3,585 research outputs found

    New Data on the Archaeological Obsidians of the Banat and Transylvania

    Get PDF
    Società per la Preistoria e Protostoria della Regione Friuli-Venezia Giulia, Quaderno 12 - ISSN

    Drift velocity and gain in argon- and xenon-based mixtures

    Full text link
    We present measurements of drift velocities and gains in gas mixtures based on Ar and Xe, with CO2, CH4, and N2 as quenchers, and compare them with calculations. In particular, we show the dependence of Ar- and Xe-CO2 drift velocities and gains on the amount of nitrogen contamination in the gas, which in real experiments may build up through leaks. A quantification of the Penning mechanism which contributes to the Townsend coefficients of a given gas mixture is proposed.Comment: 11 pages, 7 figures, accepted for publication in Nucl.Instrum.Meth. A. Data files available at http://www-alice.gsi.de/tr

    A Comparative Numerical Study on GEM, MHSP and MSGC

    Full text link
    In this work, we have tried to develop a detailed understanding of the physical processes occurring in those variants of Micro Pattern Gas Detectors (MPGDs) that share micro hole and micro strip geometry, like GEM, MHSP and MSGC etc. Some of the important and fundamental characteristics of these detectors such as gain, transparency, efficiency and their operational dependence on different device parameters have been estimated following detailed numerical simulation of the detector dynamics. We have used a relatively new simulation framework developed especially for the MPGDs that combines packages such as GARFIELD, neBEM, MAGBOLTZ and HEED. The results compare closely with the available experimental data. This suggests the efficacy of the framework to model the intricacies of these micro-structured detectors in addition to providing insight into their inherent complex dynamical processes

    Charge Transfer and Charge Broadening of GEM Structures in High Magnetic Fields

    Full text link
    We report on measurements of charge transfer in GEM structures in high magnetic fields. These were performed in the framework of the R&D work for a Time Projection Chamber at a future Linear Collider. A small test chamber has been installed into the aperture of a superconducting magnet with the GEM structures mounted perpendicular to the B field direction. The charge transfer is derived from the electrical currents monitored during irradiation with an 55{}^{55}Fe source. No severe loss of primary ionisation charge is observed, but an improved ion feedback suppression is achieved for high magnetic fields. Additionally, the width of the charge cloud released by individual 55{}^{55}Fe photons is measured using a finely segmented strip readout after the triple GEM structure. Charge widths between 0.3 and 0.5 mm RMS are observed, which originate from the charge broadening inside the GEM readout. This charge broadening is only partly suppressed at high magnetic fields.Comment: 11 pages, 9 figure

    lHuman cytotoxic T lymphocytes with reduced sensitivity to Fas-induced apoptosis

    Get PDF
    Effector-memory T cells expressing Fas (Apo-1/CD95) are switched to an apoptotic program by cross-linking with Fas-ligand (FasL). Consequently, tumors that express FasL can induce apoptosis of infiltrating Fas-positive T lymphocytes and subdue any antitumor host immune response. Since Epstein-Barr virus (EBV)-associated tumors such as Hodgkin lymphoma (HL) and nasopharyngeal carcinoma (NPC) express FasL, we determined whether EBV-specific cytotoxic T lymphocytes (EBV-CTLs) could be modified to resist this evasion strategy. We show that long-term down-modulation of Fas can be achieved in EBV-CTLs by transduction with small interfering RNA (siRNA) encoded in a retrovirus. Modified T cells resisted Fas/FasL-mediated apoptosis compared with control cells and showed minimal cleavage of the caspase3 substrate poly(ADP-ribose) polymerase (PARP) protein after Fas engagement. Prolonged Fas stimulation selected a uniformly Fas(low) and FasL resistant population. Removal of responsiveness to this single death signal had no other discernible effects on EBV-CTLs. In particular, it did not lead to their autonomous growth since the modified EBV-CTLs remained polyclonal, and their survival and proliferation retained dependence on antigen-specific stimulation and on the presence of other physiologic growth signals. EBV-CTLs with knocked down Fas should have a selective functional and survival advantage over unmodified EBV-CTLs in the presence of tumors expressing FasL and may be of value for adoptive cellular therapy. (c) 2005 by The American Society of Hematology

    Development of a Time Projection Chamber Using Gas Electron Multipliers (GEM-TPC)

    Get PDF
    We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%), Ar(70%)-C2H6(30%) and CF4). Detection efficiency of 99%, and spatial resolution of 79 μ\mum in the pad-row direction and 313 μ\mum in the drift direction were achieved. The test results show that the GEM-TPC meets the requirements for high energy heavy ion collision experiments. The configuration and performance of the GEM-TPC are described.Comment: 18 pages, 12 figures, published online in Nucl. Instr. and Meth.

    Simulation of VUV electroluminescence in micropattern gaseous detectors: the case of GEM and MHSP

    Full text link
    Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting mainly in the VUV region. The photons can provide signal readout if appropriate photosensors are used. Micropattern gaseous detectors are good candidates for signal amplification in high background and/or low rate experiments due to their high electroluminescence yields and radiopurity. In this work, the VUV light responses of the Gas Electron Multiplier and of the Micro-Hole Strip Plate, working with pure xenon, are simulated and studied in detail using a new and versatile C++ toolkit. It is shown that the solid angle subtended by a photosensor placed below the microstructures depends on the operating conditions. The obtained absolute EL yields, determined for different gas pressures and as functions of the applied voltage, are compared with those determined experimentally.Comment: Accepted for publication in Journal of Instrumentatio
    corecore