). Few studies were carried out in a population that mirrored the clinical situation in which the test would be used in practice, (6, 13.3%);none described patient recruitment sufficiently; and less than half described clinical and physiological factors that might influence the biomarker profile (20, 44.4%). Conclusions: The QUADOMICS tool can consistently be applied to diagnostic '-omics' studies presently published in biomedical journals. A substantial proportion of reports in this research field fail to address design issues that are fundamental to make inferences relevant for patient care. © 2010 Parker et al.This work was supported by the Spanish Agency for Health Technology Assessment, Exp PI06/90311, Instituto de Salud Carlos III and CIBER en Epidemiología y Salud Pública (CIBERESP) in SpainPeer Reviewe
Magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries: protocol for a systematic review of diagnostic accuracy
Background
Adult brachial plexus injuries (BPI) are becoming more common. The reconstruction and prognosis of pre-ganglionic injuries (root avulsions) are different to other types of BPI injury. Preoperative magnetic resonance imaging (MRI) is being used to identify root avulsions, but the evidence from studies of its diagnostic accuracy are conflicting. Therefore, a systematic review is needed to address uncertainty about the accuracy of MRI and to guide future research.
Methods
We will conduct a systematic search of electronic databases alongside reference tracking. We will include studies of adults with traumatic BPI which report the accuracy of preoperative MRI (index test) against surgical exploration of the roots of the brachial plexus (reference standard) for detecting either of the two target conditions (any root avulsion or any pseudomeningocoele as a surrogate marker of root avulsion). We will exclude case reports, articles considering bilateral injuries and studies where the number of true positives, false positives, false negatives and true negatives cannot be derived. The methodological quality of the included studies will be assessed using a tailored version of the QUADAS-2 tool. Where possible, a bivariate model will be used for meta-analysis to obtain summary sensitivities and specificities for both target conditions. We will investigate heterogeneity in the performance of MRI according to field strength and the risk of bias if data permits.
Discussion
This review will summarise the current diagnostic accuracy of MRI for adult BPI, identify shortcomings and gaps in the literature and so help to guide future research
Performance of four HRP-2/pLDH combination rapid diagnostic tests and field microscopy as screening tests for malaria in pregnancy in Indonesia: a cross-sectional study
Biomarkers of a five-domain translational substrate for schizophrenia and schizoaffective psychosis
- …
